BEGA 50 147.1 Wall Washer for Indoor Use Instruction Manual

June 12, 2024
BEGA

BEGA 50 147.1 Wall Washer for Indoor Use

Product Information

Parameter Value
Safety The installation and operation of this luminaire are subject to

national safety regulations. Installation and commissioning may
only be carried out by a qualified electrician. The manufacturer
accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the
luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Overvoltage Protection| The electronic components installed in the luminaire are
protected against overvoltage in accordance with DIN EN 61547. To
achieve an additional protection against e.g. transients, etc. we
recommend separate overvoltage protection components. You can find
them on our website at www.bega.com.
Lamp Module Connected Wattage| 32.8 W
Luminaire Connected Wattage| 37 W
Rated Temperature| Ambient temperature of 25-30°C
Lamp| 32.8 W
Lamp Module Designation| 2x LED-0695/930
Colour Temperature| 3000 K
Colour Rendering Index (CRI)| CRI > 90
Module Luminous Flux| 4830 lm
Luminaire Luminous Flux| 3845 lm
Luminaire Luminous Efficiency| 103.9 lm/W
Module Designation| 2x LED-0695/940
Colour Temperature| 4000 K
Colour Rendering Index (CRI)| CRI > 90
Module Luminous Flux| 5020 lm
Luminaire Luminous Flux| 3990 lm
Luminaire Luminous Efficiency| 107.8 lm/W
Spares| Spare glass, LED power supply unit, LED module 3000 K, LED
module 4000 K, Reflector

Product Usage Instructions

  1. Ensure that the installation and operation of this luminaire are carried out by a qualified electrician in compliance with national safety regulations.
  2. Protect the luminaire against overvoltage by using separate overvoltage protection components. These can be found on our website at www.bega.com.
  3. Connect the lamp module with a wattage of 32.8 W to the luminaire.
  4. The luminaire itself has a connected wattage of 37 W.
  5. Ensure that the ambient temperature does not exceed the rated temperature of 25-30°C.
  6. The lamp module designation is 2x LED-0695/930 with a colour temperature of 3000 K.
  7. The lamp has a colour rendering index (CRI) greater than 90.
  8. The module luminous flux is 4830 lm and the luminaire luminous flux is 3845 lm.
  9. The luminaire has a luminous efficiency of 103.9 lm/W.
  10. The module designation is 2x LED-0695/940 with a colour temperature of 4000 K.
  11. The lamp has a colour rendering index (CRI) greater than 90.
  12. The module luminous flux is 5020 lm and the luminaire luminous flux is 3990 lm.
  13. The luminaire has a luminous efficiency of 107.8 lm/W.
  14. Spare parts available include spare glass, LED power supply unit, LED module 3000 K, LED module 4000 K, and reflector.

DIMENSIONS

Instructions for use

Application

  • Wall washer · indoor luminaire for the glare free illumination of wall surfaces with the mounting surface being the reflection surface. The light emits upwards and downwards.

Product Description

  • Die-cast aluminium and aluminium housing, finish Colour white
  • Crystal glass, inside matt
  • Reflector made of pure anodised aluminium
  • 2 mounting holes ø 4.8 mm
  • Distance apart 265 x 65 mm
  • 2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm, max. 5 G 1.5@ Connection terminal 2.5@
  • Earth conductor connection
  • 2-pole connecting terminal for digital control
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DC 196-250 V
  • DALI-controllable
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • – Safety mark
  • c  – Conformity mark
  • Weight: 2.5 kg
  • This product contains light sources of energy efficiency classes D

Safety

  • The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 32.8 W
  • Luminaire connected wattage 37 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 30 °C

50 147.1 K3

  • Module designation 2x LED-0695/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 4830 lm
  • Luminaire luminous flux 3845 lm
  • Luminaire luminous efficiency 103,9 lm / W

50 147.1 K4

  • Module designation 2x LED-0695/940
  • Colour temperature 4000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 5020 lm
  • Luminaire luminous flux 3990 lm
  • Luminaire luminous efficiency 107,8 lm / W

Installation

  • LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Undo screws and lift off luminaire top. Loosen earth connection (plug connection) and LED-connection between luminaire top and luminaire base.
  • Lead the mains supply cable through the cable entry of the luminaire base.
  • Note position of application of the luminaire “arrow down”.
  • Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface.
  • Be sure to use the gasket rings supplied. Make earth conductor connection.
  • Push silicone sleeves over the lines  and make electrical connection.
  • For digital control please use the connecting terminal DA, DA.
  • In case this terminal is not used the luminaire will be operated at full light output.
  • Make earth connection (plug connection) and LED-connection between luminaire top and luminaire base again.
  • Install luminaire top part, adjust it and tighten screws evenly.

Cleaning · Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The replacement can be carried out by a qualified person using standard tools.
  • Disconnect the system and open the luminaire. Uninstall the reflector.
  • Please follow the installation instructions for the LED module.
  • Install the reflector. Defective glass must be replaced. Close the luminaire.

Replacement of the glass

  • Undo screws and lift off luminaire top. Loosen earth connection (plug connection) and LED-connection between luminaire top and luminaire base.
  • Loosen reflector screws, separate earth connection and remove reflector.
  • Loosen screws of the glass retaining springs and remove glass retaining springs from the luminaire top.
  • Remove damaged glass. Insert replacement glass.
  • Reinstall glass retaining springs and tighten screws on both sides.
  • Insert reflector into luminaire top part, make earth connection to reflector and tighten reflector screws (0,6 Nm).
  • Make earth connection (plug connection) and LED-connection between luminaire top and luminaire base again.
  • Install luminaire top part, adjust it and tighten screws evenly.

Spares
Spare glass 14 001 184 RG
LED power supply unit DEV-0305/700
LED module 3000 K LED-0695/930
LED module 4000 K LED-0695/940
Reflector 76 001 511
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com