WARNING! To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
WARNING! Unit must be grounded. Do not use with an extension cord. Connect only to an outlet provided with a ground fault interrupting device.
WARNING! Never operate a unit with a damaged power cord, as this may lead to electrical or fire hazards. If power cord is damaged, it must be replaced by a cord of the same type and amperage rating.
WARNING! Do not touch grills when unit is operating.
WARNING! Do not allow children to play with or around the unit. Be sure the unit is inaccessible to children when not attended.
WARNING! Always operate the unit on a stable, level surface so it cannot fall and cause injur
WARNING! Do not operate any fan with a damaged cord or plug. Discard fan or return to an authorized service facility for examination and/or repair.
WARNING! Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area to avoid creating a trip hazard.
NOTICE: Keep motor dry. For indoor use only.
NOTICE: Unplug when not in use or when moving unit.
NOTICE: Do not alter or modify your Velo in any way. Use only replacement parts authorized by Legend Brands, Inc. Modifications or use of unapproved parts could create a hazard and will void your warranty. Contact your authorized Dri-Eaz distributor for assistance.

BEFORE YOU BEGIN

Warranty registration

Please visit warranty.legendbrandsrestoration.com to register your purchase. If you determine service is

Fig. A: Parts Identification

Fig. B: Operating Positions

Horizontal (for horizontal surfaces)c


With stand for stairwells and wall drying (Pro only)

|

Left edge (for wall drying)

Right edge (for wall drying)|

Vertical (for walls and ceilings)

required, have your equipment model, serial number and original proof of purchase available and call your distributor for assistance with obtaining a return material    authorization (RMA).

OPERATING INSTRUCTIONS

Note that the Velo can be placed in a variety of positions for drying and air circulation. See Fig. B for details.

  1. Unwrap the cord and plug the unit into a standard 115V GFCI-protected outlet. CAUTION: Be sure switch is in the off position before connecting unit to power outlet.
  2. Direct the Velo outlet toward the surface to be dried. TIP: On the Velo Pro (F505), the airflow may be adjusted by pressing the Up or Down arrow on the speed control (Fig. D). A digital readout shows the approximate amp draw. Use this value to maximize the number of Velos you can place on a single circuit.
  3. When surface is dry to the touch, switch the unit off and reposition the unit in the next area to be dried.
  4. When finished, unplug the unit and re-wrap the cord in the cord wrap.

For additional instructions about the use of airmovers for restorative drying, see Tech Tips under Resources on www.LegendBrandsRestoration.com.

Electrical safety devices

Circuit breaker: If the circuit breaker detects overload or short circuit conditions, the breaker will automatically shut off the electrical supply. If this occurs, check the power cable carefully for any damage and ensure it is plugged into a properly grounded outlet. Press the Circuit Breaker Reset Switch (Fig. A) to reestablish the electrical supply. Ground Fault Circuit Interrupter: If the GFCI device detects a ground fault, it will automatically shut off the electrical supply. If this should occur, check the power cable carefully for damage and ensure it is plugged into a properly grounded outlet. Press the GFCI reset button (Fig. A) to reestablish the electrical supply.

TRANSPORT AND STORAGE

Always use the handle to load or carry the unit.
Wrap cord in either direction under front Cord Wrap tab and rear bottom edge (Fig. A). Pull cord snug and secure with plug clip.
Units may be stacked for transport and storage.
When transporting in a vehicle, secure the unit(s) carefully to prevent sliding and damage to the unit and/or injury to vehicle occupants.
Keep unit dry. Do not expose the unit to rain or snow.

MAINTENANCE

WARNING: Unplug unit before performing any maintenance.
Before each use
Inspect the power cord. If cord is damaged, do not use. Always grasp the plug (not the cord) to unplug.
As needed
The exterior may be cleaned with a mild solution of detergent. Ensure housing is completely dry before use. To clean interior, see Fig. C for instructions.

Fig. C: Disassembly

Fig. D: Pro model:

Variable speed control with amp and total unit hours display

FOR SERVICE CALL YOUR LOCAL DISTRIBUTOR or the Legend Brands Service Department at800-932-3030.

Be sure to visit warranty.legendbrandsrestoration.com to register your purchase. Your registration will help us provide you with updated product information as needed.

WARNING: This product and other substances that may become airborne from its use contain chemicals, including lead, known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, go to P65Warnings.ca.gov

SPECIFICATIONS

Model Velo (F504) Velo Pro (F505)
Weight 18.6 lbs. 8.4 kg
Dimensions (D × W × H) 24 × 18 × 9 in.

61 × 45.7 × 22.9 cm

| 24 × 18 × 9 in.

61 × 45.7 × 22.9 cm

Amp draw| 1.9 amps (115V)| 1.2–1.9 amps (115V)
Velos per 15 amp circuit| Up to 6| Up to 10
Power| 185W| 185W
Air movement| 885 CFM | 1504 CMH| 500–885 CFM
850–1504 CMH
Static pressure| 1.65 in. (H2O)| 1.65 in. (H2O)
Sound level (avg.)| 69 dB| 69 dB
Control| On/Off switch| On/Off switch with variable speed
Cord length| 18 ft. | 5.5 m| 18 ft. | 5.5 m
Fan| 6 blades| 6 blades
Construction| Injection molded housing; steel wire inlet and outlet grills.| Injection molded housing; steel wire inlet and outlet grills.
Safety| ETL tested to UL and CSA standards| ETL tested to UL and CSA standards
Specifications are subject to change without notice. Some values may be approximate.

Documents / Resources

| DRIEAZ Velo/Velo Pro Low Profile Airmover [pdf] Owner's Manual
Velo, Velo Pro, Low Profile Airmover, Velo Velo Pro Low Profile Airmover, Velo Low Profile Airmover, Velo Pro Low Profile Airmover
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals