BEGA 50125.1 LED Wall Luminaire Instruction Manual
- June 12, 2024
- BEGA
Table of Contents
BEGA 50125.1 LED Wall Luminaire Instruction Manual
Dimension
Instructions for use
Application
Free-radiating wall wall luminaire · indoor luminaire made of hand-blown opal
glass, satin matt and metal housing.
The character of the three-ply opal glass creates a smooth and uniform light
distribution in the room.
Product description
Metal housing, finish Colour white
Hand-blown opal glass, satin matt
Mounting plate with 2 fixing
holes ø 6mm · 70mm spacing
1 cable entry for mains supply cable
up to ø 10.5 mm max. 3 x 1.5@
Connection terminal 2.5@
Earth conductor connection
LED-Module for mains voltage
220-230 V y 50/60 Hz
BEGA Thermal Switch®
Temporary thermal shutdown to protect
temperature-sensitive components
Safety class I
– Safety mark
– Conformity mark
Weight: 0.85 kg
This product contains light sources of energy efficiency class(es) G
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend
separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Luminaire connected wattage 7.4 W
Rated temperature ta=25 °C
Ambient temperature ta max=30 °C
50 125.1K3
Module designation LED-0662/930
Colour temperature 3000 K
Colour rendering index Ra > 90
Module luminous flux 660 lm
Luminaire luminous flux 437 lm
Luminaire luminous efficiency 59,1 lm/W
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
Take off glass from luminaire base.
Lead the mains supply cable through the cable entry of the luminaire base.
Fix luminaire base with enclosed or any other suitable fixing material onto
the mounting surface.
Be sure to use the gasket rings supplied.
Notice position of use “arrow down” of the luminaire base.
Establish earth conductor connection and make the electrical connection to the
terminals.
Insert glass into luminaire base.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by a
qualified electrician or a comparably qualified person using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Defective glass must be replaced.
Close the luminaire.
Spares
Spare glass 11 003 202 .0RG
LED module 3000 K LED-0662/930
BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden · info@bega.com · www.bega.com