Product Information

Product Name Wandleuchte Wall luminaire Applique
Model Numbers 31 054, 70 310, 25, 234, 135
Instructions for Use Upwardly shielded cast aluminium wall luminaire.

Luminaire with
hand-blown, three-ply opal glass for a wide range of lighting
applications.
Safety| The installation and operation of this luminaire are subject to
national safety regulations. Installation and commissioning may
only be carried out by a qualified electrician. The manufacturer
accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the
luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Overvoltage Protection| The electronic components installed in the luminaire are
protected against overvoltage in accordance with DIN EN 61547. To
achieve an additional protection against e.g. transients, etc., we
recommend separate overvoltage protection components. You can find
them on our website at www.bega.com.
Lamp| | Module connected wattage| 13.8 W
---|---
Luminaire connected wattage| 16.3 W
Rated temperature| 25 °C
Ambient temperature| 45 °C
Module| | Module designation| LED-1422/830
---|---
Colour temperature| 3000 K
Colour rendering index (CRI)| CRI > 80
Module luminous flux| 2585 lm
Luminaire luminous flux| 1309 lm
Luminaire luminous efficiency| 80.3 lm / W
Spares|

  • LED power supply unit
  • LED module 3000 K
  • Spare glass
  • Gasket housing

Product Usage Instructions

  1. Ensure that the luminaire is installed and operated in compliance with national safety regulations.
  2. Installation and commissioning should only be carried out by a qualified electrician.
  3. Do not make any modifications to the luminaire without proper authorization, as it may void the warranty and result in damage or injury.
  4. For additional protection against overvoltage and transients, consider using separate overvoltage protection components available on our website at www.bega.com.
  5. When replacing the lamp module, use the LED-1422/830 module with a colour temperature of 3000 K and a colour rendering index (CRI) greater than 80.
  6. The module luminous flux is 2585 lm, and the luminaire luminous flux is 1309 lm with a luminous efficiency of 80.3 lm / W.
  7. Ensure that the ambient temperature does not exceed 45 °C, and the rated temperature of the luminaire is 25 °C.
  8. If you require spare parts, you can order the LED power supply unit, LED module 3000 K, spare glass, and gasket housing from us.

DIMENSIONS

BEGA-31054-Wall-Luminaire-FIG-1

Instructions for use

Application

  • Upwardly shielded cast aluminium wall luminaire.
  • Luminaire with hand-blown, three-ply opal glass for a wide range of lighting applications.

Product Description

  • Luminaire made of aluminium alloy, aluminium and stainless steel
  • BEGA Unidure® coating technology
  • Colour graphite or bronze
  • Opal glass
  • Silicone gasket
  • 2 mounting holes ø 5.5 mm
  • Distance apart 234 mm
  • 2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm, max. 5 G 1.5@
  • Connecting terminal 2.5@ with plug connection
  • Earth conductor connection
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DALI-controllable
  • Number of DALI addresses: 1
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire

Safety class I

  • Protection class IP 65
  • Dust-tight and protection against water jets Impact strength IK04
  • Protection against mechanical
  • impacts < 0.5 joule
  • – Safety mark
  •  – Conformity mark
  • Weight: 3.4 kg
  • This product contains light sources of energy efficiency class(es) C

Safety

  • The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 13.8 W
  • Luminaire connected wattage 16.3 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 45 °C

31 054 K3

  • Module designation LED-1422/830
  • Colour temperature 3000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 2585 lm
  • Luminaire luminous flux 1309 lm
  • Luminaire luminous efficiency 80,3 lm / W

Installation

  • Lead the mains supply cable through the cable entry of the luminaire base.
  • Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface.
  • Make the earth conductor connection and the electrical connection.
  • For digital control please use the connecting terminal DA, DA.
  • In case this terminal is not used the luminaire will be operated at full light output.
  • In order to guarantee the maximum service life of the electrical components, the enclosed desiccant pouch must be placed in the luminaire.
  • Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label immediately before finally closing the luminaire.
  • Push plug into coupler as far as it will go. Make sure that gasket is positioned correctly. Place the opal glass with LED unit onto the luminaire base in such a way that both yellow arrow markers align to each other and screw the glass clockwise into the base up to the stop.

Cleaning · Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
  • Do not use high pressure cleaners.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced.
  • Close the luminaire.

Spares

  • LED power supply unit DEV-0475/500
  • LED module 3000 K LED-1422/830
  • Spare glass 75 004 032
  • Gasket housing 83 001 574

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com