INSTALLATION INSTRUCTIONS
Product Information
- Product Name: Convertible Lamps for Pendant/Semi Flush Mount
- Model Number: 2954-572
- Maximum Wattage Rating: 60 watts per bulb
- Candelabra Base Bulbs: 4 (not included)
- Candle Cover: CCV21058P-613
Product Usage Instructions
-
Before starting the installation, shut off power at the fuse box or circuit breaker box.
-
Remove the old fixture including the mounting hardware.
-
Unpack the new fixture and lay out all the parts in a clean area. Make sure not to misplace any small parts necessary for installation.
-
For Pendant Installation:
a. Place cloth shade (G) and metal washer (E) over all thread (H).
b. Determine the desired hanging height and thread rods (F1, F2, and F3) to the all thread (H).
c. Screw canopy (C) onto rod (F1).
d. Pass the wires carefully through each rod as you assemble.
For Semi Flush Mount Installation:
a. Place cloth shade (G) and metal washer (E) over all thread (H).
b. Secure rod (L) onto all thread (H) and screw canopy (C) onto rod (L).
c. Pass the wires through each part as you assemble. -
Attach the mounting plate (A) to the junction box with mounting screws (B).
-
Connect the electrical wires as shown in fig 2, making sure that all wire connectors are secured. If your junction box has a ground wire (green or bare copper), connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the mounting plate (A) using the green screw provided.
-
Tuck the wire connectors neatly into the junction box.
-
Slide canopy (C) over mounting plate (A) and secure with screws (D).
-
Place candle covers (J) over sockets (I).
-
Install four candelabra base bulbs up to 60 watts each or CFL or LED equivalent in accordance with the fixture specification. Do not exceed the maximum wattage rating.
-
Your installation is now complete. Return power to the junction box and test the fixture.
INSTALLATION INSTRUCTIONS
Item#2954-572 (Convertible Lamps for Pendant)
(New 2021/08/18)
READ AND SAVE THESE INSTRUCTIONS
WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER.
PREPARATION (Fig. 1)
-
Shut off power at the fuse box or circuit breaker box and remove the old fixture including the mounting hardware.
-
Carefully unpack your new fixture and lay out all the parts in a clean area. Take care not to misplace any small parts necessary for installation.
-
Place cloth shade (G) and rnetal washer (E) over all thread (H). Determine the desired hanging height and thread rods (Fl, F2 and F3) to the all thread (H). screw canopy (C) onto rod (Fl). Pass the wires carefully through each rod as you assemble.
-
Attach rnounting plate (A) to the junction box (not included) with mounting screws (B) (Size: The side of the mounting plate (A) with “GND” marked on it and two convex points must face out.
CONNECTING THE WIRES (Fig. 2) -
Connect the electrical wires as shown in fig 2, making sure that all wire connectors are secured. If your junction box has a ground wire (green or bare copper), connect the fixture’s ground wire to it Otherwise, connect the fixture’s ground wire directly to the mounting plate (A) using the green screw provided.
-
Tuck the wire connectors neatly into the junction box.
COMPLETING THE INSTALLATION (Fig. 1) -
Slide canopy (C) over mounting plate (A) and secure with screws (D).
-
Place candle covers (J) over sockets (l).
-
Install (4) four candelabra base bulbs (K) up to 60 watts each or CFL or LED equivalent (not included) in accordance with the fixture specification—DO NOT EXCEED THE MAXIMUM WATTAGE RATING! (NE PAS DEPASSER LA PUISSANCE NOMINALE MAXIMALE!)
Your installation IS now ccmplete_ Retum pwer to juncton tu•x and test the
fixture.
Note: Illustration (Fig. I) on this manual is installation purpoms only.
It may or may not identical to the fixture purchased.
PREPARATION (Fig. 3)
-
Shut off power at the fuse box or circuit breaker box and remove the old fixture including the mounting hardware.
-
Carefully unpack your new fixture and lay out all the parts in a clean area. Take care not to misplace any small parts necessary for installation.
-
Place cloth shade (G), metal washer (E) over all thread (H). Secure rod (L) onto all thread (H) and screw canopy (C) onto rod (L). Pass the wires through each part as you go. Cut wire to leave 7″ of wire after the canopy.
-
Attach mounting plate (A) to the junction box (not included) with mounting screws (B) (Size: The side of the mounting plate (A) with “GND” marked on it and two convex points must face out.
CONNECTING THE WIRES (Fig. 2) -
Connect the electrical wires as shown in fig 2, making sure that all wire connectors are secured. If your junction box has a ground wire (green or bare copper), connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the mounting plate (A) using the green screw provided.
-
Tuck the wire connectors neatly into the junction box.
COMPLETING THE INSTALLATION (Fig. 3)
-
Slide canopy (C) over mounting plate (A) and secure with screws (D).
-
Place candle (J) over sockets (l).
-
Install (4) four candelabra base bulbs (K) up to 60 watts each or CFL or LED equivalent (not included) in accordance with the fixture specification—DO NOT EXCEED THE MAXIMUM WATTAGE RATING! (NE PAS DEPASSER LA PUISSANCE NOMINALE MAXIMALE!)
Your installation is now complete. Return power to the junction box and test
the fixture.
Note: Illustration (Fig. 3) on this manual is for installation purposes
only. It may or may not be identical to the fixture purchased.