Product Information

Product Name| Decken- und Wandleuchte Ceiling and wall luminaire Plafonnier
et applique
---|---
Model Number| 24 171
IP Rating| IP 65
Description| Unshielded ceiling and wall luminaire with high protection
class. A luminaire made of aluminium alloy and crystal glass.

Dimension

BEGA-24-171-Ceiling-and-Wall-Luminaire-FIG-1

Instructions for use

Application
Unshielded ceiling and wall luminaire with high protection class. A luminaire made of aluminium alloy and crystal glass.
Product description
Luminaire made of aluminum alloy,aluminum and stainless steel began Unidure® coating technologyCrystal glass with optical structureSilicone gasket2 mounting holes ø 4.5 distance apart 325 mm2 screw cable glands with strain relieffor through-wiring power connecting cableø 7–12 mm1 screw cable gland closed at the factory witha dummy plug connection terminal 2.5@Earth conductor connection power supply unit 220-240 V x 0/50-60 Hz DC 170-280 VDALI- controllable Basic insulation is provided between the mainland control cables BEGA Thermal Switch®Temporary thermal shutdown to protect temperature- sensitive components safety class Ip Ballproof according to DIN VDE 0710part 13Protection class IP 65Dust-tight and protection against water jetsImpact strength IK10Protection against mechanical impacts < 20 jouler – Safety markc – Conformity mark Weight: 4.6 kg This product contains light sources of energy efficiency classes C, D

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.The manufacturer accepts no liability for damage caused by improper use or installation.If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.To achieve additional protection against. g. transients, etc. we recommend separate overvoltage protection components.You can find them on our website at www.bega.com.

  • Lamp
    • Module connected wattage 23.9 W
    • Luminaire connected wattage 27.2 W
    • Rated temperature ta = 25 °C
    • Ambient temperature ta max = 35 °C
  • 24 171 K3
    • Module designation LED-0993/830
    • Colour temperature 3000 K
    • Colour rendering index CRI > 80
    • Module luminous flux 3975 lm
    • Luminaire luminous flux 2131 lm
    • Luminaire luminous efficiency 78,3 lm / W
  • 24 171 K4
    • Module designation LED-0993/840
    • Colour temperature 4000 K
    • Colour rendering index CRI > 80
    • Module luminous flux 4180 lm
    • Luminaire luminous flux 2241 lm
    • Luminaire luminous efficiency 82,4 lm / W

Installation
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping. Undo hexagon socket head screws (wrench size 3 mm) through the opening in the luminaire housing up to the stop and lift luminaire top. Disconnect the earth conductor connection from the plug connection. Disconnect the plug-connection of the LED connecting cable. Lead the mains supply cable through the screw cable gland into the luminaire back housing. The installed black gasket insert is intended for cables ø < 10 mm. For cables ø 10-12 mm the enclosed grey gasket insert must be used. In case of through-wiring replace the factory- installed dummy plug with the enclosed corresponding gasket insert. At the same time, use the enclosed synthetic cone-thrust collar between the gasket insert and thrust screw (wrench size 22 mm) (see sketch).BEGA-24-171
-Ceiling-and-Wall-Luminaire-FIG-2
Tighten the screw cable gland. Fix the luminaire base with enclosed or any other suitable fixing material onto the mounting surface. Make the earth conductor connection and the electrical connection. For digital control please use the connecting terminal DA, DA. In case this terminal is not used the luminaire will be operated at full light output.
In order to guarantee the maximum service life of the electrical components, the enclosed desiccant pouch must be placed in the luminaire. Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label immediately before finally closing the luminaire. Make earth conductor connection between the luminaire top and the luminaire base. Push the plug into the coupler as far as it will go.BEGA-24-171
-Ceiling-and-Wall-Luminaire-FIG-3
Make sure that gasket is positioned correctly. Tighten grub screws evenly.

Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits. Do not use high-pressure cleaners.

Replacing the LED module

The designation of the LED module is noted on a label in the luminaire. The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools. Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module. Inspect and, if necessary, replace the luminaire gaskets. Defective glass must be replaced. Close the luminaire.

  • Spares
    • Spare glass 11 003 519
    • LED power supply unit DEV-0365/700
    • LED module 3000 K LED-0993/830
    • LED module 4000 K LED-0993/840
    • Gasket glass 83 001 927
    • Gasket wall plate 83 002 166 B1