BEGA 50256 Indoor Wall Luminaire Instruction Manual

June 12, 2024
BEGA

BEGA 50256 Indoor Wall Luminaire

Product Information

  • Metal housing with a white finish
  • Hand-blown opal glass with a satin matt finish
  • Distance apart: 220 mm
  • LED-Module for mains voltage 220-230 V and 50/60 Hz
  • Weight: 2.0 kg
  • Energy efficiency class(es): G
  • The installation and operation of this luminaire are subject to national safety regulations
  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547
  • Lamp connected wattage: 50 256 K3
  • Rated temperature: Bemessungstemperatur
  • Ambient temperature: Umgebungstemperatur
  • Module designation: 2x LED-0662/930
  • Colour temperature: 3000 K
  • Colour rendering index: Ra > 90
  • Module luminous flux: 1320 lm
  • Luminaire luminous flux: 974 lm
  • Luminaire luminous efficiency: 65.8 lm/W

Product Usage Instructions

  1. Avoid touching the light output opening of the LED directly during installation or relamping.
  2. Lead the mains supply cable through the cable entry of the luminaire base.
  3. Fix the luminaire base with the enclosed or any other suitable fixing material onto the mounting surface.
  4. Ensure to use the gasket rings supplied.
  5. Make an earth conductor connection.
  6. Push silicone sleeves over the lines and make an electrical connection.
  7. During installation, keep in mind that the expansion of glass and metal is different. Allow the glass to expand by placing it into the luminaire base and fixing set screws handtight. Aftertightening the set screws, loosen them for half a turn to allow the glass to move.

Dimension

Wall luminaire for indoor use

Application

  • Wall luminaire · indoor luminaire made of handblown opal glass, satin matt and metal fitting, for all lighting tasks.
  • They are ideal for places where a soft and uniform lighting distribution is required.

Product description

  • Metal housing, finish colour white
  • Hand-blown opal glass, satin matt
  • 2 mounting holes ø 6 mm
  • Distance apart 220 mm
  • 2 cable entries for through-wiring for mains cable up to ø 10.5 mm max. 3 × 1.5@
  • Connecting terminals 2.5@
  • Earth conductor connection
  • LED-Module for mains voltage
  • 220-230 V y 50/60 Hz
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect
  • temperature-sensitive components
  • Safety class I
  • – Safety mark
  • – Conformity mark
  • Weight: 2.0 kg
  • This product contains light sources of energy efficiency class(es) G

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Lamp

  • Luminaire connected wattage 14.8 W

  • Rated temperature ta = 25 °C

  • Ambient temperature ta max = 30 °C
    50 256 K3

  • Module designation 2x LED-0662/930

  • Colour temperature 3000 K

  • Colour rendering index Ra > 90

  • Module luminous flux 1320 lm

  • Luminaire luminous flux 974 lm

  • Luminaire luminous efficiency 65,8 lm / W

Installation

  • LED are high-quality electronic components!
  • Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Lead the mains supply cable through the cable entry of the luminaire base.
  • Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface.
  • Be sure to use the gasket rings supplied.
  • Make earth conductor connection.
  • Push silicone sleeves over the lines and make electrical connection.

Advice:
Expansion of glass and metal is different.
Glass must be allowed to expand.
Place glass into the luminaire base and fix set screws handtight.
After tightening the set screws loosen them for half a turn to allow the glass to move.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.

Replacement of the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire.
  • Please follow the installation instructions for the LED module.
  • Defective glass must be replaced.
  • Close the luminaire.

Spares

Spare glass 11 003 067 .0R G
LED module 3000 K LED-0662/930

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals