This product is a luminaire that requires installation and operation in accordance with national safety regulations. It is recommended to have a qualified electrician carry out the installation and commissioning. The manufacturer does not accept liability for any damage caused by improper use or installation. The luminaire is equipped with electronic components that are protected against overvoltage according to DIN EN 61547. For additional protection against transients, it is advised to use separate overvoltage protection components.

The product features a lamp module with a connected wattage of 16 W and a luminaire connected wattage of 19.1 W. The rated temperature is not specified, but it is designed to operate within an ambient temperature range of 25 to 35 degrees Celsius. The module designation is LED-0569/930 with a color temperature of 3000 K. The color rendering index (CRI) is greater than 90, and the module luminous flux is 2440 lm. The luminaire luminous flux is 1906 lm, and the luminaire luminous efficiency is 99.8 lm/W.

The product also includes spare parts such as a spare glass, LED power supply unit, and LED module with a color temperature of 3000 K.

Product Usage Instructions

  1. Place the glass onto the luminaire housing.
  2. Ensure that the holding spring bolts fit into the notches of the glass.
  3. Turn the glass clockwise until it is locked, ensuring a safe and vibration-resistant hold.
  4. To release the glass from the luminaire housing, turn it counter-clockwise.

Ceiling and wall luminaire for indoor use

BEGA-34-287-Ceiling-and-Wall-Luminaire-1

Instructions for use

Application
Ceiling and wall luminaire · indoor luminaire made of hand-blown opal glass, satin matt and metal housing, for all lighting tasks.
They are ideal for places where a soft and uniform lighting distribution is required.

Product description

  • Metal housing, finish Colour white

  • Hand-blown opal glass, satin matt, with sliding-bolt closure

  • 2 mounting holes ø 5.5 mm

  • Distance apart 200 mm

  • 2 cable entries for through-wiring for mains

  • cable up to ø 10,5 mm max. 5 x 1.5@

  • Connecting terminal 2.5@ with plug connection

  • Earth conductor connection 2-pole connecting terminal for digital control

  • LED power supply unit 220-240 V x 0/50-60 Hz

  • DC 176-280 V

  • DALI-controllable

  • Number of DALI addresses: 1

  • Basic insulation is provided between the mains and control cables

  • BEGA Thermal Control®

  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire

  • Safety class I

  • Protection class IP 44

  • Protected against granular foreign bodies ≥ 1 mm and splash water

  • Impact strength IK05

  • Protection against mechanical
    impacts < 0.7 joule

  • r – Safety mark

  • c – Conformity mark

  • Weight: 2.7 kg

  • This product contains light sources of energy efficiency class(es) D

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 16 W
  • Luminaire connected wattage 19.1 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 35 °C

34 287 K3

  • Module designation LED-0569/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 2440 lm
  • Luminaire luminous flux 1906 lm
  • Luminaire luminous efficiency 99,8 lm / W

Installation

  • LED are high-quality electronic components!
  • Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Disassemble LED module.
  • Loosen LED-connection and earth connection (plug connection).
  • Dismantle the mains supply cable max. 80 mm.
  • Lead mains supply cable through the cable entry into the luminaire housing.
  • Fix the luminaire housing with enclosed or any other suitable fixing material onto the mounting surface.
  • It is imperative to use the enclosed gaskets.
  • Make earth and electrical connection to the terminal.
  • For digital control please use the 2-pole plug connector DA, DA.
  • In case this connector is not used the luminaire will be operated at full light output.
  • Make earth connection between LED module and luminaire housing (plug connection).
  • Push LED-plugs into couplers as far as it will go.
  • Assemble LED module.
  • Tighten the screws evenly (max. 0,8 Nm).
  • Please observe that the LED module is not damaged mechanically.
  • Insert the opal glass into the luminaire housing with sliding bolt glass closure and turn the glass clockwise up to the stop
  • Place glass to the luminaire housing and observe that the holding spring bolts fit into the notches of the glass.
  • Turn the glass clockwise until it is locked.
  • Thus, you reach a safe and vibration-resistant holding of the glass.
  • To release the glass from the luminaire housing, turn it counter-clockwise.

Replacement of the LED module Maintenance

The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
Disconnect the system.
Unscrew glass from luminaire housing by turning it counter-clockwise.
Clean glass and luminaire regularly with solvent-free cleansers from dirt.
Please follow the installation instructions for the LED module.
Screw in glass by turning it clockwise as far as it will go.
A broken glass must be replaced.

Spares
Spare glass 11 002 770 .0R G
LED power supply unit DEV-0409/700
LED module 3000 K LED-0569/930

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com