BEGA 23256.1 Indoor Wall Luminaire Instruction Manual

June 12, 2024
BEGA

BEGA 23256.1 Indoor Wall Luminaire

Product Information

  • Product Description: Mundgeblasenes Opalglas
  • Insulating housing with cable entry for Earth conductor connection
  • LED power supply unit 220-240 V x 0/50-60 Hz DC 176-280 V
  • Safety class I
  • Protection class IP 44 (protected against granular foreign bodies 1 mm and splash water)
  • Impact strength IK02 (protection against mechanical)
  • Weight: 2.2 kg
  • Energy efficiency class(es): D

Product Usage Instructions

  1. The installation and operation of this luminaire are subject to national safety regulations.
  2. Installation and commissioning should only be carried out by a qualified electrician.
  3. Avoid improper use or installation as it may cause damage. The manufacturer accepts no liability for such damage.
  4. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
  5. The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. For additional protection against transients, etc., separate overvoltage protection components are recommended.
  6. For mounting and dismantling, maintain a minimum distance of 350 mm between the removable cap and the wall.

Note: Please refer to the complete user manual for detailed instructions and safety guidelines. The above instructions are a summary and may not cover all aspects of product usage.

Instructions for use

Application
Wall luminaire · indoor luminaire made of hand-blown opal glass and metal housing, for all lighting tasks in interior applications. They are ideal for places where a soft and uniform lighting distribution is required. Luminaire with a high protection class.

Product description

  • Luminaire made of Aluminium, finish Colour white
  • Hand-blown opal glass 2 elongated fixing holes
  • Width 6 mm · 460 mm spacing
  • Insulating housing with cable entry for
  • mains supply cable up to ø 10,5 mm, max. 3 x 1,5@
  • Connection terminal 2.5@
  • Earth conductor connection
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DC 176-280 V
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect temperature-sensitive components
  • Safety class I
  • Protection class IP 44
  • Protected against granular foreign bodies
  • ≥ 1 mm and splash water
  • Impact strength IK02
  • Protection against mechanical impacts < 0.2 joule
  • – Safety mark
  • – Conformity mark
  • Weight: 2.2 kg
  • This product contains light sources of energy efficiency class(es) DBEGA-23256.1-Indoor-Wall-Luminaire-fig-3

Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage
  • Luminaire connected wattage
  • Rated temperature
  • Ambient temperature

23 256.1 K3

  • Module designation
  • Colour temperature
  • Colour rendering index
  • Module luminous flux
  • Luminaire luminous flux
  • Luminaire luminous efficiency

preliminary data

Insulation housing

Installation

For mounting and dismantling please keep a minimum distance of 350 mm between the removable cap and the wall. LEDs are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.

Open luminaire:
Loosen knob, remove cap and glass. Drill mounting holes into the mounting surface – spacing 460 mm. For the mains supply connecting open the insulation housing – pull open – strip mains supply cable max. 15 mm and lead it into the insulation housing – see sketch. Make earth conductor connection and electrical connection. Connect both parts of the insulation housing until they audibly engage. The outer coating of the cable has to be fully enclosed by the compression nipple. Fix luminaire with enclosed or any other suitable fixing material onto the mounting surface. Place glass into luminaire housing, close luminaire with the cap and screw in knob into the cap.

Replacement of the LED module
The designation of the LED module is noted on a label in the luminaire. The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools. Disconnect the system. Loosen lateral knob, remove cap and take out glass. Please follow the installation instructions for the LED module. Defective glass must be replaced. Insert glass into luminaire housing, close luminaire with the cap and screw in knob into the cap.

Spares

  • Spare glass: 11 002 525 .1R G
  • LED power supply unit: DEV-0136/350
  • LED module 3000 K: LED-0425/930
  • Gasket: 83 001 179

BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com
www.bega.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>