Wall luminaire for indoor use
Instructions for use
Application
Shielded wall luminaire · indoor luminaire made of hand-blown opal glass,
satin matt with metal shield, for many lighting tasks.
The light emits upwards and downwards.
Product description
Metal housing, finish colour white
Hand-blown opal glass, satin matt
Metal shield, white
2 elongated fixing holes
Width 4.5 mm · 285 mm spacing
1 cable entry for through-wiring for mains cable
Connecting terminals 2.5@
Earth conductor connection
LED-Module for mains voltage
220-230 V y 50/60 Hz
BEGA Thermal Switch®
Temporary thermal shutdown to protect temperature-sensitive components
Safety class I
– Safety mark
**** – Conformity mark
Weight: 1.8 kg
This product contains light sources of energy efficiency class(es) F
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Luminaire connected wattage | 20 W |
---|---|
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 30 °C |
50 265.1 K3
Module designation | 2x LED-0607/930 |
---|---|
Colour temperature | 3000 K |
Colour rendering index | Ra > 90 |
Module luminous flux | 1880 lm |
Luminaire luminous flux | 1189 lm |
Luminaire luminous efficiency | 59,5 lm / W |
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
Lead the mains supply cable through the cable entry of the luminaire base.
Fix luminaire base with enclosed or any other suitable fixing material onto
the mounting surface.
Be sure to use the gasket rings supplied.
Establish earth conductor connection and make the electrical connection to the
terminals.
Advice:
Expansion of glass and metal is different.
Glass must be allowed to expand.
Place glass into the luminaire base and fix set screws handtight.
After tightening the set screws loosen them for half a turn to allow the glass
to move.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacement of the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Defective glass must be replaced.
Close the luminaire.
Spares
Spare glass | 11 003 224 .0M RG |
---|---|
LED module 3000 K | LED-0607/930 |