BEGA 12136 Ceiling and Wall Luminaire Instruction Manual

June 12, 2024
BEGA

Ceiling and wall luminaire for indoor use
12 136

BEGA 12136 Ceiling and Wall Luminaire -

Instructions for use

Application
Ceiling and wall luminaire · indoor luminaire made of hand-blown opal glass and metal housing, for all lighting tasks in interior applications. They are ideal for places where a soft and uniform lighting distribution is required.
Luminaire with motion sensor.

Product description

Metal housing, finish Colour white Hand-blown opal glass, satin matt, with bayonet closure Integrated HF-motion sensor, maximum range 10 m
2 mounting holes ø 5.5 mm
Distance apart 180 mm
2 cable entries for through-wiring for mains cable up to ø 10.5 mm max. 3 × 1.5@
Connection terminal 2.5@
Earth conductor connection
LED power supply unit
230 V y 50 Hz
BEGA Thermal Switch®
Temporary thermal shutdown to protect temperature-sensitive components Safety class I
Impact strength IK02
Protection against mechanical impacts < 0.2 joule
****– Conformity mark
Weight: 1.4 kg
This product contains light sources of energy efficiency class(es) D, E

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Lamp

Module connected wattage 8.2 W
Luminaire connected wattage 11.3 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 40 °C

12 136 K27
Colour temperature| 2700 K
Colour rendering index| CRI > 90
Module luminous flux| 1165 lm
Luminaire luminous flux| 603 lm
Luminaire luminous efficiency| 53,4 lm / W
12 136 K3
Colour temperature| 3000 K
Colour rendering index| CRI > 90
Module luminous flux| 1205 lm
Luminaire luminous flux| 624 lm
Luminaire luminous efficiency| 55,2 lm / W

Luminaire with trim ring:
Before installing onto the mounting surface the luminaire housing must be inserted into the trim ring (accessory).

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
Pass the mains supply cable through the grommet into luminaire housing.
Fix luminaire housing with enclosed or any other suitable fixing material on to the mounting surface.
It is imperative to use the enclosed gaskets.
Dismantle the mains supply cable approx. 60 mm.
Make earth and electrical connection to the terminals.
Place glass to the luminaire housing and observe that the cam pins fit into the notches of the glass.
Screw in glass by turning it clockwise.
Thus, you reach a safe and vibrationresistant holding of the glass.
To release the glass from the luminaire housing, turn it counter-clockwise.

BEGA 12136 Ceiling and Wall Luminaire - fig1

The built-in motion sensor operates at a frequency of 5.8 GHz.
By moving within the detection range the motion sensor switches on the LED module inside the luminaire with a defined dwell time –push-button “Dwell time”.
With a wall mounting height of 1.8 m or ceiling mounting height of 2.6 m, the maximum range is 10 meters (see sketch).

BEGA 12136 Ceiling and Wall Luminaire - fig2

The max. wall mounting height is 2.7 m and the max. ceiling mounting height is 4.0 m, in which the range reduces significantly.
The range can be set individually – push-button “Sensitivity”.
It should be noted that metal parts which are mounted in close proximity to the luminaire can affect the range.
With the three integrated push-buttons (Brightness, Dwell time and Sensitivity) on the motion sensor, specific settings can be made.
The first keypress activates the setting function.
Press a push-button to switch each function to the next level, the LED indicator on the motion sensor flashes to confirm.
After reaching the highest level, the level setting begins with “Level 1”.

BEGA 12136 Ceiling and Wall Luminaire - fig3

BEGA 12136 Ceiling and Wall Luminaire - fig4

After the 3 parameters brightness, dwell time and sensitivity have been set successfully the module will require a voltage break to save the changes.
The integrated light sensor can be set individually with the brightness levels on the ambient brightness – Press the button “Brightness”.
Further individual illumination levels can be used with the button “Brightness” and set with the “learning mode”.
Press button “brightness” (> 3 s) to enable the “learning mode”. There is a slow flashing of the LED indicator.
After about two minutes, the current brightness value is measured for one minute, the LED flashes faster.
After completion, the measured brightness value is saved and is available in stage 6 of “Brightness” as the new brightness value.
To simplify the initial operation, the settings have been made as follows:
Range = 75 % (7.5 m)
Dwell time = 10 s
Light sensor = daylight
Factory Reset
The motion sensor can be reset to factory settings (MICAS) by simultaneously pressing the buttons “Sensitivity” and “Dwell time” for about 5 s.
The factory settings are as follows:
Range = 75 % (7.5 m)
Dwell time = 900 s
Light sensor = daylight
Test mode
The test mode can be used to check the change of settings of the motion sensor.
Press button “Sensitivity” (> 3 s) to enable the “test mode”.
Each further keystroke of this push-button prolongs the test mode.
The active test mode is displayed by a flashing of the LED indicator (2 s interval).
After 3 minutes the test mode is automatically disabled.
Replacement of the LED unit
The designation of the LED unit is noted on a label in the luminaire.
The light colour and light output of BEGA replacement units correspond to those of the LED units originally fitted. The LED unit can be replaced by qualified persons using standard tools.
Disconnect from main supply.
Unscrew glass from luminaire housing by turning it counter-clockwise.
Replace the LED unit.
Screw in glass by turning it clockwise.
Defective glass must be replaced.

Accessory · Trim rings

For this luminaire metal trim rings in 3 enamel surfaces are optional available.
Trim rings are accessories and must be ordered separately.

Item Part. No
Colour white 13 001
Colour palladium 13 002
Colour glossy silver 13 003

Spares

Spare glass 11 003 125 .0
HF-motion sensor 61 001 077
LED unit 2700 K 75 003 045 K27
LED unit 3000 K 75 003 045 K3

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com