BEGA 51037.1K3 LED Track Spotlight Instruction Manual
- June 12, 2024
- BEGA
Table of Contents
Technical amendments reserved
Instruction Manual
Track spotlight for indoor use
Instructions for use
Application
Ceiling mounted track spotlight · indoor luminaire for 3-phase Eurostandard-
Plus ® track systems.
The optical system of the washer is swivelmounted and rotatable.
Symmetrical wide beam light distribution.
Optical filters are available as accessories for changing the light
distribution.
BEGA Hybrid Optics® : Highly efficient and low- loss light distribution,
thanks to reflector and optical lens.
Product description
GENIUS Track spotlight with adapter Cast aluminium luminaire housing, finish
Colour velvet white, Polycarbonate track adapter with integrated LED power
supply unit Trim ring · Chrome finish Safety glass, with internal optical
filter Optical silicone lens · BEGA Hybrid Optics® Reflector surface made of
pure aluminium LED power supply unit 220-240 V y 50/60 Hz DALI-controllable
Number of DALI addresses: 1 Basic insulation is provided between the mains and
control cables Safety class II 2 – Conformity mark Weight: 0.65 kg This
product contains light sources of energy efficiency class(es) E
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician. The manufacturer accepts no liability for damage
caused by improper use or installation. f subsequent modifications are made
to the luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components. You can find them on our
website at www.bega.com.
Lamp
Module connected wattage | 12.3 W |
---|---|
Luminaire connected wattage | 14.5 W |
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 55 °C |
51 037.1 K3
Module designation | LED-0986/930 |
---|---|
Colour temperature | 3000 K |
Colour rendering index | CRI > 90 |
Module luminous flux | 1685 lm |
Luminaire luminous flux | 1202 lm |
Luminaire luminous efficiency | 82,9 lm / W |
51 037.1 K4
Module designation | LED-0986/940 |
---|---|
Colour temperature | 4000 K |
Colour rendering index | CRI > 90 |
Module luminous flux | 1710 lm |
Luminaire luminous flux | 1233 lm |
Luminaire luminous efficiency | 85 lm / W |
Light technique
Track spot · surface washer with adjustable optical system.
Optical system 0-340° swivel-mounted and ± 310° infinitely rotatable around
the vertical luminaire axis.
Symmetrical wide beam light distribution.
Half beam angle 28°
The symmetrical light cone can be changed to a flat beam, symmetrically
diffuse or asymmetrical light distribution for special lighting applications
by replacing the optical filter (standard) – accessoires.
For flat beam light distribution: Optical filter 13 287
For symmetrically diffuse light distribution: Optical filter 13 310
For asymmetrical light distribution: Optical filter 13 309
|
---|---
standard| flat beam
|
symmetrically diffuse| asymmetrical
The light cone can be adjusted by ±360° by turning the trim ring.
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
The track spotlight with adapter is ready for operation in 3-phase
EUROSTANDARD-PLUS® track systems.
The mounting is done without tools in the bus bar.
IMPORTANT:
Ensure that the adapter’s two lateral stays are located on the same side as
the matching guide profile of the track before installing the adapter in the
3-phase EUROSTANDARDPLUS® track system.
To select the phase ( 1 2 3 ) the turning knob on the rear side of the adapter
has to be operated accordingly.
Screw enclosed fastening ring (a) with attached reflector into the luminaire
housing by turning it clockwise until it stops, so that it is fixed by
clamping.Clip the enclosed trim ring with glass and internal optical
filter (b) onto the luminaire housing by applying slight pressure.Place
the surface washer adapter flush on the conductor rail in the desired
position.
Push the two fixing levers on the underside of the adapter to the right until
they click into their end position.
Set the desired LED beam direction by turning and tilting the luminaire
housing.
Move the two fixing levers in opposite directions until they disengage to
unlock the adapter.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The replacement can be carried out by
a qualified person using standard tools.
Disconnect the system and open the luminaire.
Uninstall the reflector.
Please follow the installation instructions for the LED module.
Install the reflector. Defective glass must be replaced. Close the luminaire.
Accessories · Optical filters
13 287 Optical filter flat beam
13 310 Optical filter symmetrical, diffuse
13 309 Optical filter asymmetrical
For the accessories a separate instructions for use can be provided upon
request.
Spares
Prismatic film | 15 000 683 |
---|---|
Fastening ring reflector | 20 000 106 B5 |
LED power supply unit | DEV-0437/350i |
LED module 3000 K | LED-0986/930 |
LED module 4000 K | LED-0986/940 |
Reflector unit | 75 004 444 |
Trim ring with glass | 75 004 843 |
BEGA Gantenbrink-Leuchten KG
· Postfach 31 60
· 58689 Menden
· info@bega.com
· www.bega.com
References
Read User Manual Online (PDF format)