Product Information
Parameter | Value |
---|---|
IP Rating | IP44 |
Lamp Module Connected Wattage | 19.2 W |
Luminaire Connected Wattage | 22.4 W |
Rated Temperature | 25-35°C |
Ambient Temperature | 25-35°C |
Module Designation | 3x LED-0425/930 |
Colour Temperature | 3000 K |
Colour Rendering Index (CRI) | CRI > 90 |
Module Luminous Flux | 3165 lm |
Luminaire Luminous Flux | 2170 lm |
Luminaire Luminous Efficiency | 96.9 lm/W |
Product Usage Instructions
- The installation and operation of this luminaire should be carried out in accordance with national safety regulations and by a qualified electrician.
- Do not modify the luminaire without proper authorization as it may void the warranty and the manufacturer will not be liable for any damage caused by improper use or installation.
- For additional protection against overvoltage and transients, it is recommended to use separate overvoltage protection components available on the manufacturer’s website.
- During installation or relamping, avoid touching the light output opening of the LED directly as LEDs are high-quality electronic components.
- When mounting or dismantling, maintain a minimum distance of 450 mm between the removable cap and the wall.
Instructions for use
Application
Wall luminaire · indoor luminaire made of hand-blown opal glass and metal
housing, for all lighting tasks in interior applications. They are ideal for
places where a soft and uniform lighting distribution is required. Luminaire
with a high protection class.
Product description
- Luminaire made of Aluminium, finish Stainless steel
- Hand-blown opal glass 2 elongated fixing holes
- Width 6 mm · 450 mm spacing
- Insulating housing with cable entry for
- mains supply cable up to ø 10,5 mm, max. 3 x 1,5@
- Connection terminal 2.5@
- Earth conductor connection
- LED power supply unit
- 220-240 V x 0/50-60 Hz
- DC 198-280 V
- BEGA Thermal Switch®
- Temporary thermal shutdown to protect temperature-sensitive components
- Safety class I
- Protection class IP 44
- Protected against granular foreign bodies
- ≥ 1 mm and splash water
- Impact strength IK02
- Protection against mechanical impacts < 0.2 joule
- – Safety mark
- – Conformity mark
- Weight: 2.7 kg
- This product contains light sources of energy efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician. The manufacturer accepts no liability for damage
caused by improper use or installation. If subsequent modifications are made
to the luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.
Lamp
- Module connected wattage: 19.2 W
- Luminaire connected wattage: 22.4 W
- Rated temperature: ta = 25 °C
- Ambient temperature: ta max = 35 °C
23 259.2 K3
- Module designation: 3x LED-0425/930
- Colour temperature: 3000 K
- Colour rendering index: CRI > 90
- Module luminous flux: 3165 lm
- Luminaire luminous flux: 2170 lm
- Luminaire luminous efficiency: 96,9 lm / W
Insulation housing
Installation
For mounting and dismantling please keep a minimum distance of 450 mm between the removable cap and the wall. LEDs are high-quality electronic components!Please avoid touching the light output opening of the LED directly during installation or relamping.
Open luminaire:
Loosen knob, remove cap and glass. Drill mounting holes into the mounting
surface – spacing 450 mm.For the mains supply connecting open the insulation
housing – pull open – strip mains supply cable max. 15 mm and lead it into the
insulation housing – see sketch. Make earth conductor connection and
electrical connection. Connect both parts of the insulation housing until they
audibly engage. The outer coating of the cable has to be fully enclosed by the
compression nipple. Fix luminaire with enclosed or any other suitable fixing
material onto the mounting surface. Remove bubble wrap underneath LED module.
Place glass into luminaire housing, close luminaire with the cap and screw in
knob into the cap.
Replacement of the LED module
The designation of the LED module is noted on a label in the luminaire. The
light colour and light output of BEGA replacement modules correspond to those
of the modules originally fitted. The module can be replaced by qualified
persons using standard tools. Disconnect the system. Loosen lateral knob,
remove cap and take out glass. Please follow the installation instructions for
the LED module. Defective glass must be replaced. Insert glass into luminaire
housing, close luminaire with the cap and screw in knob into the cap.
Spare Parts
Spare Part | Part Number |
---|---|
Spare Glass | 11 002 949 .1R G |
LED Power Supply Unit | DEV-0352/1000 |
LED Module 3000 K | LED-0425/930 |
Gasket | 83 001 179 |
BEGA Gantenbrink-Leuchten KG