MINKA LAVERY 2895-691 Chandelier Instruction Manual

October 30, 2023
MINKA LAVERY

 MINKA LAVERY 2895-691 Chandelier

Product Information

The product is a lighting fixture with item number 2895-691, manufactured on August 18, 2021. The fixture is designed to be mounted on a junction box and can support up to five candelabra base bulbs with a maximum wattage of 60 watts each. The fixture includes a mounting plate, ground screw, mounting screws, support cable, canopy, rod, socket cups, and glass shades.

Product Usage Instructions

  1. Before starting the installation process, shut off power at the fuse box or circuit breaker box and remove the old fixture including the mounting hardware.

  2. Unpack the new fixture and lay out all the parts in a clean area. Take care not to misplace any small parts necessary for installation.

  3. Determine the desired hanging height and thread rods (F1, F2, and F3) to all thread (J) on top of the fixture body. Attach the canopy (D) by threading onto rod (F1). Carefully feed wires through each rod as you assemble.
    Note: Remove all thread if installing with one 6 rod only.

  4. Attach mounting plate (A) to the junction box (not included) with mounting screws (B) ( Size: #8-32N*L0.5). The side of the mounting plate (A) marked GND and two convex points must face out.

  5. The support cable is provided to support the weight of the fixture while wiring. Align the fixture to mounting plate (A) and attach hook (P) on the end of support cable (C) to a slot located on mounting plate (A). Carefully allow the support cable (C) to support weight of the fixture while wiring.

  6. Connect the electrical wires as shown in fig 2, making sure that all wire connectors are secured. If your junction box has a ground wire (green or bare copper), connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the mounting plate (A) using the green screw provided.

  7. Tuck wire connectors neatly into the junction box.

  8. Slide canopy (D) over mounting plate (A) and secure with screws (E).

  9. Install five candelabra base bulbs (H) up to 60 watts each or CFL or LED equivalent (not included) in accordance with the fixture specification-

  10. DO NOT EXCEED THE MAXIMUM WATTAGE RATING! (NE PAS DEPASSER LA PUISSANCE NOMINALE MAXIMALE!).

  11. Screw glass shades (I) onto socket cups (G).

  12. Return power to the junction box and test the fixture.

INSTALLATION INSTRUCTIONS

Item#2895-691
(New. 2021/08/18)

READ AND SAVE THESE INSTRUCTIONS

WARNING! SHUT POWER OF FATFUSE OR CIRCUITBREAER .

AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU DISJONCTEUR.

MOUNTING THE FIXTURE (Fig.1)

  1. Shut off power at the fuse box or circuit breaker box and remove the old fixture including the mounting hardware.

  2. Carefully unpack your new fixture and lay out all the parts in a clean area. Take care not to misplace any small parts necessary for installation.

  3. Determine the desired hanging height and thread rods (F1, F2 and F3) to all thread (J) on top of fixture body. Attach canopy (D) by threading onto rod (F1). Carefully feed wires through each rod as you assemble. Note: Remove all thread, if installing with one 6” rod only.

  4. Attach mounting plate (A) to the junction box (Not included) with mounting screws (B) (Size: #8-32N*L0.5”). The side of the mounting plate (A) marked “GND” and two convex points must face out.

  5. The support cable is provided to support weight of fixture while wiring. Align the fixture to mounting plate (A) and attach hook (P) on the end of support cable (C) to a slot located on mounting plate (A). Carefully allow the support cable (C) to support weight of the fixture while wiring.MINKA LAVERY 2895-691 Chandelier-fig-1 CONNECTING THE WIRES (Fig. 2)

  6. Connect the electrical wires as shown in fig 2, making sure that all wire connectors are secured. If your junction box has a ground wire (green or bare copper), connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the mounting plate (A) using the green screw provided.

  7. Tuck wire connectors neatly into the junction box.
    COMPLETING THE INSTALLATION (Fig. 1)

  8. Slide canopy (D) over mounting plate (A) and secure with screws (E).

  9. Install (5) five candelabra base bulbs (H) up to 60 watts each or CFL or LED equivalent (not included) in accordance with the fixture specification—DO NOT EXCEED THE MAXIMUM WATTAGE RATING! (NE PAS DEPASSER LA PUISSANCE NOMINALE MAXIMALE!).

  10. Screw glass shades (I) onto socket cups (G).

Your installation is now complete. Return power to the junction box and test the fixture.

Note: Illustration (Fig.1) on this manual is for installation purposes only. It may or may not be identical to the fixture purchased.