BEGA 24488 Wall Luminaire Instruction Manual

June 13, 2024
BEGA

BEGA LOGO Technical amendments reserved
Wall luminaire

24488 Wall Luminaire

BEGA 24488 Wall Luminaire - Wall luminaire

Instructions for use

Application

Wall luminaire with asymmetrical light distribution.
For lighting wall and ground surfaces.

**Product description

**

Luminaire made of aluminium alloy, aluminium and stainless steel
BEGA Unidure® coating technology
Safety glass, antireflection-coated Silicone gasket
Reflector surface made of pure aluminium
Mounting plate with 3 elongated holes, Width 6.5 mm · 80 x 145 mm spacing 2 screw cable glands with strain relief for through-wiring power connecting cable ø 7–12 mm
1 screw cable gland closed at the factory with a dummy plug
Connecting terminal 2.5□ with plug connection
Earth conductor connection
BEGA Ultimate Driver®
LED power supply unit 220-240 V x≂ 0/50-60 Hz
DC 176-276 V
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
Safety class I
Protection class IP 66
Dust-tight and protection against strong water jets
Impact strength IK07
Protection against mechanical impacts < 2 joule
– Safety mark
– Conformity mark
Weight: 4.8 kg
This product contains light sources of energy efficiency class(es) C

Dark Sky
The light from this luminaire is directed evenly and highly efficiently onto the surface to be illuminated and emits less than 1 % of the luminaire luminous flux into the upper halfspace of the luminaire.

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Lamp

Module connected wattage| 15.8 W
Luminaire connected wattage| 18.2 W
Rated temperature| ta = 25 °C
Ambient temperature| ta max = 50 °C
24 488 K3
Module designation| LED-1081/830
Colour temperature| 3000 K
Colour rendering index| CRI > 80
Module luminous flux| 3010 lm
Luminaire luminous flux | 2334 lm
Luminaire luminous efficiency
| 128,2 lm / W
24 488 K4
Module designation| LED-1081/840
Colour temperature| 4000 K
Colour rendering index| CRI > 80
Module luminous flux| 3095 lm
Luminaire luminous flux | 2400 lm
Luminaire luminous efficiency
|  131,9 lm / W

  • preliminary data

Installation

Undo hexagon socket head screws (wrench size 3 mm) up to the stop and disassemble the mounting plate.
Pass the power connecting cable through the cable entry in the mounting plate.
The installed black gasket insert is intended for cables ø < 10 mm.
For cables ø 10-12 mm the enclosed grey gasket insert must be used.
In case of through-wiring replace the factory installed dummy plug with the enclosed corresponding gasket insert.
At the same time, use the enclosed synthetic cone-thrust collar between gasket insert and thrust screw (wrench size 22 mm) (see sketch).

BEGA 24488 Wall Luminaire - Installation

Fix the mounting plate with enclosed or any other suitable fixing material onto the mounting surface.
Tighten screw cable gland.
Make earth conductor connection and electrical connection to the connecting terminal (plug connection).
For digital control please use the connecting terminal DA, DA.
In case this terminal is not used the luminaire will be operated at full light output.
Make sure that gasket is positioned correctly.
Push plug into coupler as far as it will go.
Place the luminaire onto the mounting plate and fix it.
Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.

Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.

Spares

Spare glass with frame graphite 25 000 087
LED power supply unit DEV-0312/700
LED module 3000 K LED-1081/830
LED module 4000 K LED-1081/840
Reflector 76 001 960
Gasket wall box 83 001 097
Gasket glass frame 83 002 042

BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
[email protected]
www.bega.com

Documents / Resources

| BEGA 24488 Wall Luminaire [pdf] Instruction Manual
24488, 24488K3, 24488K4, 24488 Wall Luminaire, Wall Luminaire, Luminaire
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BEGA User Manuals

Related Manuals