LIGHT SKY F1700WB Energy Saving Outdoor Beam Light
SAFETY INFORMATION
- This lighting fixture is for professional use only – it is not for household use.
INSTALLATION
Make sure all parts for fixing the projector are in a good state of repair.
Make sure the point of anchorage is stable before positioning the projector.
The safety chain must be properly hooked onto the fitting and secured to the
framework. When suspending the fixture, ensure that the supporting structure
and all hardware used can hold at least 10 times the weight of all the devices
they support.
Mounting surface and fire protection
Please do not install the fixture onto the combustible surface.
Keep all combustible materials at least 20 cm away from the fixture.
Ensure a minimum clearance of 0.2m around the cooling fans and ventilation. Do
not expose the front glass to sunlight or other strong light sources from any
angle. Lenses can focus the sun’s rays inside the fixture, creating a
potential fire hazard.
MAINTENACE
Before starting any maintenance work or cleaning the projector, cut off power
from the main supply. After switching off, do not remove any parts of the
fitting, to avoid getting burnt for at least 30 minutes. After this time the
likelihood of the lamp exploding is virtually nill.
The fitting is designed to hold in any splinters produced by a lamp exploding.
The lenses must be mounted and, if visibly Damaged, they have to be replaced
with genuine spares.
Lamp
The fitting mounts a high-pressure lamp that needs an external.
Immediately replace the lamp if damaged or deformed by heat.
The light source in this fixture shall be replaced by the manufacturer or its
service agent or similar qualification.
Always disconnect from mains before replacing the lamp.
The products referred to in this manual conform to the European Community
Directives to which they are subject:
Low Voltage 2014/35/EU
Electromagnetic Compatibility 2014/30/EU
TECHNICAL INFORMATION
-
Power supplies available :
– 198-264V~ 50/60Hz 11A -
Power :
– 2000W PF≥0.98 -
Lamp :
– Light source :OSRAM lok-it HTI 1700PS
– Lamp power:1700W
– Average life:750H
– Color Temperature :
2700K-6500K, Linear CTO adjustment. -
Luminous flux output:37000LM
-
Zoom Range:4°- 45°
-
CRI: Ra ≥ 90
-
Ballast:Electrical ballast。
-
Reflector :
– Double Reflector Cup design, German optical coating process. -
Framing Shutter system:
– 4 facet & 4 blades framing shutters modules, framing shutter system can be rotated 90°. -
Frost :
– 1° and 20 ° can be combined. -
Dimming :
– 16 Bit, 0-100% linear dimming. -
S trobe :
– 1-9Hz synchronization, pulse, random stroboscopic. -
Control Mode :
DMX512, RDM, Art-Net, Wireless DMX512(optional). -
X/Y Travel:540°/270°
-
X/Y Resolution:2.11°/1.05°
-
X/Y Speed:2.5S/1.5S
-
Channel : Standard 25CH
-
I set :
– built-in long-life battery, can set address without power connection. -
Software upgrade :
– Upgrade via USB interface. -
Display Menu:
– The display panel adopts a 2.8-inch color LCD
screen, which is used in both Chinese and English languages to facilitate quick operation and browsing menus.
– Display board can record devices using time, and show the device’s temperature, channel data, and software version. -
Working Mode :
– Silent, Standard, High brightness three modes. -
Features :
– Remote Control Lamp Switch On/Off, automatically reduce the lamp power when the Shutter is Off. -
Temperature control :
– Intelligent temperature control, can automatically adjust the speed of the cooling fan and overheat protection. -
Error alarm :
– Automatic alarming for fixture error. -
Structure :
– plastic cover parts are made of engineering plastic PA66
+ GF, with fire-proof, noise reduction, impact resistance, high-temperature resistance, and anti-aging characteristics. -
The vertical direction of the use of hidden locking devices, convenient transportation, and maintenance.
-
IP RATE: IP22
-
Lighting Size:503X324X878MM
-
Box Size:960X570X395MM
N. W.:41kg, G.W.:46kg -
Fly case Size (1PCS):
765X610X970MM
N. W.:41kg, G.W.:85.5kg
distance, spot diameter and illumination diagram(Beam model)
ATTACHMENT AND BODY SIZE
Installing the projector-
The projector can be installed on the floor resting on special rubber feet, on
a truss or on the ceiling or wall. WARNING: with the exception of when the
projector is positioned on the floor, the safety rope must be fitted. This
must be securely fixed to the support structure of the projector and then
connected to the base handle.
Make sure all parts for fixing the projector are in a good state of repair.
Make sure the point of anchorage is stable before positioning the projector.
When suspending the fixture, ensure that the supporting structure and all
hardware used can hold at least 10 times the weight of all the devices they
support. Wire color-coding and power
connections:
- connection to the electricity mains must be carried out by a qualified electrical installer.
- After doing the above operation and making sure all the devices had been installed with natural operate, press the power switch to check whether every -thing is working normally.
-
Please use the round 3 or 5-pin XLR plugs &sockets offered by menu facture to connect the first projector’s output to the second projector’ input and connect the second projector’s output to the
third projector’s input. And in the same way the rest, eventually, connect the last projector’s output, all the projectors are together. -
The projectors control signal output or input by using the 3 or 5-pin XLR pug and socket.If need to lengthen the communication cable, please make sure both side of 3 or 5-pin plug is one to one
(one to one, two to two, three to three). Otherwise, the communication cable will be interrupted. The communication cable is a 2-cord screened cable with 75Ω resistance with each core is at least a 0.5mm diameter.(Caution: All the inside leading wire of 3 or 5-pin XLR plug couldn’t touch each other or plinth). -
Recommend using the DMX signal terminator for the installation to avoid the electronic noise damage the digital control signal. Simply speaking, DMX terminator is an XLR connector with a 120Ω 1/2W resistor connected across pin 2 and 3. Which is then plugged into the output socket on the last projector in the hain.Refer to the connection.
CONTROL PANEL
- Press the switch.The projector starts resetting the effects. At the same time,the following information scrolls on the display
(please refer to the actual material)
MENY SETTING
Main menu | Ⅰ menu | ” menu | Ⅲ menu | ⅠV menu |
---|
DMX SETTING
|
→
|
Address
|
→
|
1-512
| | | |
Channel mode| →| Standard(25)| | | |
Input mode| →| DMX| | | |
DMX State|
→
| Blackout| | | |
Hold| | | |
Info
|
→
|
Fixture times
|
→
| Power on time| | 0 – 99999H| |
Lamp on time| | 0 – 99999H| |
All time| | 0 – 99999H| |
Temperatures| →| Lamp TEMP| | | |
Fan speed
|
→
| Head fan 1| | | |
Head fan 2| | | |
Lamp fan 1| | | |
Lamp fan 2| | | |
Lamp fan 3| | | |
Lamp fan 4| | | |
Framing fan| | | |
Power fan| | | |
Fan voltage
| | Head fan 1| | | |
| Head fan 2| | | |
| Lamp fan 1| | | |
| Lamp fan 2| | | |
| Lamp fan 3| | | |
| Lamp fan 4| | | |
