BEGA 51100.1 LED Recessed Ceiling Downlight Instruction Manual
- June 13, 2024
- BEGA
Table of Contents
BEGA 51100.1 LED Recessed Ceiling Downlight Instruction Manual
Dimension
Application
Ceiling luminaire downlight · indoor luminaire with symmetrical wide beam light distribution. Ready-to-connect set of 3 including external phase- dimmable LED power supply unit and connection cables between the luminaires. For installation in suspended ceilings of 3-18mm in interior applications.
Product description
Set of 3 ready-to-connect recessed ceiling luminaire downlights including
external power supply unit
Luminaire housing made of die-cast zinc
finish Colour velvet white
Reflector surface made of pure aluminium
Fixing is achieved by using
2 fastening springs
Recessed opening ø 68mm
Required installation depth 48mm
Connection cable with 2-pole plug connector between luminaires and external
LED power supply unit (see sketch)
External LED power supply unit
220-240 V y 50-60 Hz
Dimmable via a leading-edge or trailing-edge dimmer
Safety class II
– Conformity mark
Weight: 0.6 kg
This product contains light sources of energy efficiency class(es) E
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend
separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Module connected wattage 4 W
Luminaire connected wattage 16 W
Rated temperature ta=25 °C
Ambient temperature ta max=30 °C
51 100.1K27
Module designation 3x LED-1208/927
Colour temperature 2700 K
Colour rendering index CRI >90
Module luminous flux 1620 lm
Luminaire luminous flux 950 lm
Luminaire luminous efficiency 59,4 lm/W
51 100.1K3
Module designation 3x LED-1208/930
Colour temperature 3000 K
Colour rendering index CRI >90
Module luminous flux 1740 lm
Luminaire luminous flux 1020 lm
Luminaire luminous efficiency 63,8 lm/W
Light technique
Symmetrical wide beam light distribution Half beam angle 30°
Installation
Luminaire housing and external LED power supply unit must not be covered by any heat insulating materials.
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
The ready-to-connect set of recessed ceiling luminaires includes an external phasedimmable LED power supply unit and connection cables with 2-pole plug connector between the luminaires and the LED power supply unit.
Installation in suspended ceilings:
For each luminaire, a recessed opening of 68 mm with a minimum depth of 48 mm
is required.
The minimal thickness of the ceiling panel must be 3 mm and must not be greater than 18 mm. A ceiling panel with less than 3 mm thickness must be reinforced on the reverse.
he electrical connection must be made on site in the appropriate safety class on the LED power supply unit connecting cable. A distribution box must be used.
Ensure the correct assignment of the connecting cable. Establish the mains connection on the brown (L) and blue (N) wires. Guide the LED power supply unit and connection cable with distribution boxes through the ceiling opening and deposit them in the suspended ceiling.
Make sure that the plug connectors between connection cables and distribution
boxes on the suspended ceiling are connected correctly before connecting the
recessed luminaires.
The luminaires are interlinked in a series connection.
IMPORTANT: Make sure that the series circuit is closed via the plug with wire jumper in the distribution box of the last luminaire.
Alternatively, plug this plug with wire jumper into the distribution box
socket of the last luminaire. Connect the plug of the first recessed luminaire
to the integrated socket of the first distribution box until the latch
engages.
Proceed with additional luminaires in the same way.
Cover the recessed opening with the stop ring of the luminaire housing.
The luminaire housing is then fixed in the recessed opening via two springs.
Compress the fastening springs of the luminaire housing on both sides and
slide the luminaire housing into the recessed opening.
The fastening springs lock into place behind the ceiling panel.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Close the luminaire.
Spares
LED power supply unit DEV-0431/700
Connecting cable 62 001 256
Connecting cable 62 001 258
Distributor 64 000 636
Plug with wire jumper 64 000 637
LED module 2700 K LED-1208/927
LED module 3000 K LED-1208/930
Retaining spring LED component 73 005 597
LED component 75 004 495 K27
LED component 75 004 495 K3
Reflector 76 002 019
BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden · info@bega.com · www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>