Instructions for use
Application
Recessed wall luminaire with shielded light distribution for flush or surface
mounted installation.
For glare-free illumination of surfaces from low mounting height.
Product description
Luminaire made of aluminium alloy,
aluminium and stainless steel
BEGA Tricoat® coating technology
Matt safety glass with optical structure
Reflector made of pure anodised aluminium
Recessed opening ø 175mm
Required installation depth 110mm
Fixing is achieved by using two adjustable
wedge-shaped claws
2 cable entries for through-wiring of mains
supply cable ø 7-10.5mm, max. 5G1.5@
Connection terminal 2.5@
Earth conductor connection
LED power supply unit
220-240 V x 0/50-60 Hz
DC 176-276 V
DALI-controllable
Basic insulation is provided between the mains
and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect
temperature-sensitive components without
switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK06
Protection against mechanical
impacts < 1 joule
– Safety mark
– Conformity mark
Weight: 1.5 kg
This product contains light sources of energy
efficiency classes B, C
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend
separate overvoltage protection components.
You can find them on our website at www.bega.com.
Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Lamp
Module connected wattage 7.7 W
Luminaire connected wattage 9.5 W
Rated temperature ta=25 °C
Ambient temperature ta max=50 °C
When installed in heat-insulating
material ta max=40 °C
24 152K3
Module designation LED-0269/830
Colour temperature 3000 K
Colour rendering index CRI >80
Module luminous flux 1515 lm
Luminaire luminous flux 549 lm
Luminaire luminous efficiency 57,8 lm/W
24 152K4
Module designation LED-0269/840
Colour temperature 4000 K
Colour rendering index CRI >80
Module luminous flux 1560 lm
Luminaire luminous flux 565 lm
Luminaire luminous efficiency 59,5 lm/W
Please note:
This luminaire is coated with BEGA Tricoatb.
BEGA Tricoatb is a registered trademark for a technology that we use to
achieve optimal corrosion resistance.
Even the best possible surface protection and the highest corrosion resistance
can be rendered almost ineffective in some cases by aggressive media caused by
leaching of building materials.
Where such media are suspected, a material analysis must be carried out before
installation.
Always avoid excessive use of chemical cleaning agents in the vicinity of the
luminaire.
Installation
The recessed opening is covered by the frame of the luminaire housing.
Fixing of the luminaire in the structure is achieved by using two adjustable
wedge-shaped claws.
Installation in solid, plastered walls:
The installation housing 10 486 is available for this purpose. If this is not
used, an exact recessed opening of ø 175mm with a minimum
depth of 110mm is required.
Installation in exposed brickwork: The construction of an on-site recessed
opening with the exact installation dimensions of ø 175mm with a minimum depth
of 110mm is required. An installation housing cannot be used.
Installation in drywalling:
A recessed opening of ø 175mm with a minimum depth of 110mm is required.
The claws grip behind drywall.
Installation into insulated façades:
For installation in EWIS external wall insulation systems please use
installation housing 13 545 in combination with a plaster frame 10 086 or 13
527.
Undo hexagon socket head screws.
Remove luminaire cover with glued-in glass and LED module
Disconnect plug connection.
Lead the mains supply cable through the cable entry into the luminaire
housing. Make earth conductor connection and electrical connection. For
digital control please use the connecting terminal DALI. In case this
connector is not used the luminaire will be operated at full light output.
In order to guarantee the maximum service life of the electrical components, the enclosed desiccant bag must be placed in the luminaire. Please remove the desiccant bag from the foil packaging and place it in the position marked by the red information label immediately before permanently closing the luminaire.
Make earth conductor connection between luminaire cover and luminaire housing.
Push plug into coupler as far as it will go.
Make sure that gasket is positioned correctly.
Put on luminaire cover and tighten the screws evenly and firmly.
Push luminaire housing into the recessed opening.
Tighten screws claw fastener.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the
LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.
Accessories
10 486 Installation housing
13 545 Installation housing for installation in insulated façades (EWIS)
10 086 Plaster frame
13 527 Plaster frame flush
A separate instructions for use can be provided upon request.
Spares
ED power supply unit DEV-0332/700
LED module 3000 K LED-0269/830
LED module 4000 K LED-0269/840
Gasket 83 001 767
BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden · info@bega.com · www.bega.com