BEGA 99 356 In Ground luminaire

Application

  • Floodlight for recessed installation in compacted surfaces with ø 30 mm provided by the customer.
  • Drive-over luminaire from vehicles with pneumatic tires.

Please note:
Luminaire must not be used for installation in road lanes, where the fixture is exposed to a horizontal strain due to braking, acceleration and change of direction.

Dimension

BEGA-99-356-In-Ground-luminaire-fig-1

Product Description

  • In-ground LED luminaire without power supply unit
  • Luminaire made of stainless steel
  • Steel grade no 1.4301
  • Installation bush made of polyamide
  • Clear safety glass
  • Reflector surface made of pure aluminium 3 m water-resistant connecting cable 05RN8-F 2 × 1@ with implemented water stopper
  • Safety class III 3
  • Protection class IP 68 20 m
  • Dust-tight and water pressure tight
  • Maximum submersion depth 20 m
  • Not suitable for permanent operation under water
  • Impact strength IK10
  • Protection against mechanical impacts < 20 joule
    • r – Safety mark
    • c – Conformity mark
  • Weight: 0.35 kg
  • This product contains light sources of energy efficiency class(es) C

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Please note:
The luminaire can only be operated with an operating device that fulfills the requirements according to EN 61347-2-13. The maximum idle voltage of 60 V DC must conform to SELV or SELV equivalent.

Lamp

  • Module connected wattage 0.3 W
  • Luminaire connected wattage 0.5 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 60 °C
  • Voltage 24 V = DC

99 356 K27

  • Colour temperature 2700 K
  • Colour rendering index CRI > 80
  • Module luminous flux 45 lm
  • Luminaire luminous flux 29 lm
  • Luminaire luminous efficiency 58 lm / W

99 356 K3

  • Colour temperature 3000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 50 lm
  • Luminaire luminous flux 32 lm
  • Luminaire luminous efficiency 64 lm / W

99 356 K4

  • Colour temperature 4000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 50 lm
  • Luminaire luminous flux 32 lm
  • Luminaire luminous efficiency 64 lm / W

Installation

  • A separate power supply unit is required to operate the luminaire – see accessories.
  • For installation in drilled holes, a recessed opening of ø 30 mm with a minimum depth of 100 mm is required to hold the installation sleeve.
  • Press the installation sleeve firmly into the recessed opening.
  • For installation in paved surfaces, the appropriate installation housing is 70 778 available.
  • In this case, the polyamide installation sleeve is not used.
  • The cable connection must be established on site with the correct protection class and safety class for the luminaire.
  • We recommend that you use distribution box 70 730 or 71 053 for this purpose.
  • To protect the luminaire power supply cable against damage we recommend you to use a PVC conduit on-site.
  • A 24 V safety direct voltage source with a smoothed residual ripple of max. 10 % is required for the electrical connection of the luminaire – see accessories.
  • If other safety direct voltage sources are used, an upstream fuse (max. 6 A) must be provided by the customer.
  • The black wire is to be connected to the negative terminal, the red wire to the positive terminal on the power supply unit.
  • Press the luminaire into the installation sleeve.

Cleaning  And Maintenance

After installation, the luminaire should first be cleaned. Building dust, residues from contact adhesives, paint splashes and rust film must be completely removed. Never use high pressure cleaners and cleaning implements made of normal steel, steel brushes or steel wool because they cause extraneous rust to form. When using stainless steel cleaners, please read the directions carefully. Cleaning agents containing hydrochloric acid and chlorides should never be used. We recommend cleaning the luminaires regularly.

Accessories

Power supply unit for LED luminaires 24 V DC
Safety transformer according to EN 61558/VDE 0570 part 2-6

  • 70 564 Power supply unit for 5-15 W
  • 70 465 Power supply unit for 10-25 W
  • 70 565 Power supply unit for 20-35 W
  • 70 566 Power supply unit for 30-50 W
  • 70 567 Power supply unit for 40-75 W
  • 70 169 Power supply unit for 70-150 W 230 V y 50-60 Hz

70 114 Power supply unit for 0-70 W

  • AC range: AC: 198-264 V y 50-60 Hz
  • DC range: DC: 176-275 V

The power supply units are also suitable for the operation of several LED luminaires. In this case, the maximum wattage of the power supply unit must not be exceeded.

  • 70 778 Installation housing made of stainless steel
  • 70 730 Distribution box for installation in soil with 7 cable entries Connection terminals 5 x 4

For the accessories, separate instructions for use can be provided upon request.

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals