Product Information
- The luminaire is subject to national safety regulations and should be installed and commissioned by a qualified electrician.
- The manufacturer does not accept liability for damage caused by improper use or installation.
- The luminaire’s electronic components are protected against overvoltage according to DIN EN 61547.
- Additional overvoltage protection components are recommended for extra protection against transients, etc.
- The connected wattage for the lamp module is 19.2 W, and for the luminaire is 22.6 W.
- The rated temperature range is between 25°C and 45°C.
- The module designation for the luminaire is 50 140.2 K3, and for the lamp module is 2x LED-0783/930.
- The colour temperature is 3000 K, and the colour rendering index (CRI) is greater than 90.
- The module luminous flux is 3150 lm, and the luminaire luminous flux is 1864 lm.
- The luminaire luminous efficiency is 82.5 lm/W.
Product Usage Instructions
Safety:
- Ensure that the installation and operation of the luminaire comply with national safety regulations.
- Only a qualified electrician should perform the installation and commissioning.
- Improper use or installation may result in damage, for which the manufacturer is not liable.
- If modifications are made to the luminaire, the person responsible for these modifications will be considered the manufacturer.
Overvoltage Protection:
- The luminaire’s electronic components are protected against overvoltage according to DIN EN 61547.
- For additional protection against transients, it is recommended to use separate overvoltage protection components available on the manufacturer’s website.
Replacement of LED Module:
- – The designation of the LED module can be found on a label inside the luminaire.
- BEGA replacement modules have the same light colour and output as the original modules.
- Qualified individuals can replace the module using standard tools.
- Before replacing the module, disconnect the system and open the luminaire.
- Follow the installation instructions provided for the LED module.
- If the glass is defective, it should be replaced. – Close the luminaire after completing the replacement.
Note : When mounting the luminaire onto a metallic, electroconductive surface, ensure that the mounting surface is connected conductively to the earth conductor of the luminaire. Maintain a distance of 450 mm above the luminaire when replacing the LED module, mounting, or dismantling the glass.
Wall luminaire for indoor use
DIMENSIONS
Instructions for use
Application
Free-radiating wall luminaire · indoor luminaire made of hand-blown opal
glass, satin matt and metal housing.
The character of the three-ply opal glass creates a smooth and uniform light
distribution in the room.
Product Description
- Glass holder made of matt brushed aluminum Hand-blown opal glass, satin matt
- 2 mounting holes ø 6 mm
- Distance apart 197 mm
- Connection terminal 2.5@
- Earth conductor connection
- Installation surface 545 x 35 mm
- 2-pole connecting terminal for
- digital control
- LED power supply unit
- 220-240 V x 0/50-60 Hz
- DC 176-264 V
- DALI-controllable
- Basic insulation is provided between the mains and control cables
- BEGA Thermal Control®
- Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
- Safety class I
- Safety mark
- Conformity mark
- Weight: 2.3 kg
This product contains light sources of energy efficiency class(es) C, D
Safety
- The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
- The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
-
Module connected wattage: 19.2 W
-
Luminaire connected wattage: 22.6 W
-
Rated temperature: ta = 25 °C
-
Ambient temperature: ta max = 45 °C
50 140.2 K3 -
Module designation: 2x LED-0783/930
-
Color temperature: 3000 K
-
Color rendering index: CRI > 90
-
Module luminous flux: 3150 lm
-
Luminaire luminous flux : 1864 lm
-
Luminaire luminous efficiency : 82,5 lm / W
50 140.2 K4 -
Module designation: 2x LED-0783/940
-
Color temperature: 4000 K
-
Color rendering index: CRI > 90
-
Module luminous flux: 3340 lm
-
Luminaire luminous flux : 1976 lm
-
Luminaire luminous efficiency : 87,4 lm / W
Please note:
If the luminaire is to be mounted onto a metallic, electroconductive surface,
it is mandatory to make sure that the mounting surface is connected conductive
to the earth conductor of the luminaire!For replacing the LED module, mounting
and dismantling of the glass please keep a distance of 450 mm above the
luminaire
Installation
LED are high-quality electronic components!
- Please avoid touching the light output openingof the LED directly during installation or relamping.
- Make earth conductor connection to the earthing screw (1) on the reverse side of the glass holder.
- Push silicone sleeves over the lines and make electrical connection.
- For digital control please use the connecting terminal DA, DA.
- In case this terminal is not used the luminaire will be operated at full light output.
- The mounting of the glass holder requires two holes drilled into the wall.
- Fix glass holder with enclosed or any other suitable fixing material onto the mounting surface.
Note : position of application “arrow down”. Insert the synthetic diffuser by sliding into theLED supporting section until the stop. Place glass with its opening over the LED module. The magnet fixes the glass on the glass holder. Align glass vertically
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt
Replacement of the LED module
The designation of the LED module is noted on a label in the luminaire. The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools. Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module. Defective glass must be replaced. Close the luminaire
Spares
- Spare glass 11 003 204 .0B 1RG
- LED power supply unit DEV-0388/700i
- LED module 3000 K LED-0783/930
- LED module 4000 K LED-0783/940
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com