BEGA 84 910 Mortise Lamp Outdoor Instructions
- June 12, 2024
- BEGA
Table of Contents
In-ground luminaire RGBW
84 910
Instructions for use
Application
Recessed location luminaire for recessed mounting in compacted surfaces, paths
and open areas. Drive-over luminaire for vehicles with pneumatic tyres.
The luminaire can be controlled by DALI colour light control (DT 8, RGBWAF,
xy).
We recommend the use of BEGA DALI system components.
Please note:
Luminaire must not be used for installation in road lanes, where the fixture
is exposed to a horizontal strain due to braking, acceleration and change of
direction.
For walk-through public areas, we recommend skid-blocking glass – see
accessories.
Lamp
Module connected wattage | 10 W |
---|---|
Luminaire connected wattage | 12 W |
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 45 °C |
When installed in heat-insulating material | ta max = 35 °C |
Module designation | LED-1215/RGBW |
Colour temperature of the white LED | 4000 K |
Luminaire luminous flux | 408 lm |
Luminaire luminous efficiency | 34 lm / W |
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
We recommend fuse protection via a residual current circuit breaker to be
provided by the customer.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Product description
Luminaires and installation housings made of highly corrosion-resistant
aluminium BEGA Tricoat® coating technology
Frame made of glass fibre reinforced synthetic material
Cover frame made of stainless steel, steel grade number 1.4301
Recess housing with cable entry for cable conduit, max ø 20 mm
Safety glass, white
1,8 m water-resistant connecting cable
07RN8-F 5 G 1@ with implemented water
stopper and 1.2 m PVC cable conduit
BEGA Ultimate Driver®
LED power supply unit 220-240 V x 0/50-60 Hz DC 176-264 V
DALI controllable (DT8, RGBWAF, xy) A basic isolation exists between power
cable and control line
BEGA Thermal Control
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire
Safety class I
Protection class IP 68 10 m
Dust-tight and water pressure tight
Maximum submersion depth 10 m
Pressure load 5,000 kg (~50 kN)
Impact strength IK10
Protection against mechanical
impacts < 20 joule
Maximum surface temperature 30 °C
(measured according to EN 60598 of ta 15 °C)
****– Conformity mark®
– Safety mark
Weight: 5.6 kg
This product contains light sources of energy efficiency classes F
Notice prior to installation:
To accept the maximum pressure load of 5,000 kg (~50 kN) a proper foundation
must be provided by the customer.
The luminaire is mounted in a recess housing made of high-strength aluminium
profile.
The pressure load is transferred to the foundation by this housing. Foundation
to be provided at site. The foundation must be carried out on firm subgrade.
In order to obtain a firm stableness, the recess housing must be firmly
concreted in.
During preperation of the foundation proper drainage must be provided, so that
entering surface water can drain off.
The lacquering of the recess housing must not be damaged.
For the tightness of the luminaire it is important that the ground surface
prepared later is either on the same level or slightly below top edge of the
recess housing – see sketch (detail A).
Soil conditions :
The luminaire must not permanently have contact with aggressive media.
Aggressive media might be washed out of the soil and might corrode the housing
of the luminaire.
In case of an unknown composition of the soil a soil analysis should be made
before installation. Aggressive media that is outgoing from the ground surface
might also affect the luminaire.
Thus an overuse of de-icing agents in the surroundings should be avoided.
Parasitic current, occuring from the outside, which is conducted by the
luminaire into the soil, will cause corrosion damage.
Suitable counter measures must be carried out.
Installation
Dismantle luminaire from the recess housing.
For this purpose undo screws in the stainless steel frame. Lift luminaire out
of the recess housing.
Position recess housing on the foundation (as described above) and fix it with
enclosed or any other suitable fixing material.
A customer-provided connecting sleeve outside of the installation housing is
required to connect the luminaire to the power supply.
We recommend to use a BEGA distribution box 70 730.
Pass the protective cable conduit from the connecting sleeve into the
installation housing.
Pass the connection cable through the protective conduit and connect it
securely to the underground cable.
Note correct configuration of the mains supply cable. Make mains supply
connection at the brown (L), blue (N) and green-yellow lead ( ).
The connection of the control cables is achieved by means of the both leads
marked with DALI.
In case these leads are not used the luminaire will be operated at full light
output.
0.3 m of cable is provided in the installation housing so that the luminaire
may be removed.
Insert the lamp housing into the outer housing.
Tighten locking screws firmly.
Torque = 3.7 Nm.
Replacing the LED module · Maintenance
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
We recommend replacing the built-in seals and desiccant bag if the luminaire
has to be opened for maintenance purposes.
Article numbers are listed in the Replacements section.
Disconnect the electrical installation.
Clean the key opening in the bolt head from dirt and other residue. Do not use
high pressure cleaners. Only use solvent-free cleaning agents for cleaning the
luminaire.
Loosen and remove the bolts from the stainless steel frame.
Lift the luminaire from the installation housing.
The flexible connecting cable with water stop must be checked for external
damage and must only be replaced with a BEGA connection cable with water stop.
Loosen the hexagon nuts (wrench size 8 mm) and lift off the luminaire housing.
Push down the synthetic frame with force to remove the glass and gaskets.
Remove the glass and the gaskets.
Replace LED module. Follow the installation instructions for the LED module.
Remove the 4 countersunk bolts (torx drive T25) and lift off the top of the
housing to replace the power supply unit. Replace the LED power supply unit.
Screw down all parts of the housing evenly. Ensure the correct seating of the
housing gasket.
Check gaskets and replace if necessary.
Place the glass gasket around the glass with the wider side of the seal facing
up as shown in the illustration.
Insert the glass with the stepped side facing up into the luminaire housing
and press down hard.
Make sure that the glass is seated correctly inside the gasket bed.
Pull up the synthetic frame up to the stop.
Insert the two hexagon socket screws with washers into the holes in the
synthetic frame.
Place the stainless steel frame onto the glass step and synthetic frame and
tighten the hexagon nuts evenly in crosswise fashion.
Torque = 3.7 Nm.
Insert the lamp housing into the outer housing.
Tighten locking screws firmly.
Torque = 3.7 Nm.
Cleaning · Maintenance
After installation, the luminaire should first be cleaned. Building dust, residues from contact adhesives, paint splashes and rust film must be completely removed. Never use high pressure cleaners and cleaning implements made of normal steel, steel brushes or steel wool because they cause extraneous rust to form. When using stainless steel cleaners, please read the directions carefully. Cleaning agents containing hydrochloric acid and chlorides should never be used. We recommend cleaning the luminaires regularly.
Accessories
14001409R Skid-blocking glass in accordance with EN ISO 51130 R13 Surface
abrasion in accordance with EN ISO 10545-7: Category II Anti-slip protection
in accordance with
DIN 51097 Class C 70 730 Distribution box for installation in soil with 7
cable entries Connection terminals 5 x 4@
A separate instructions for use can be provided upon request.
Spares
Spare glass | 14 001 424 |
---|---|
Spare glass skid blocking | 14 001 424 R |
LED power supply unit | DEV-0418/100i |
LED module | LED-1215/RGBW |
Gasket glass | 83 001 914 |
Gasket housing | 83 001 959 |
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com