hama 186353 Weather Station EWS-152 Instruction Manual
- June 6, 2024
- Hama
Table of Contents
- Controls and Displays
- Explanation of Warning Symbols and Notes
- Package Contents
- Safety Instructions
- Warning –Batteries
- Getting Started
- Installation
- Operation
- Manually setting the date/time
- Care and Maintenance
- Warranty Disclaimer
- Technical Data
- Declaration of Conformity
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
186353 Weather Station EWS-152
Operating Instructions
Controls and Displays
A Base station
-
Outdoor temperature
-
Battery symbol
-
Room temperature
-
Time
-
Summertime
-
Wireless symbol
-
button =Increases the current setting/Toggles 12/24 hour format/Manual search for signals from the measuring station
-
MODE button =Settings/Confirms the setting
-
button =Decreases the current setting/Toggles between °C and °F/Activates/deactivates manual radio signal reception
-
Battery compartment
B measuring station -
Transmission indicator lamp
-
Opening for wall mounting
-
Battery compartment
Explanation of Warning Symbols and Notes
Warning
This symbol is used to indicate safety instructions or to draw your attention
to specific hazards and risks.
Note
This symbol is used to indicate additional information or important notes.
Package Contents
- Weather Station EWS-152 (base station for indoor/outdoor measuring station)
- 4AAA batteries
- These operating instructions
Safety Instructions
- The product is intended for private, non-commercial use only.
- Do not operate the product outside the power limits given in the specifications.
- Do not use the product in moist environments and avoid splashes.
- Do not use the product in the immediate vicinity of heaters or other heat sources or in direct sunlight.
- Do not use the product in areas where the use of electronic devices is not permitted.
- Do not place the product near interference fields, metal frames, computers, TVs, etc. Electronic devices and window frames can negatively affect the product’s functionality.
- Don’t drop the product and do not expose it to any major shocks.
- Do not open the device or continue to operate it if it becomes damaged.
- Do not attempt to service or repair the product yourself.Leave any and all service work to qualified experts.
- Keep the packaging material out of the reach of children due to the risk of suffocation.
- Dispose of packaging material immediately according to locally applicable regulations.
- Do not modify the product in any way. Doing so voids the warranty.
- Use the product for its intended purpose only.
- Use the item only in moderate climatic conditions.
- Keep this product, like all electrical products, out of the reach of children!
Warning –Batteries
- When inserting batteries, note the correct polarity (+ and -markings) and insert the batteries accordingly. Failure to do so could result in the batteries leaking or exploding.
- Only use batteries (or rechargeable batteries) that match the specified type.
- Before you insert the batteries, clean the battery contacts and the polar contacts.
- Do not allow children to change batteries without supervision.
- Do not mix old and new batteries or batteries of a different type or make.
- Remove the batteries from products that are not being used for an extended period (unless these are being kept ready for an emergency).
- Do not short-circuit batteries.
- Don’t charge batteries.
- Do not throw batteries in a fire.
- Keep batteries out of the reach of children.
- Never open, damage, or swallow batteries or allow them to enter the environment. They can contain toxic, environmentally harmful heavy metals.
- Immediately remove and dispose of dead batteries from the product.
- Avoid storing, charging, or using the device in extreme temperatures and extremely low atmospheric pressure(for example, at high altitudes).
Getting Started
Measuring station
- Open the battery compartment (13) and insert two AAA batteries with the correct polarity. Close the battery compartment.
Note
Before use, ensure you insert the batteries in the measuring station first and then in the base station.
Base station
- Open the battery compartment (10) and insert two AAA batteries with the correct polarity. Close the battery compartment.
Installation
Note –Installation
-
We recommend initially placing the base and measuring stations in the intended locations without installing them and making all the settings described in 6.
Operating –todo -
Only install the stations once the appropriate settings have been made and a stable wireless connection is established between the stations.
-
Do not mount the product above locations where persons might linger.
Note
- The wireless transmission range between the measuring and base stations is up to 30 min open spaces.
- Before installation, ensurethat wireless transmission will not be disrupted by interference or obstacles like buildings, trees, vehicles, high-voltage lines, etc.
- Before the final installation, ensurethat there is sufficient reception between the intended installation locations.
- When installing the measuring station, ensurethat it is protected from direct sunlight and rain.
- The international standard height for measuring air temperatureis1.25 m(4 ft) above ground.
Warning
- Buy special or suitable installation material from a specialized dealer for wall-mounting.
- Ensure that no faulty or damaged parts are installed.
- Never apply force during installation. This could damage the product.
- Before installation, ensure that the chosen wall is suitable for the weight to be installation, and make sure that there are no electrical wires, water, gas, or other lines at the installation site on the wall.
Base station
- Use the base to position the base station on a level surface.
Measuring station
- You can also position the measuring station on a level outdoor surface.
- We recommend installing the measuring station securely on an outdoor wall using the opening (12). Install an anchor, screw, nail, etc. in the wall of your choice.
- Hang up the base/measuring station using the opening intended for this purpose.
Operation
Note –Input
Hold down the button (7) or the button (9) to select values faster.
Connection to the measuring station
- After you insert the batteries, the base station automatically searches for a connection to the measuring station and performs the initial setup.
Note
- Initial setup takes approx. 3minutes.
- Do not press any buttons during setup. Otherwise, values may not be transmitted correctly and there is a risk of value errors and inaccuracies.
- The setup process is completed when the indoor (3) and outdoor (1) measurement data are displayed.
- If the base station still does not receive a signal from the measuring station, press and hold the button (7) for approx. 3seconds to start the manual search for the signal.
Basic and manual settings
Automatic setting using the DCF signal
- After the base station is switched on for the first time and successful transmission is established between the base station and the measuring station, the clock will automatically search for a DCF signal. During the search, the wireless symbol (6) will flash.
Display| Searching for the DCF signal
---|---
Flashing| Active
Displayed continuously| Successful –signal is being received
No display| Deactivated - If the station still does not receive a signal, press and hold the button (9) for approx. 3seconds to start the manual search for the DCF signal. The wireless symbol (6) will start to flash.
Note –Time settings
- The search process takes about 7minutes. If the search fails, it ends and is repeated at the next clock hour. The wireless symbol (6) will go out.
- In the meantime you can, however, set the time and the date manually.
- The clock automatically continues to search for the DCF signal on daily basis (between 1:00 a.m. and 3:00 a.m.). If the signal is received successfully, the manually-set time and date are overwritten.
Note –Summertime
- The clock automatically switches to summertime. S appears on the display as long as summertime is activated.
- Press and hold the button (9) again for approx. 3seconds to stop the manual search.
Manually setting the date/time
- Press and hold the button (9) for approx. 3seconds to stop the search for the DCF signal. The wireless symbol (6) goes out and you can set the time manually.
- Press and hold the MODE button (8) for approx. 3seconds to start manually setting the date/time.
- Set the following information in the order listed:
- Time zone (difference in hours), hour, minute.
- To select individual values, press the button (7) or the button (9) and confirm each selection by pressing the MODE button (8).
- If you do not make an entry for 20 seconds, you automatically exit setup mode.
Note –Time zone
- The DCF signal can be received over long distances, but always transmits the current Central European Time in Germany. Make sure you account for the time difference in countries with another time zone.
- If you are in Moscow, the time is 3hours later than in Germany. This means that you should set +3 for the time zone. The clock then automatically sets the time to 3hours after the DCF signal is received or relative to the manually set time.
Celsius/Fahrenheit
- Press the button (9) to switch between °C and °F for the temperaturedisplay.
12/24 hour format
- Press the button (7) to switch the time between the 12 and 24 hour format.
Low battery capacity
As soon as the battery symbol (2) appears on the display of the base station,
the capacity of the batteries in the measuring station is very low. Replace
the batteries immediately.
Note –Replacing the batteries
- Note that the stations have to be resynchronized each time after you change the batteries in the measuring or base station.
- To do this, remove the batteries from the other station and then reinsert them, or change them as required.
Care and Maintenance
Only clean this product with a slightly damp, lint-free cloth and do not use aggressive cleaning agents.
Warranty Disclaimer
Hama GmbH &CoKG assumes no liability and provides no warranty for damage resulting from improper installation/mounting, improper use of the product, or failure to observe the operating instructions and/or safety notes.
Technical Data
| Base station| Measuring station
---|---|---
Power supply| 3.0 V
2xAAA batteries| 3.0 V
2xAAA batteries
Power consumption| 0.5 mA| 3 mA
Measuring range Temperature| 0°C –+50°C/
32°F –122°F| -20°C –+60°C/
-4°F –140°F
Measuring increments Temperature| 0.1°C/0.1°F| 0.1°C/0.1°F
Temperature measurement cycle| 43 –47s| 43–47 s
Radio-controlled DCF clock| Yes| No
Frequency| 433 MHz
Range| ≤ 50 m
Declaration of Conformity
Hereby, Hama GmbH &CoKG declares that the radio equipment type [00186353, 00123126] is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.hama.com– > 00186353, 00123126 -> Downloads.
Frequency band(s) | 433 MHz |
---|---|
Maximum radio-frequency power transmitted | 0,015 mW |
Hama GmbH &CoKG
86652 Monheim /Germany
Service &Support
www.hama.com
+49 9091 502-0
www.hama.com/nep
All listed brands are trademarks of the corresponding companies.
Errors and omissions excepted, and subject to technical changes.
Our general terms of delivery and payment are applied.
00186353_00123126/12.19
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>