PRODUCT

Product Information

The product is a semi-flush mount light fixture, available in two sizes – 66A and 84. The item number for the product is 3997-66A/3997-84. The package contains a mounting plate, ground screw, mounting screws, canopy, finials, and metal rings. The fixture requires three medium base bulbs of up to 60 watts each or CFL or LED equivalent (not included). The fixture should not exceed the maximum wattage rating.

Product Usage Instructions

  1. Turn off power at the fuse box or circuit breaker box and remove the old fixture including the mounting hardware.
  2. Unpack the new fixture carefully and lay out all the parts in a clean area. Take care not to misplace any small parts necessary for installation.
  3. Screw center rod (H) to the top of all thread (G1) of fixture body (I).
  4. Secure all thread (G) of the canopy (C) into the center rod (H).
  5. Thread mounting screw (D) into pre-drilled holes in mounting plate (A) spaced the same distance apart as holes in the canopy (C). The length of mounting screws (D) may be adjusted if necessary. Attach mounting plate (A) to junction box using junction box screws (B). The side of the mounting plate marked GND must face out.
  6. Connect the electrical wires as shown in Fig 2, making sure that all wire connectors are secured. If your junction box has a ground wire (green or bare copper), connect the fixture’s ground wire to it. Otherwise, connect the ground wire directly to the mounting plate (A) using the green screw (E) provided. Tuck wire connectors neatly into the junction box
  7. Place canopy (C) over the mounting plate (A) and secure with two finials (F) onto mounting screws (D).
  8. Unscrew the metal rings (K) from the sockets and place the glasses (J) over the sockets, then secure them with the metal rings (K).
  9. