BEGA 50 567.1 Ceiling Luminaires Instruction Manual
- June 12, 2024
- BEGA
Table of Contents
BEGA 50 567.1 Ceiling Luminaires
Product Information
Safety: The installation and operation of this luminaire are subject to
national safety regulations. Installation and commissioning may only be
carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
Overvoltage protection: The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve additional protection against transients, it is recommended to use separate overvoltage protection components.
- Module designation: LED-0800/927
- Colour temperature: 2700 K
- Colour rendering index (CRI): > 90
- Module luminous flux: 1665 lm
- Luminaire luminous flux: 1333 lm
- Luminaire luminous efficiency: 98.7 lm / W
- Module designation: LED-0800/930
- Colour temperature: 3000 K
- Colour rendering index (CRI): > 90
- Module luminous flux: 1735 lm
- Luminaire luminous flux: 1389 lm
- Luminaire luminous efficiency: 102.9 lm / W
Product Usage Instructions
- Installation:
- Avoid touching the light output opening of the LED directly during installation or relamping.
- Ensure a secure connection by positioning the luminaire housing precisely in relation to the mounting plate. Make sure the vertical bar inside the housing aligns with the mounting hole on the long bar of the mounting plate. Press the housing firmly against the plate and turn it clockwise until it stops.
- Open Luminaire:
- Unscrew the glass from the luminaire housing by turning it counter-clockwise. Hold the housing in place with one hand to prevent it from turning on the mounting plate.
- Replacement of the LED module:
- The designation of the LED module is noted on a label in the luminaire.
- To replace the module, disconnect the system and open the luminaire. Follow the installation instructions for the LED module provided by the manufacturer.
- If the glass is defective, replace it before closing the luminaire.
Ceiling luminaire for indoor use
Instructions for use
Application
Ceiling luminaire Indoor luminaire with wide beam light distribution.
- Product description Aluminium alloy housing, finish Colour velvet white
- Crystal glass, partially satin matt, with screw neck
- Reflector made of pure anodised aluminium 2 mounting holes ø 4.5 mm
- Distance apart 112 mm
- The luminaire is suitable for through-wiring. Connecting terminals 2.5@
- Earth conductor connection
- LED power supply unit: 220-240 V x 0/50-60 Hz
- DC 176-280 V
- BEGA Thermal Switch®
- Temporary thermal shutdown to protect temperature-sensitive components
- Safety class I
- Impact strength IK06
- Protection against mechanical
- impacts < 1 joule
- Safety mark
- CE: Conformity mark
- Weight: 1.3 kg
This product contains light sources of energy efficiency classes E
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to
the luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at: www.bega.com.
Lamp
- Module connected wattage 11.5 W
- Luminaire connected wattage 13.5 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 30 °C
50 567.1 K27
- Module designation LED-0800/927
- Colour temperature 2700 K
- Colour rendering index CRI > 90
- Module luminous flux 1665 lm
- Luminaire luminous flux 1333 lm
- Luminaire luminous efficiency 98,7 lm / W
50 567.1 K3
- Module designation LED-0800/930
- Colour temperature 3000 K
- Colour rendering index CRI > 90
- Module luminous flux 1735 lm
- Luminaire luminous flux 1389 lm
- Luminaire luminous efficiency 102,9 lm / W
Installation
LED are high-quality electronic components! Please avoid touching the light
output opening of the LED directly during installation or relamping.
Remove mounting plate from the luminaire housing.
Unplug the earth conductor connection (plug contact).
Please note:
If the luminaire is to be mounted onto a metallic, electroconductive surface,
it is mandatory to make sure that the mounting surface is connected conductive
to the earth conductor of the luminaire!
Lead the power connecting cable through the mounting plate.
Fix the mounting plate with enclosed or any other suitable fixing material
onto the mounting surface.
Establish the earth conductor connection to the luminaire housing (plug
contact).
Make earth conductor connection.
Push silicone sleeves over the lines and make electrical connection.
IMPORTANT:
To ensure secure connection, the luminaire housing must be positioned
precisely in relation to the mounting plate.
Make sure that the vertical bar inside the luminaire housing is positioned
precisely in the area of the mounting hole on the long bar of the mounting
plate.
Press the luminaire housing firmly against the mounting plate and turn it
clockwise firmly against the stop.
Open luminaire:
Unscrew glass from luminaire housing by turning it counter-clockwise.
To prevent the luminaire from turning on the mounting plate, hold the
luminaire housing in place with one hand.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacement of the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire. Please follow the installation
instructions for the LED module.
Defective glass must be replaced.
Close the luminaire.
Spares
- Spare glass 11 003 448 10M RG
- LED power supply unit DEV-0150/350
- LED module 2700 K LED-0800/927
- LED module 3000 K LED-0800/930
- Reflector 76 001 796
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com