BEGA 33 059 Recessed Wall Luminaire
Product Information
- Product Name: Wall Luminaire
- Light Distribution: Asymmetrical
- Mounting: Flush or Surface
- Application: For glare-free illumination of surfaces from low mounting height
- Overvoltage Protection: The luminaire’s electronic components are protected against overvoltage according to DIN EN 61547. Separate overvoltage protection components are recommended for additional protection.
- Safety: Installation and operation must comply with national safety regulations. Only qualified electricians should carry outinstallation and commissioning. The manufacturer is not liable for damage caused by improper use or installation. Subsequent modifications should be done by the person responsible for them.
- Lamp Module Connected Wattage: 16 W
- Luminaire Connected Wattage: 19 W
- Rated Temperature: 25°C
- Ambient Temperature: 40°C
Product Usage Instructions
- Open the luminaire by undoing the screws and removing the housing cover.
- Disconnect the plug-connection of the LED connecting cable and the earth conductor connection from the plug connection.
- Lead the mains supply cable through the cable entry into the luminaire housing.
- Make the earth conductor connection and the electrical connection.
- If using digital control, use the connecting terminal DA, DA. If not used, the luminaire will operate at full light output.
- To ensure maximum service life of electrical components, place the enclosed desiccant pouch in the luminaire. Remove the desiccant pouch from the foil packaging and place it in the position markedby the red information label before closing the luminaire.
- Connect the LED connection cable using a plug connector.
- Put on the earth conductor connection of the housingcover.
- Assemble the housing cover, making sure the gasket is positioned correctly.
- Tighten the screws evenly.
- Insert the luminaire housing into the recessed opening.
- Tighten the screws of the claw fastener evenly.
Application
Wall luminaire with asymmetrical light distribution for flush or surface
mounting installation.
For glare-free illumination of surfaces from low mounting height.
Product description
- Luminaire made of aluminium alloy, aluminium and stainless steel
- BEGA Tricoat® coating technology
- Clear safety glass
- Silicone gasket
- Reflector made of pure anodised aluminium Fixing is achieved by using two adjustable wedge-shaped claws
- Required recessed opening 405 x 110 mm Recessed depth 90 mm
- 2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm, max. 5 G 1.5@ Connecting terminal and
- earth conductor terminal 2.5@
- BEGA Ultimate Driver®
- LED power supply unit
- 220-240 V x 0/50-60 Hz
- DC 176-276 V
- DALI-controllable
- Basic insulation is provided between the mains and control cables
- BEGA Thermal Control®
- Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
- Safety class I
- Protection class IP 65
- Dust-tight and protection against water jets Impact strength IK10
- Protection against mechanical
- impacts < 20 joule
- – Safety mark
- – Conformity mark
- Weight: 2.4 kg
- This product contains light sources of energy efficiency classes C
Dimension
Overvoltage protection
- The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
- To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
- You can find them on our website at www.bega.com.
Safety
- The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
- The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Lamp
- Module connected wattage 16 W
- Luminaire connected wattage 19 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 40 °C
- When installed in heat-insulating
- material ta max = 35 °C
33 059 K3
- Module designation LED-0573/830
- Colour temperature 3000 K
- Colour rendering index CRI > 80
- Module luminous flux 2795 lm
- Luminaire luminous flux 1756 lm
- Luminaire luminous efficiency 92,4 lm / W
33 059 K4
- Module designation LED-0573/840
- Colour temperature 4000 K
- Colour rendering index CRI > 80
- Module luminous flux 2835 lm
- Luminaire luminous flux 1781 lm
- Luminaire luminous efficiency 93,7 lm / W
Please note
- This luminaire is coated with BEGA Tricoatb.
- BEGA Tricoatb is a registered trademark for a technology that we use to achieve optimal corrosion resistance.
- Even the best possible surface protection and the highest corrosion resistance can be rendered almost ineffective in some cases by aggressive media caused by leaching of building materials.
- Where such media are suspected, a material analysis must be carried out before installation.
- Always avoid excessive use of chemical cleaning agents in the vicinity of the luminaire.
Installation
- The recessed opening will be covered by the frame of the luminaire housing.
- Fixing of the luminaire is achieved by using two adjustable wedge-shaped claws.
Installation in solid, plastered walls:
- The installation housing 10 437 is available for this purpose. If this is not used, an exact recessed opening of 405 x 110 mm with a minimum depth of 90 mm is required.
Installation in exposed brickwork:
- The construction of an on-site recessed opening with the exact installation dimensions of 405 x 110 mm with a minimum depth of 90 mm is required. An installation housing cannot be used.
Installation in drywalling:
- A recessed opening of 405 x 110 mm with a minimum depth of 90 mm is required.
- The claws grip behind drywall.
Installation into insulated façades:
- For installation in EWIS external wall insulation systems pleaseuse installation housing 13 523 in combination with a plaster frame 10 037 or 13 507.
Open luminaire:
- Undo screws and remove housing cover.
- Disconnect plug-connection of the LED connecting cable.
- Disconnect the earth conductor connection from the plug connection.
- Lead the mains supply cable through the cable entry into the luminaire housing.
- Make the earth conductor connection and the electrical connection.
- For digital control please use the connecting terminal DA, DA.
- In case this terminal is not used the luminairewill be operated at full light output.
In order to guarantee the maximum service life of the electrical components, the enclosed desiccant pouch must be placed in the luminaire. Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label immediately before finally closing the luminaire. Connect the LED connection cable by means of a plug connector. Put on earth conductor connection of the housing cover. Assemble housing cover. Make sure that gasket is positioned correctly. Tighten the screws evenly. Insert luminaire housing into the recessed opening. Tighten screws of the claw fastener evenly.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits. Do not use high pressure cleaners.
Replacing the LED module
- The designation of the LED module is noted on a label in the luminaire.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
- The module can be replaced by qualified persons using standard tools.
- Disconnect the system and open the luminaire.
- Please follow the installation instructions for the LED module.
- Inspect and, if necessary, replace the luminaire gaskets.
- Defective glass must be replaced.
- Close the luminaire.
Accessories
- 10 437 Installation housing
- 13 523 Installation housing for installation in insulated façades (EWIS)
- 10 037 Plaster frame
- 13 507 Plaster frame flush
A separate instructions for use can be provided upon request.
Spares
- LED power supply unit DEV-0312/700
- LED module 3000 K LED-0573/830
- LED module 4000 K LED-0573/840
- Reflector 76 001 453
- Gasket 83 001 562
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>