Schneider SQR141U1BKW Energy Monitoring Rocker Switch Instruction Manual

June 6, 2024
Schneider

Schneider-SQR141U1BKW-Energy-Monitoring-Rocker-Switch-
LOGO

Schneider SQR141U1BKW Energy Monitoring Rocker Switch

Features

  •  Manual and Remote ON/OFF control of any connected lighting and another electrical load
  •  Can be used for single-pole or 3-Way (Multi-location) with rocker switch
  •  You can Turn your devices on or off at any time or anywhere have Internet using the free SE Wiser App on your smartphone
  •  Wi-Fi® is a registered trademark of Wi-Fi Alliance R

Specifications / Especificaciones / Caractéristiques

**| SQR141U1W
Voltage / Tensión / Tension| 120 Vac, 60 Hz / 120 Vca, 60 Hz / 120 V CA, 60 Hz
Incandescent lights / Luces incandescentes / Voyants à incandescence| 1000 W
LED lights / Luces LED / Voyants DEL| 5 A
Standard Ballast / Balasto estándar / Ballast standard| 1200 Va / 1200 Va / 1 200 VA
Resistive load / Carga resistiva / Charge résistive| 1800 W (15 A)
Motor / Motor / Moteur| 1/2 Hp
Operating Temperature / Temperatura de operación / Température de fonctionnement| 32–104°F (0–40°C) / De 32 ºF a 104 ºF (de 0 ºC a 40 ºC) / 32 à 104 °F (0 à 40 °C)
Supply Connection / Conexión de alimentación / Raccordement à l’alimentation| 14 AWG 1
Wireless Type / Tipo inalámbrico / Type sans fil| Wi-Fi®, IEEE 802.11b/g/n
Wireless Frequency / Frecuencia inalámbrica /| 2.4 GHz

PRECAUTIONS

Schneider-SQR141U1BKW-Energy-Monitoring-Rocker-Switch-
FIG

  WARNING / ADVERTENCIA / AVERTISSEMENT

HAZARD OF HEAT AND FIRE DAMAGE

Read all instructions before installation. The manufacturer will not be held responsible for product damage resulting from not following the instructions.

•  Wet hands are strictly prohibited.

•  Work strictly according to the rated load.

•  Do not continue working after self-disassembly of any nature and damage of external forces.

Failure to follow these instructions can result in death, serious injury, or equipment damage.

| PELIGRO DE DAÑO POR CALENTAMIENTO E INCENDIO

Lea todas las instrucciones antes de la instalación. El fabricante no será responsable por los daños causados al producto por no seguir las instrucciones.

•  Está estrictamente prohibido tener las manos mojadas.

•  Trabajar estrictamente de acuerdo con la carga nominal.

•  No siga trabajando si se produce un desmontaje de cualquier naturaleza, o daño por fuerzas externas.


El incumplimiento de estas instrucciones puede causar la muerte, lesiones serias o daño al equipo.

| RISQUE DE DOMMAGE CAUSÉ PAR LA CHALEUR ET LE FEU

Lisez toutes les instructions avant l’installation. Le fabricant ne pourra pas être tenu responsable des dégâts causés au produit qui peuvent survenir si ces instructions ne sont pas respectées.

•  Il est strictement interdit de l’utiliser avec les mains mouillées.

•  Travaillez en respectant strictement la charge nominale !

•  Arrêtez de travailler après une désintégration accidentelle de quelque nature que ce soit et des dommages causés par des forces extérieures.

Si ces directives ne sont pas respectées, cela peut entraîner la mort, des blessures graves ou des dommages matériels.

Installation

1. Turn the power OFF at circuit breaker or fuse and test that power is off, using a properly rated voltage sensing device, before wiring.
2. Wire the device according to the wiring diagram.
3. Check that all connections are tight and no bare wires exposed.
4. Install the receptacle into the standard outlet box using the screws provided.

Single-Pole Wiring DiagramSchneider-SQR141U1BKW-Energy-Monitoring-Rocker-
Switch-FIG-1

WAY WIRING DIAGRAM

Schneider-SQR141U1BKW-Energy-Monitoring-Rocker-
Switch-FIG-2

Wall Plates

Schneider-SQR141U1BKW-Energy-Monitoring-Rocker-Switch-
FIG-3

**Operation

**

Local control:
NOTE: After a power loss the switch returns to the off state.

Local Control
Wireless Range Conditions
The wireless range is the effective distance of remote control and it will be impacted by the following conditions:

  •  Each wall or obstacle (e.g., refrigerator, TV, etc.) between the remote or device and the destination device will reduce the wireless range.
  •  Brick, tile, or concrete walls block more of the wireless signal than walls made of wooden studs and plasterboard (drywall).
  •  The angle of direction between the remote or device and the destination device will also impact the wireless range; normally, placing the devices face-to-face will get the best wireless range
  •  Wall-mounted devices installed in metal junction boxes may suffer a significant loss of range since the metal box blocks a large part of the wireless signal.

LED Indication

Indication / State / Description /
**** AP The LED indicator shall start single blinking.

| Connected| The LED indicator will be turned to solid on once the cloud connectivity is established. The on state shall last for up to 1 minute.


| Offline| Once the device is offline, it shall enter a double blinking pattern for 3 minutes. After, the indicator shall track load status.


| Operating| The LED indicator shall track the load on/off status. By default, when load is on, the LED should be on, and vice versa. Notice the tracking state could be reversed if it is configured so.

Restoring Procedure

L0 reset: Wi-Fi function reboot. Long press (T > 5s) reset button.
L1 reset: Leave network; Re-enter AP mode. Long press (T > 10s) reset button.
L2 reset: Leave network and clear all configurations. Long press (T > 20s)

reset button.

FCC Compliance Statement

  • Federal Communication Commission Interference Statement
  • The equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment uses, generates, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communication. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
    •  Reorient or relocate the receiving antenna.
    •  Increase the separation between the equipment and receiver.
    •  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
    •  Consult the dealer or an experienced radio/TV technician for help.

FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body.
RF Exposure: A distance of 20 cm shall be maintained between the antenna and users, and the transmitter module may not be co-located with any other transmitter or antenna.

Non-modification statement
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.

FCC Supplier’s Declaration of Conformity
Product Name: Wi-Fi® SWITCH, SINGLE POLE
Model number: SQR141U1WHW, SQR141U1LAW, SQR141U1BKW
Suppliers Name: Schneider Electric
Suppliers Address (USA): 800 Federal Street Andover, MA 01810 USA
Suppliers Website: www.se.com/us

FCC Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Schneider User Manuals