BEGA 24 507 Pendant luminaire Suspension Instructions

June 12, 2024
BEGA

BEGA  24 507 Pendant luminaire Suspension

BEGA-24 507-Pendant-luminaire-Suspension-PRODUCT-IMAGE

Product Information

The product is a pendant luminaire designed for mounting in arcades, galleries, and passageways. It features a shielded light that directs the light downwards in a rotationally symmetrical wide beam. The luminaire is suitable for both interior and exterior applications, but when installed outdoors, it must be protected from constant pendulum movement due to wind.

The installation and operation of the luminaire should comply with national safety regulations. Only qualified electricians should carry out the installation and commissioning. The manufacturer does not accept liability for damage caused by improper use or installation. Any modifications made to the luminaire should be done by a responsible person who will be considered the manufacturer.

The electronic components in the luminaire are protected against overvoltage according to DIN EN 61547 standards. However, for additional protection against transients, it is recommended to use separate overvoltage protection components.

The luminaire is available with different LED modules, each with specific characteristics such as colour temperature, colour rendering index, module luminous flux, luminaire luminous flux, and luminaire luminous efficiency.

Product Usage Instructions

  1. To replace the LED module, refer to the label inside the luminaire for the module designation. BEGA replacement modules have the same light colour and light output as the original modules. Qualified individuals can replace the module using standard tools.
  2. Ensure that the luminaire is mounted securely in arcades, galleries, or passageways using the provided mounting plate.
  3. If installing the luminaire outdoors, make sure it is protected from constant pendulum movement caused by wind.
  4. Comply with national safety regulations during installation and commissioning. Only qualified electricians should perform these tasks.
  5. To protect against overvoltage and transients, consider using separate overvoltage protection components available on the manufacturer’s website.

Pendant luminaire

BEGA-24 507-Pendant-luminaire-Suspension-01

Instructions for use

Application
Pendant with shielded light for mounting in arcades, galleries and passageways.
An integral reflector unit directs the light downwards in a rotationally symmetrical wide beam.
When installed in exterior applications, the luminaire must be protected from constant pendulum movement due to wind.

Product description

  • Luminaire made of aluminum alloy,  aluminum and stainless steel
  • BEGA Unidure® coating technology
  • Safety glass with optical structure
  • Reflector made of pure anodized aluminum 4 drilled holes with thread M4 to which tension cables preventing pendulum movement can be fixed
  • Mounting plate with 2 fixing  holes ø 5.5 mm · 70 mm spacing 2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm, max. 5 G 1.5@ Cable pendant H05RN-F 5 G 1@  with 2 steel cords
  • Colour black
  • Connecting terminal 2.5@  with plug connection
  • Earth conductor connection
  • BEGA Ultimate Driver®
  • LED power supply unit 220-240 V x 0/50-60 Hz
  • DC 176-264 V
  • DALI-controllable
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets Impact strength IK06
  • Protection against mechanical impacts < 1 joule
  • Safety mark
  • CE: Conformity mark
  • Weight: 5.6 kg

This product contains light sources of energy efficiency classes C

Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to
the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

BEGA-24 507-Pendant-luminaire-Suspension-02

Installation

  • For mains supply connection open the mounting box.
  • Release steel cord 3 by pushing the bushing of the cord spanner.
  • If required on site, the steel wire 1 fixed to  the back of the mounting plate must be  firmly secured to a non-flammable building component.
  • Fix end of steel cord 1 on the back of mounting plate 2 with hexagon socket head screw
  • M5. Lead mains supply cable through the compression nipple into mounting plate. Fix mounting plate with enclosed or any other suitable fixing material onto the mounting surface.
  • It is absolutely essential to use the enclosed gaskets.
  • Make earth conductor connection and electrical connection.
  • The two loose plug-in terminals marked DALI are provided for digital control purposes.
  • If these wires are not assigned, the luminaire will work with full light output.
  • Insert steel cord 3 into cord spanner up to the stop.
  • Make earth conductor connection between mounting box and mounting plate.
  • Push plug into coupler up to the stop.
  • Make sure that the gasket is in correct position. Bolt mounting box firmly onto mounting plate.

To shorten the cable pendant

  • The cable must only be shortened within the mounting box. By pushing the bushing of the cord spanner the steel cord 3 is released. Disconnect mains supply cable from plug connection and earth conductor
  • terminal. Loosen locking screws – hexagon socket head screws M4 – for suspension cord.
  • Pull suspension cords out of lock holes. Screw off round nut 4 and pull cable with gasket out of screw connection. Shorten cable to the desired length.
  • Insert pressure disk into the round nut and press gasket into the round nut. Grease connecting cable somewhat and lead it through round nut and gasket. Tighten round nut as far as it will go and screw it together  with the mounting box. Strip lines and pull  suspension cords tightly into the lock holes at the cord holder.
  • Tighten locking screws M4 firmly.
  • Shorten steel cords with excess length, protect with end sleeves.
  • Lay steel cord 3 around the cord holder in such a way that steel cord 3 is led between the cord holder and the two suspension cords of the cable pendant.

Lamp

  • Module connected wattage 35.3 W
  • Luminaire connected wattage 39 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 35 °C

24 507 K3

  • Module designation LED-0770/830
  • Colour temperature 3000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 6675 lm
  • Luminaire luminous flux 4294 lm
  • Luminaire luminous efficiency 110,1 lm / W

24 507 K4

  • Module designation LED-0770/840
  • Colour temperature 4000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 6865 lm
  • Luminaire luminous flux 4416 lm
  • Luminaire luminous efficiency 113,2 lm / W

Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
Disconnect the electrical installation.
Undo the hexagon socket screws (wrench size 3 mm) at the mounting box and remove the pendant luminaire.

Disconnect plug connection.
Undo the hexagon socket screws (wrench size 5 mm) at the luminaire top and remove luminaire housing.
Undo 4 hexagon socket screws (wrench size 5 mm) in the luminaire housing (keyholes), turn LED-unit counter-clockwise and pull it out of the luminaire housing.
For relplacing the LED module undo the hexagon socket screws (wrench size 3 mm) and lift cover of the LED-unit.
Please follow the installation instructions for the LED module.
Assembly to be carried out in reverse sequence.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.

Spares

  • Spare glass 14 001 228
  • LED power supply unit DEV-0270/1050
  • LED module 3000 K LED-0770/830
  • LED module 4000 K LED-0770/840
  • Reflector 76 001 574
  • Gasket mounting box 83 001 903

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals