BEGA 50265.1 LED Wall Luminaire Instruction Manual

June 12, 2024
BEGA

50265.1 LED Wall Luminaire
Instruction Manual
Technical amendments reserved

50265.1 LED Wall Luminaire

Wall luminaire for indoor use  BEGA 50265.1 LED Wall Luminaire -
overview

Instructions for use

Application
Shielded wall luminaire · indoor luminaire made of hand-blown opal glass, satin matt with metal shield, for many lighting tasks.
The light emits upwards and downwards.

Product description

Metal housing, finish colour white
Hand-blown opal glass, satin matt
Metal shield, white
2 elongated fixing holes
Width 4.5 mm · 285 mm spacing
1 cable entry for through-wiring for mains cable
Connecting terminals 2.5@
Earth conductor connection
LED-Module for mains voltage
220-230 V y 50/60 Hz
BEGA Thermal Switch®
Temporary thermal shutdown to protect temperature-sensitive components
Safety class I
– Safety mark
**** – Conformity mark
Weight: 1.8 kg
This product contains light sources of energy efficiency class(es) F

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp

Luminaire connected wattage 20 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 30 °C

50 265.1 K3

Module designation 2x LED-0607/930
Colour temperature 3000 K
Colour rendering index Ra > 90
Module luminous flux 1880 lm
Luminaire luminous flux 1189 lm
Luminaire luminous efficiency 59,5 lm / W

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
Lead the mains supply cable through the cable entry of the luminaire base.
Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface.
Be sure to use the gasket rings supplied.
Establish earth conductor connection and make the electrical connection to the terminals.
Advice:
Expansion of glass and metal is different.
Glass must be allowed to expand.
Place glass into the luminaire base and fix set screws handtight.
After tightening the set screws loosen them for half a turn to allow the glass to move.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.
Replacement of the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Defective glass must be replaced.
Close the luminaire.
Spares

Spare glass 11 003 224 .0M RG
LED module 3000 K LED-0607/930

BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com