COOPER Lighting Solutions GFLS15FSUNVDBZK Commercial Slim Floodlight
Product Information
Product Name: LED Floodlight
Model Numbers: – GFLS15FSUNVDBZK – GFLM40FSUNVDBZK – GFLL70FSUNVDBZK –
GFLL100FSUNVDBZK
Packaging Contents:
- Light fixture (Part A)
- Photocell (Part B) – 1/2 in. Switch NPS threaded knuckle mount (Part C)
- Knuckle mount lock nut (Part D)
- CCT Switch (Part E)
Required Items (to be purchased separately):
- Philips Screwdriver
- Safety Goggles
- Silicone Sealant
- Wire Strippers / Cutter
- Circuit Tester
- Adjustable Wrench
- Work Gloves
- Ladder
- Power Drill
Safety Instructions
- The product must be installed according to the applicable national electrical code and local building codes by someone familiar with the product and its hazards.
- Before installation or servicing, turn off the power at the circuit breaker or fuse.
- Keep the lamp heads at least 3 inches (76 mm) away from combustible materials.
- Allow the light fixture to cool before touching.
- Do not connect the fixture to a dimmer switch unless it is listed on the dimmer compatibility list.
- Unauthorized changes or modifications to the equipment could void the user’s authorization to operate it.
Mounting Methods:
- Wall Mount
- Eave Mount
- Landscape Post
- Ground Mount
- Dome Cover Plate
Product Usage Instructions
- Before installing the light fixture, ensure that all parts are present and compare them with the included hardware and package contents sections. If any part is missing or damaged, do not attempt to assemble, install, or operate the light fixture.
- Prepare for installation by inspecting the components to ensure that the male and female port threads and sealing surfaces are free of burs, nicks, scratches, or any foreign material.
- Mount the fixture using the Swivel Knuckle into a domed cover plate (not provided) on a junction box or via a landscape post (sold separately)
- If installing two fixtures on one switch, make sure the switch is rated for at least a 1A inductive load.
- If using a dimming switch, use a 0-10V dimmer.
- Turn off the electricity by disconnecting power at the fuse or circuit breaker before installing or servicing.
- Make the electrical connections by following the provided on/off wiring (non-dimming) method. Twist the exposed wires together and secure them using the wire nuts.
- After completing the installation, turn on the electricity and test the light fixture to ensure it is functioning properly. Please refer to the complete user manual for detailed instructions and additional safety information.
LED Floodlight Instructions
Packaging Contents
Hardware Included
ITEMS REQUIRED
(Purchase separately)
- Philips Screwdriver
- Safety Goggles
- Silicone Sealant
- Wire Strippers / Cutter
- Circuit Tester
- Adjustable Wrench
- Work Gloves
- Ladder
- Power Drill
Before installing the light fixture, ensure that all parts are present.
Compare parts with the hardware Included and Package contents sections.
If any part is missing or damaged, do not attempt to assemble, install or
operate this light fixture.
Estimated installation time: 20 minutes
IMPORTANT SAFETY INSTRUCTIONS
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE NATIONAL ELECTRICAL CODE AND LOCAL BUILDING CODES BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
- Please read and understand this entire manual before attempting to assemble, install or operate this light fixture.
- Save these instructions and warnings
- This light fixture requires a 120-277 Volt AC power source. Any other connection voids the warranty.
- Fixture should be installed by persons with experience in household wiring or by a qualified electrician.
- This light fixture must be properly grounded.
- Make sure connections are secure using wire nuts, crimp-on plugs or other UL approved connecting devices.
- This fixture should be installed outdoors to a wall or a pole.
- Disassembling your fixture will void the warranty.
- Always turn OFF the power before adjusting or servicing this light fixture, wear rubber soled shoes and use a wooden or insulated (non-grounded) ladder.
- This product may contain chemicals known to be hazardous. Thoroughly wash hands after installing, handling, cleaning or otherwise touching the product.
READ AND FOLLOW THESE INSTRUCTIONS
WARNING: Before installation or servicing, turn the power OFF at the
circuit breaker or fuse. Place tape over the circuit breaker switch and verify
power is OFF at the light fixture
WARNING : RISK OF FIRE. Keep the lamp heads at least 3 in. (76 mm) from
combustible materials.
CAUTION : BURN HAZARD. Allow the light fixture to cool before touching
NOTICE: Do not connect this fixture to a dimmer switch unless listed on
dimmer compatibility list.
