MEAN WELL SD-200 Series 200W Single Output DC DC Converter Owner’s Manual
- June 12, 2024
- MEAN WELL
Table of Contents
200W Single Output DC-DC Converter
SD – 200 series
Features
- 2:1 wide input range
- Protections: Short circuit / Overload / Over voltage / Over temperature
- 1500VAC I/O isolation
- Cooling by free air convection
- 100% full load burn-in test
- 24V and 48V input voltage design refer to LVD
- 2 years warranty
https://www.meanwell.com/Upload/PDF/DC- DC_EN.pdf
■ GTIN CODE
MW Search• https://www.meanwell.com/serviceGTIN.aspx
(for SD-200C-5/12/24 type only)
SPECIFICATION
MODEL | SD-200B | SD-200C |
---|---|---|
OUTPUT | DC VOLTAGE | 5V |
RATED CURRENT | 34A | 16.7A |
CURRENT RANGE | 0 ~ 34A | 0 ~ 16.7A |
16.7A | 0 ~ 8.4A | 0 ~ 4.2A |
RATED POWER | 170W | 200.4W |
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 120mVp-p |
200mVp-p | 100mVp-p | 120mVp-p |
VOLTAGE ADJ. RANGE | 4.5 ~ 5.5VDC | 11 ~ 16VDC |
4.5 ~ 5.5VDC | 11 ~ 16VDC | 23 ~ 30VDC |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% |
±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% |
LOAD REGULATION | ±1.0% | ±1.0% |
SETUP, RISE TIME | 300ms, 50ms at full load | |
INPUT | VOLTAGE RANGE | B:19 ~ 36VDC C:36 ~ 72VDC |
D:72 ~144VDC
EFFICIENCY (Typ.)| 79%| 82%| 85%| 86%| 81%| 84%| 86%| 86%
DC CURRENT (Typ.)| 10.8A/24V| 10.6A/24V| 10.4A/24V| 10.4A/24V| 5.4A/48V|
5.2A/48V| 6.7A/48V| 5A/48V
INRUSH CURRENT (Typ.)| C:45A/48VDC D:45A/96VDC
PROTECTION| OVERLOAD| 105 ~ 135% rated output power
Protection type : Shut down o/p voltage, re-power on to recover
OVER VOLTAGE| 5.75 ~ 6.75V| 16.8 ~ 20V| 31.5 ~ 37.5V| 53 ~ 65V| 5.75 ~
6.75V| 16.8 ~ 20V| 31.5 ~ 37.5V| 53 ~ 65V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after
temperature goes down
ENVIRONMENT| WORKING TEMP.| -20 ~ +60℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & **EMC (Note 4)| SAFETY STANDARDS| UL62368-1approved
(for SD-200C-5/12/24 type only), EAC TP TC 004 approved, design refer to
AS/NZS 62368.1
WITHSTAND VOLTAGE| I/P-O/P:1.5KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, EAC TP TC
020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,6,8, light industry
level, EAC TP TC 020
OTHERS| MTBF| 1919.7K hrs min. Telcordia SR-332 (Bellcore) ;
280.6K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 21511550mm (LWH)
PACKING| 1.1Kg; 12pcs/14.4Kg/0.9CUFT
NOTE*| 1. All parameters NOT specially mentioned are measured at
24,48,96VDC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted
pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load
regulation.
4. The power supply is considered a component which will be installed into a
final equipment. All the EMC tests are been executed by mounting the unit on a
360mm360mm metal plate with 1mm of thickness. The final equipment must be re-
confirmed that it still meets EMC directives. For guidance on how to perform
these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. The ambient temperature derating of 3.5℃/1000m with fanless models and of
5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to
https://www.meanwell.com/serviceDisclaimer.aspx
200W Single Output DC-DC Converter
SD – 200 series
Features
- 2:1 wide input range
- Protections: Short circuit / Overload / Over voltage / Over temperature
- 1500VAC I/O isolation
- Cooling by free air convection
- 100% full load burn-in test
- 24V and 48V input voltage design refer to LVD
- 2 years warranty
SPECIFICATION
MODEL | SD-200D |
---|---|
OUTPUT | DC VOLTAGE |
RATED CURRENT | 40A |
CURRENT RANGE | 0 ~ 40A |
RATED POWER | 200W |
RIPPLE & NOISE (max.) Note.2 | 100mVp-p |
VOLTAGE ADJ. RANGE | 4.5 ~ 5.5VDC |
VOLTAGE TOLERANCE Note.3 | ±2.0% |
LINE REGULATION | ±0.5% |
LOAD REGULATION | ±1.0% |
SETUP, RISE TIME | 300ms, 50ms at full load |
INPUT | VOLTAGE RANGE |
D:72 ~144VDC
EFFICIENCY (Typ.)| 82%| 82%| 84%| 90%
DC CURRENT (Typ.)| 3.5A/96V| 3.5A/96V| 3.5A/96V| 3.5A/96V
INRUSH CURRENT (Typ.)| C:45A/48VDC D:45A/96VDC
PROTECTION| OVERLOAD| 105 ~ 135% rated output power
Protection type : Shut down o/p voltage, re-power on to recover
OVER VOLTAGE| 5.75 ~ 6.75V| 16.8 ~ 20V| 31.5 ~ 37.5V| 53 ~ 65V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after
temperature goes down
ENVIRONMENT
| WORKING TEMP.| -20 ~ +60℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & **EMC (Note 4)| SAFETY STANDARDS| IEC/BS EN/EN
62368-1, EAC TP TC 004 approved, design refer to AS/NZS 62368.1
WITHSTAND VOLTAGE| I/P-O/P:1.5KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION| Compliance to BS EN/EN55022 (CISPR22) Class B, EAC TP TC
020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,6,8, light industry
level, EAC TP TC 020
OTHERS| MTBF| 1919.7K hrs min. Telcordia SR-332 (Bellcore) ;
280.6K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 21511550mm (LWH)
PACKING| 1.1Kg; 12pcs/14.4Kg/0.9CUFT
NOTE*| 1. All parameters NOT specially mentioned are measured at
24,48,96VDC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted
pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load
regulation.
4. The power supply is considered a component which will be installed into a
final equipment. All the EMC tests are been executed by mounting the unit on a
360mm360mm metal plate with 1mm of thickness. The final equipment must be re-
confirmed that it still meets EMC directives. For guidance on how to perform
these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. The ambient temperature derating of 3.5℃/1000m with fanless models and of
5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer: For detailed information, please refer to
https://www.meanwell.com/serviceDisclaimer.aspx
File Name:SD-200-SPEC 2022-02-28
Documents / Resources
| MEAN
WELL SD-200 Series 200W Single Output DC DC
Converter
[pdf] Owner's Manual
SD-200 Series 200W Single Output DC DC Converter, SD-200 Series, 200W Single
Output DC DC Converter, Single Output DC DC Converter, Output DC DC Converter,
DC Converter, Converter
---|---
| MEAN
WELL SD-200 Series 200W Single Output DC-DC
Converter
[pdf] Owner's Manual
SD-200 Series 200W Single Output DC-DC Converter, SD-200 Series, 200W Single
Output DC-DC Converter, Single Output DC-DC Converter, Output DC-DC Converter,
DC-DC Converter, DC Converter, Converter
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>