Application
Track zoom spotlight · Indoor luminaire with adapter for 3-phase EUROSTANDARD
PLUS® track systems.
The spotlight’s optical system can be swivelled and rotated.
Symmetrical light distribution.
To change the light distribution, optical filters are available as accessory
parts.
Changing the half beam angle between 16° and 40° by twisting the lens unit.
Product description
Track zoom spotlight with adapter Cast aluminium luminaire housing, finish
Colour velvet black,
Polycarbonate track adapter with integrated LED power supply unit Optical lens
made of silicate glass
Adjustable metal adapter ring with PMMA lens combination and integrated
optical filter.
LED power supply unit
220-240 V y 50/60 Hz
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
Safety class II
– Conformity mark
Weight: 1.1 kg
This product contains light sources of energy efficiency class(es) F
Lamp
Module connected wattage 25.7 W
Luminaire connected wattage 29.5 W
Rated temperature ta=25 °C
Ambient temperature ta max=35 °C
51 067.5K3
Module designation LED-1145/930
Colour temperature 3000 K
Colour rendering index CRI >90
Module luminous flux 3140 lm
Luminaire luminous flux 1660 lm
Luminaire luminous efficiency 56,3 lm/W
51 067.5K4
Module designation LED-1145/940
Colour temperature 4000 K
Colour rendering index CRI >90
Module luminous flux 3300 lm
Luminaire luminous flux 1744 lm
Luminaire luminous efficiency 59,1 lm/W
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend
separate overvoltage protection components.
You can find them on our website at www.bega.com.
Light technique
Track spot · surface washer with adjustable optical system.
Optical system 0-340° swivel-mounted and ± 310° infinitely rotatable around
the vertical luminaire axis.
Symmetrical light distribution.
Changing the half beam angle between 16° and 40° by twisting the lens unit.
The symmetrical light cone can be changed to a flat beam, symmetrically
diffuse or asymmetrical light distribution for special lighting applications
by replacing the optical filter (standard) – accessoires.
For flat beam light distribution:
Optical filter 13 294
For symmetrically diffuse light distribution:
Optical filter 13 296
For asymmetrical light distribution:
Optical filter 13 295
standard
flat beam
symmetrically diffuse
asymmetrical
The light cone can be adjusted by ±360° by turning the adapter ring with optical filter.
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
The track zoom spotlight with adapter is ready for use in 3-phase
EUROSTANDARD-PLUS® track systems.
No tools are required to attach it to the track.
IMPORTANT:
Ensure that the adapter’s two lateral stays are located on the same side as
the matching guide profile of the track before installing the adapter in the
3-phase EUROSTANDARDPLUS® track system.
To select the phase ( 1 2 3 ) the turning knob on the rear side of the adapter
has to be operated accordingly
Place the surface washer adapter flush on the conductor rail in the desired
position.
Push the two fixing levers on the underside of the adapter to the right until
they click into their end position.
Set the desired LED beam direction by turning and tilting the luminaire
housing.
Please note: One of the two cams on the outer adjustment ring of the
optical lens unit is marked.
The desired half beam angle can be set between 16° and 40° using this cam
marking by turning the adjustment ring.
Move the two fixing levers in opposite directions until they disengage to unlock the adapter.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified personnel using standard tools.
Disconnect the system from the mains.
IMPORTANT: Before disassembling the reflector with the optical lens unit,
the marked cam on the adjustment ring must be turned to the 15° position.
Grasp the internal adapter ring with optical filter by one of its metal tabs
and pull it out of the recess in the luminaire housing against the magnetic
resistance.
Remove the trim ring from the zoom spotlight housing by turning it anti-
clockwise.
Remove the reflector with optical lens unit from the housing.
Remove the LED module. Install the replacement LED module.
Please follow the installation instructions for the new LED module.
Replace the reflector in the luminaire housing.
IMPORTANT: The reflector is installed correctly once the two recesses in
the rear centring disc of the reflector fit over the two bolts on the side of
the LED module.
Ensure that the marked cam on the adjustment ring is pointing in the direction
of the spotlight’s joint axis.
Place the trim ring with scale on the luminaire housing and tighten clockwise.
Please note: The trim ring is only correctly mounted when the 15°
position corresponds to the position of the marked cam.
Reinsert the adapter ring with optical filter into the housing of the zoom
spotlight.
The magnetic housing recess allows the adapter ring to lock precisely into
place.
If the disc combination of the adapter ring with optical filter is defective,
it must be replaced.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Accessories · Optical filters
13 294 flat beam
13 296 symmetrical, diffuse
13 295 asymmetrical
For the accessories a separate instructions for use can be provided upon request.
Spares
Trim ring 20 000 086 B2
LED power supply unit DEV-0438/700i
LED module 3000 K LED-1145/930
LED module 4000 K LED-1145/940
Lens unit 75 004 802
Adapter ring with dispersing filter 75 004 849
BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden · info@bega.com · www.bega.com