| Framing fan| | | |
| Power fan| | | |
RDM info
|
→
| UID:0x3888XXXXXXXX| | | |
Manufactory| | | |
Device Label| | | |
DMX live
|
→
| 1.Pan|
→
| 0 – 255| |
2.Pan fine| 0 – 255| |
3.Tilt| 0 – 255| |
4.Tilt Fine| 0 – 255| |
5.P/T speed| 0 – 255| |
6.Functions| 0 – 255| |
7.Strobe| 0 – 255| |
8.Dimmer| 0 – 255| |
9.Dimmer fine| 0 – 255| |
10.CTO| 0 – 255| |
11.Colour wheel| 0 – 255| |
12.Blade UP| 0 – 255| |
13.Blade DW| 0 – 255| |
14.Blade LF| 0 – 255| |
Main menu| | Ⅰ menu| | ” menu| | Ⅲ menu| | ⅠV menu
---|---|---|---|---|---|---|---|---
Info
|
→
|
DMX live
|
→
| 15.Blade RF| | 0 – 255| |
16.Framing Rot.| 0 – 255| |
17.Framing Mac.| 0 – 255| |
18.Framing Mac.Z.| 0 – 255| |
19.Zoom| 0 – 255| |
20.Focus| 0 – 255| |
21.Focus fine| 0 – 255| |
22.Auto Fin.| 0 – 255| |
23.Auto Dis.| 0 – 255| |
24.Frost1| 0 – 255| |
25.Frost2| 0 – 255| |
Version info
|
→
| Display|
→
| VX.XXX| |
Pan/Tilt| VX.XXX| |
Color module| VX.XXX| |
Framing module| VX.XXX| |
Zoom module| VX.XXX| |
FanDrv| VX.XXX| |
Ballast info
|
→
| Input voltage| | XXXV| |
Output voltage| | XXXV| |
Input current| | XXXA| |
Output Power| | XXXW| |
Internal.T| | XXX℃| |
External.T| | XXX℃| |
Running state
|
→
| Error| |
OK| |
Fault| |
Person
|
→
|
Pan/Tilt
|
→
|
PT swap
|
→
| OFF| |
ON| |
Pan invert
| OFF| |
ON| |
Tilt invert
| OFF| |
ON| |
Power mode
|
→
| 1200W mode| | | |
1400W mode| | | |
1700W mode| | | |
Display
|
→
|
Language
| | English| |
Chinese| |
Backlight time
| Always| |
Auto (30S)| |
Intensity| 0 – 100| |
Rotation
| Normal| |
Rotate 180| |
Auto| |
Main menu| | Ⅰ menu| | ” menu| | Ⅲ menu| | ⅠV menu
---|---|---|---|---|---|---|---|---
Manual
|
→
|
Manual Control
|
→
| 1.Pan| | 0 – 255| |
2.Pan fine| 0 – 255| |
3.Tilt| 0 – 255| |
4.Tilt| 0 – 255| |
5.P/T speed| 0 – 255| |
6.Functions| 0 – 255| |
7.Strobe| 0 – 255| |
8.Dimmer| 0 – 255| |
9.Dimmer fine| 0 – 255| |
10.CTO| 0 – 255| |
11.Colour wheel| 0 – 255| |
12.Blade UP| 0 – 255| |
13.Blade DW| 0 – 255| |
14.Blade LF| 0 – 255| |
15.Blade RF| 0 – 255| |
16.Framing Rot| 0 – 255| |
17.Framing Mac.| 0 – 255| |
18.Framing Mac.Z| 0 – 255| |
19.Zoom| 0 – 255| |
20.Focus| 0 – 255| |
21.Focus fine| 0 – 255| |
22.Auto Fin| 0 – 255| |
23.Auto Dis| 0 – 255| |
24.Frost1| 0 – 255| |
25.Frost2| 0 – 255| |
Lamp Switch|
→
| OFF| | | |
ON| | | |
Reset
|
→
| Pan/Tilt reset| | | |
Dimmer reset| | | |
Color reset| | | |
Framing reset| | | |
Focus reset| | | |
Total reset| | | |
Test
|
→
| Test all|
→
| Test| | | |
Test pan/tilt| Test| | | |
Test effects| Test| | | |
Service
|
→
|
Fixture state
|
→
| Memory IC|
→
| OK/ Reset/ Error| |
Angle Sensor| OK/ Reset/ Error| |
Pan Encodeer| OK/ Reset/ Error| |
Main menu
| |
Ⅰ menu
| |
” menu
| |
Ⅲ menu
| |
ⅠV menu
---|---|---|---|---|---|---|---|---
Service
|
→
|
Fixture state
|
→
| Pan Drive IC|
→
| OK/ Reset/ Error| |
Tilt Encoder| OK/ Reset/ Error| |
Tilt Drive IC| OK/ Reset/ Error| |
Pan| OK/ Reset/ Error| |
Tilt| OK/ Reset/ Error| |
CTO| OK/ Reset/ Error| |
Colour wheel| OK/ Reset/ Error| |
Zoom| OK/ Reset/ Error| |
Focus| OK/ Reset/ Error| |
Framing Rot.| OK/ Reset/ Error| |
Adjust
| →| Pan|
→
| 0 – 255| |
| Tilt| 0 – 255| |
| Strobe 1| 0 – 255| |
| Strobe 2| 0 – 255| |
| CTO| 0 – 255| |
| Colour wheel| 0 – 255| |
| Blade UP| 0 – 255| |
| Blade DW| 0 – 255| |
| Blade LF| 0 – 255| |
| Blade RF| 0 – 255| |
| Framing Rot.| 0 – 255| |
| Zoom| 0 – 255| |
| Focus| 0 – 255| |
| Frost 1| 0 – 255| |
| Frost 2| 0 – 255| |
Factory
|
→
|
Factory Reset
| Pass word
→
| YES / NO| |
Reset timers
|
Pass word
→
| Reset power on timers|
→
|
YES / NO
Reset lamp timers| YES / NO
Reset all timers| YES / NO
Developer
|
Pass word
→
| Correlate lamp| |
Manual Fan Vol| |
Manual Power| |
Manual OR DMX| |
Update
| Pass word
→
|
Simple update
|
→
| Display
Pan/Tilt
Main menu| | Ⅰ menu| | ” menu| | Ⅲ menu| | ⅠV menu
---|---|---|---|---|---|---|---|---
Service
|
→
|
Factory
|
→
|
Update
|
Pass word
→
|
Simple update
|
→
| Color module
Framing module
Zoom module
FANDRV
ALL
Whole update
|
→
| Display
Pan/Tilt
Color module
Framing module
Zoom module
FANDRV
ALL
CHANNEL FUNCTION
Channel| DMX| Percentage| Function| ****
Note
---|---|---|---|---
1| 0-255| 0-100| Pan|
2| 0-255| 0-100| Pan Fine|
3| 0-255| 0-100| Tilt|
4| 0-255| 0-100| Tilt fine|
5| 0-255| 0-100| Pan/Tilt speed|
6
| 0-9| | Reserved (0=default)|
10-14| | RESET ALL|
15-19| | RESET DIMMER SHUTTER|
20-24| | RESET COLOR|
25-29| | RESET FRAMING|
30-34| | RESET PT|
35-39| | RESET ZOOM|
40-44| | LAMP ON|
45-49| | LAMP OFF|
50-54| | Always|
55-59| | Auto (30S)|
60-64| | POWER MODE 1200W|
65-69| | POWER MODE 1400W|
70-74| | POWER MODE 1700W|
75-255| | Reserved|
7
| | | Shutter/ strobe|
0 – 31| | Shutter closed|
32 – 63| | Shutter open (32=default)|
64 – 95| | Strobe-effect from slow to fast|
96 – 127| | Shutter open|
128 – 143| | Opening pulse in sequences from slow to fast|
144 – 159| | Closing pulse in sequences from fast to slow|
160 – 191| | Shutter open|
192 – 223| | Random strobe-effect from slow to fast|
224 – 255| | Shutter open|
8| 0 – 255| 0-100| Dimmer|
9| 0 – 255| 0-100| Dimmer fine|
10| 0 – 255| 0-100| CTO|
11
| | | Colour wheel|
0 – 89| | 0 – 360°|
90 – 99| | OPEN|
100 – 109| | COLOR1|
110 – 119| | COLOR2|
120 – 129| | COLOR3|
130 – 139| | COLOR4|
140 – 149| | COLOR5|
150 – 159| | COLOR6|
160 – 169| | COLOR7|
Channel
| ****
DMX
| Percentage| ****
Function
| ****
Note
---|---|---|---|---
11
| 170 – 179| | COLOR8|
180 – 214| Rotate clockwise, slow to fast|
215 – 249| Rotate counterclockwise, fast to slow|
250 – 255| random color|
12| 0 – 255| 0-100| Blade UP|
13| 0 – 255| 0-100| Blade DW|
14| 0 – 255| 0-100| Blade LF|
15| 0 – 255| 0-100| Blade RF|
16| 0 – 255| 0-100| Framing Rot|
17
| | | Framing Mac|
0 — 10| | N0 function|
11 — 20| | Square|
21 — 30| | Rectangle|
31 — 255| | Reserved|
18| 0 – 255| 0-100| Framing Mac. Zoom|
19| 0 – 255| 0-100| Zoom|
20| 0 – 255| 0-100| Focus|
21| 0 – 255| 0-100| Focus Fine|
22| 0-255| 0-100| Auto Fin|
23
| | | Auto Dis|
0 – 9| | N0 function|
10 — 19| | 10M|
20 — 29| | 15M|
30 — 39| | 20M|
40 — 49| | 30M|
50 — 59| | 40M|
60 — 255| | 50M|
24
| | | Frost 1|
0 – 127| | Minimum atomization to maximum atomization|
128 – 159| | Slow in and fast out from slow to fast|
160 – 191| | Fast in and slow out from slow to fast|
192 – 255| | Slow in Slow out from slow to fast|
25
| | | Frost 2|
0 – 127| | Minimum atomization to maximum atomization|
128 – 159| | Slow in and fast out from slow to fast|
160 – 191| | Fast in and slow out from slow to fast|
192 – 255| | Slow in Slow out from slow to fast|
CIRCUIT CONNECTING DIAGRAM
- In order to ensure the projector could work normally. lt should be kept clean always.It is recommended that thee tans and ventilation inlet should be cleaned every 15 days.The lens and dichroic color filters should also be regularly cleaned to maintain optimum light output. Do not use any type of solvent on dichroic color filters.lt will damage the projector.
- Suggestion: The continued usage of the light doesn’t exceed 4 hours. Or it will shorter the usage of the lamp. Please use the alternative operation to solve this problem.
- please disconnect the power supply when begin to maintain takedown of the light. Please let the parts cool down for 10 minutes at least then begin to install. LF need to replace the lamp, please wait 10 minutes again at least to let the lamp cool down completely or which may be burned down.
- Please inspect the lens or other moving parts’ timing and keep them clear and static. lf find anything damaged or looseness, must change a lamp or fix the lamp in order to avoid the accident.
- The light uses a strong cool system. It is easy for the dirty to be collected. Please do clear the hot-sak one time two weeks at least.
- After you use the light, please check the intake place whether there are some wastepaper, please clean it up,or the windmill will break down and cause a fire.
TROUBLESHOOTING
It is recommended some solutions for some normal troubleshooting. Any
unsanctioned problems should always
be handled by a professional person. Disconnect the power supply before
maintaining the light.
Lamp off
-
Please check if install a suitable lamp.
-
Please check if the connection of the power supply or switch is ok.
-
Please check whether the lamp will reach the end of its life and can explode, please replace the same description
lamp. -
Please measure if the power supply is enough.
-
Please check if the operation is correct. Please wait 30 minutes at least till the lamp cools down enough, then
could connect the power supply, which could be normal work.
Though the light is lighting, it couldn’t accept the control order:
- Please check the start code address and the function option are correct.
- Please check whether the communication control cable is a good connection or if the cable is too long or interrupted.
- Please check if the control system is not valid, check the signal amplifier of the chain connected is valid.
- Please check whether the communication cable is too long or the other equipment is mutually conjugate.
- Please arrange the wire well, Shorter the signal cable, but the high voltage cable and low voltage cable separately.
- Add the signal amplify isolator
- the signal cable is used for the excellent screening doublet (Resistance 759)
DUTY EXONERATIVE AND cOPYRIGHT PROTECTION
-
The lamp belongs to consumer products that is not guaranteed to keep in good repair.
-
Any product broken that didn’t according to the instruction is no guaranteed to keep it in good repair.
The commentary for all the instructions belongs to the supplier in the final. -
No authorization can’t copy.
-
The information in this manual may be changed in the future, the company reserve the right to change
the data without any advice.X`
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>