Product Information
Safety| The installation and operation of this luminaire are subject to
national safety regulations. Installation and commissioning may
only be carried out by a qualified electrician. The manufacturer
accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the
luminaire, the person responsible for these modifications shall be
considered the manufacturer.
---|---
Overvoltage Protection| The electronic components installed in the luminaire
are
protected against overvoltage in accordance with DIN EN 61547. To
achieve an additional protection against e.g. transients, etc., we
recommend separate overvoltage protection components. You can find
them on our website at www.bega.com.
Lamp Module Connected Wattage| 24.1 W
Luminaire Connected Wattage| 28.5 W
Rated Temperature| Ambient temperature maximum: 25°C
Module Designation| LED-0800/930
Colour Temperature| 3000 K
Colour Rendering Index| CRI > 90
Module Luminous Flux| 3350 lm
Luminaire Luminous Flux| 1446 lm
Luminaire Luminous Efficiency| 50.7 lm/W
Product Usage Instructions
- The luminaire should only be installed and operated by a qualified electrician in compliance with national safety regulations. Improper use or installation may result in damage for which the manufacturer will not be liable.
- For additional protection against overvoltage, it is recommended to use separate overvoltage protection components available on our website at www.bega.com.
- The connected wattage for the lamp module is 24.1 W, and for the luminaire is 28.5 W.
- The luminaire can operate at a maximum ambient temperature of 25°C.
- The module designation for this luminaire is LED-0800/930, with a colour temperature of 3000 K and a colour rendering index (CRI)greater than 90.
- The module luminous flux is 3350 lm, and the luminous flux of the luminaire is 1446 lm. The luminaire has a luminous efficiency of 50.7 lm/W.
Dimension
Instructions for use
Application
Recessed ceiling luminaire · indoor luminaire with crystal glass for wide beam
light. For installation in suspended ceilings of 10- 50 mm in interior
applications. A remote power supply unit is required to operate this
luminaire. If this luminaire should be integrated into a LCN or Zigbee-
controlled building management system we recommend our BEGA Control light
control system.
Product description
LED recessed luminaire without power supply unitLuminaire made of cast
aluminium, aluminium and stainless steel Crystal glass with thread, partially
frosted Silicone gasket Reflector made of pure anodised aluminium Ceiling
frame ring made of stainless steel Luminaire housing with 2 fixing claws and
guide screws Ceiling aperture ø 160 mm Free space installation depth required
95 mm 0,5 m mains supply cable A05VV-F 2 × 0,5@ with plug 1 connecting cable
with strain relief and plug connector system for BEGA power supply unit,
on/off or DALI Safety class III 3 Protection class IP 65 Dust-tight and
protection against water jets Impact strength IK06Protection against
mechanical impacts < 1 joulec – Conformity markWeight: 1.8 kg This product
contains light sources of energy efficiency class(es) E
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician. The manufacturer accepts no liability for damage
caused by improper use or installation. If subsequent modifications are made
to the luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547. To achieve an additional
protection against e. g. transients, etc. we recommend separate overvoltage
protection components. You can find them on our website at
www.bega.com.
- Lamp
- Module connected wattage 24.1 W
- Luminaire connected wattage 28.5 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 30 °C
- 50 004.2 K3
- Module designation LED-0800/930
- Colour temperature 3000 K
- Colour rendering index CRI > 90
- Module luminous flux 3350 lm
- Luminaire luminous flux 1446 lm
- Luminaire luminous efficiency 50,7 lm / W
Lighting technology
Half beam angle 46°
Installation
l Luminaire housing must not be installed in heat-insulating material.
A separate power supply unit is required to operate the luminaire.
For connection to external LED-power supply unit – accessory 13 193 or 10
530 – the luminaire is equipped with a connector.Note operating instructions
of the LED-power supply units. LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
Installation into concrete ceilings: For the installation of luminaire
and external power supply unit we recommend to use installation housing 10
442.
Installation into inserted ceilings: A recessed opening of ø 160 mm is
necessary to accept the luminaire housing.Free space depth min. 95 mm. The
lateral distance between recessed luminaire and other building parts must be
at least 50 mm.The claws catch the ceiling facing from the back side. Minimum
thickness of the ceiling facing is 10 mm. If the ceiling facing has a
thickness of less than 10 mm or in case of an installation into plasterboard
ceilings, the facing thickness in the region of the claws must be increased
from the back side. Remove glass with reflector from luminaire housing by
turning counter-clockwise. Connect plug part of the luminaire with power
supply unit.
Push external LED power supply unit and luminaire housing into the ceiling
cut-out.
Luminaire housing and external LED power supply unit must not be
covered by any heat insulating materials.
Tighten guide screws. When tightening the screws, the fixing claws must swivel
onto the inside of the suspended ceiling. The luminaire is fixed. When undoing
the guide screws, the fixing claws swivel back and the luminaire can be
removed. Lead enclosed trim ring with gasket over the screw-neck of the glass.
Make sure that gasket is positioned correctly. Insert glass with mounted
reflector and frame ring by turning it clockwise into luminaire housing.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt. Defective
glass must be replaced.
Replacement of the LED module
The designation of the LED module is noted on a label in the luminaire. The
light colour and light output of BEGAreplacement modules correspond to those
of the modules originally fitted. The module can be replaced by qualified
persons using standard tools. Disconnect from main supply. Unscrew glass with
ceiling frame ring from luminaire housing by turning it counterclockwise.
Please follow the installation instructions for the LED module.Check gasket.
Screw in glass with ceiling frame ring by turning it clockwise beyond the
stop. Defective glass must be replaced.
Accessories
Power supply units for LED luminaires 220-240 V · 0/50-60 Hz with strain
relief and plug connector system.
- 13 193 Power supply unit on/off
- 10 530 Power supply unit DALI
The power supply units are only suitable for the operation of one LED luminaire. 10 442 Installation housing For the accessories a separate instructions for use can be provided upon request.
- Spares
- Spare glass 11 003 092 10R G
- LED module 3000 K LED-0800/930
- Trim ring 71 001 573 L1
- Reflector 76 001 336
- Gasket 83 001 576
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com