NOTICE: FCC Regulations state that any unauthorized changes or
modifications to this equipment not expressly approved by the manufacturer
could void the user’s authorization to operate this equipment.
IMPORTANT: This device complies with part 15 Class A of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
PREPARING FOR INSTALLATION
IMPORTANT: Domed cover plates for junction boxes, landscape posts, and
other mounting arms and accessories are available.
Please contact the Home Depot customer support.
REVIEW THIS INFORMATION TO ENSURE A SUCCESSFUL INSTALLATION:
- Inspect components to ensure that male and female port threads and sealing surfaces are free of burs, nicks and scratches or any foreign material.
- The fixture must be mounted using the Swivel Knuckle into a domed cover plate (not provided) on a junction box or via a landscape post (sold separately)
- When installing two fixtures on one switch, make sure the switch is rated for at least a 1A inductive load.
- If using a dimming switch, use a 0-10V dimmer.
INSTALLATION
WARNING : Risk of electric shock. Disconnect power at fuse or circuit breaker before installing or servicing.
-
TURN OFF THE ELECTRICITY
- Verify the wall switch is in the OFF position.
- Turn off power at the circuit breaker that supplies power to the outlet box you are working on.
- For screw-in type fuses unscrew the fuse that supplies power to the outlet box you are working on.
-
MAKING THE ELECTRICAL CONNECTIONS
-
If necessary, strip 3/8 in. of insulation from the junction box or fixture (A) wires.
-
Thread the wire through the domed cover plate of the junction box (not provided) or landscape post (not provided).
-
Make wiring connections into the junction box or post by following the wiring instructions below.
ON/OFF WIRING (NON-DIMMING) METHOD: -
Connect the fixture black wire to the house black wire ((+) line), and fixture white wire to the house white wire ((-) common) by twisting the exposed wires together and using the wire nuts (BB). Ensure there are no loose wires.
-
Connect the house ground wire to the green fixture ground wire by twisting the exposed wires together and using the wire nuts (BB)
0-10V DIMMABLE WIRING METHOD: -
Connect the fixture black wire to the house black wire ((+) line), and fixture white wire to the house white wire ((-) common) by twisting the exposed wires together and using the wire nuts (BB). Ensure there are no loose wires.
-
Connect the house ground wire to the green fixture ground wire by twisting the exposed wires together and using the wire nuts (BB).
-
Connect the purple wire to the (V+) DIM wire and the pink wire with (V-) DIM wire by twisting the exposed wire together. NOTE : Hold stripped ends near each other and align any frayed strands (do not twist wires). Push the wires into wire nut (BB) and use your fingers to twist the wire nut clockwise until tight. Check for tightness by pulling wires.
-
-
SECURING THE FIXTURE AND ADJUSTING ORIENTATION
- Secure the fixture to the junction box or landscape post by inserting the threaded swivel knuckle mount (C) into the cover plate or landscape post.
- Place the knuckle mount lock nut (D) on the inside of the domed cover plate and tighten the fixture to the plate.
- If applicable, plug all unused holes and seal threads with silicone.
- Loosen the screw (1) on the swivel portion of the knuckle (C) using a Phillips screwdriver. Adjust the fixture to a suitable orientation, and then tighten the screw (1).
OPERATION
SELECTING DUSK-TO-DAWN OR SWITCH-ACTIVATED MODE
Option 1: Dusk-to-dawn operation
Dusk-to-dawn operation enables the light fixture to automatically turn ON when
dark outside and turn OFF when the sun rises, thus saving you energy.
- To enable dusk-to-dawn operation remove the photocell cap cover (B) and ensure the photocell switch is to ON postion and leave it ON at all times and sure it is unobstructed.
- Ensure the switch powering the outlet connected to the light fixture is turned to the ON position and leave it ON at all times to enable dusk-to-dawn functionality to operate automatically
IMPORTANT: To test if the light fixture (A) and photocell (B) works properly run power to the fixture and cover the photocell to turn fixture ON. Shine a light into the photocell to see if fixture turns OFF.
NOTE: If photocell (B) is located in an area under heavy shade the photocell may not detect enough light and may turn the light fixture ON.
Option 2: Switch-Activated
- Switch Activated operation enables the light fixture to turn ON and OFF by flipping a switch that controls the electricity to the outlet powering the fixture. The light fixture will not turn ON and OFF automatically, but is manually controlled.
- To enable switch activated operation, leave the photocell switch to OFF postion.
SELECTING CCT AND PHOTO-CELL ON/OFF SWITCH
Remove the CCT switch cap E and select the DIP switch to set CCT as your
desired
CARE AND CLEANING
- Shut off the main power supply before cleaning the product. To prolong the original appearance, clean the light fixture with clean water and a soft, damp cloth only.
- Do not use abrasive cleaners or cleaners that contain alcohol. Do not apply paints, solvents or any other chemicals on this light fixture. They could cause a premature deterioration of the finish and may void the warranty.
- Do not spray the light fixture with a hose or power washer.
TROUBLESHOOTING
NOTE: Photocell (B) has a short delay in order to reduce its sensitivity to sudden light changes. When testing, shine a light and cover the photocell for a short time to check if the fixture functions properly.
5-YEAR LIMITED WARRANTY
THE FOLLOWING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES,
WHETHER EXPRESS, IMPLIED OR STATUTORY INCLUDING, BUT NOT LIMITED TO, ANY
WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.
Cooper Lighting Solutions warrants to customers that, for a period of five
years from the date of purchase, Cooper Lighting Solutions products will be
free from defects in materials and workmanship. The obligation of Cooper
Lighting Solutions under this warranty is expressly limited to the provision
of replacement products. This warranty is extended only to the original
purchaser of the product. A purchaser’s receipt or other proof of date of
original purchase acceptable to Cooper Lighting Solutions is required before
warranty performance shall be rendered.This warranty does not apply to Cooper
Lighting Solutions products that have been altered or repaired, that have been
subjected to neglect, abuse, misuse or accident (including shipping damages).
This warranty does not apply to products not manufactured by Cooper Lighting
Solutions which have been supplied, installed, and/or used in conjunction with
Cooper Lighting Solutions products. Damage to the product caused by
replacement bulbs or corrosion or discoloration of brass components are not
covered by this warranty.
LIMITATION OF LIABILITY: IN NO EVENT SHALL COOPER LIGHTING SOLUTIONS BE LIABLE
FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES (REGARDLESS OF THE
FORM OF ACTION, WHETHER IN CONTRACT, STRICT LIABILITY, OR IN TORT INCLUDING
NEGLIGENCE), NOR FOR LOST PROFITS; NOR SHALL THE LIABILITY OF COOPER LIGHTING
SOLUTIONS FOR ANY CLAIMS OR DAMAGE ARISING OUT OF OR CONNECTED WITH THESE
TERMS OR THE MANUFACTURE, SALE, DELIVERY, USE, MAINTENANCE, REPAIR OR
MODIFICATION OF COOPER LIGHTING PRODUCTS, OR SUPPLY OF ANY REPLACEMENT PARTS
THEREFORE, EXCEED THE PURCHASE PRICE OF COOPER LIGHTING SOLUTIONS PRODUCTS
GIVING RISE TO A CLAIM. NO LABOR CHARGES WILL BE ACCEPTED TO REMOVE OR INSTALL
FIXTURES.
To obtain warranty service, please contact Cooper Lighting Solutions at
1-800-334-6871, press option 2 for
Customer Service, or via e-mail at
ConsumerProducts@Cooperlighting.com
and include the following information:
- Name, address and telephone number
- Date and place of purchase
- Catalog and quantity purchase
- Detailed description of problem
All returned products must be accompanied by a Return Goods Authorization
Number issued by the Company and must be returned freight prepaid. Any product
received without a Return Goods Authorization Number from the Company will be
refused. Cooper Lighting Solutions is not responsible for merchandise damaged
in transit. Repaired or replaced products shall be subject to the terms of
this warranty and are inspected when packed. Evident or concealed damage that
is made in transit should be reported at once to the carrier making the
delivery and a claim filed with them. Reproductions of this document without
prior written approval of Cooper Lighting Solutions are strictly prohibited.
For assistance, call 1-800-334-6871 or
e-mail us at
ConsumerProducts@Cooperlighting.com
Printed in China
www.cooperlighting.com
Cooper Lighting Solutions
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
© 2020 Cooper Lighting Solutions
All Rights Reserved
Printed in USA
Imprimé aux États-Unis
Impreso en los EE. UU.
Publication No. IL51879322
August 2022
Cooper Lighting Solutions is a registered trademark.
All trademarks are property of their respective owners.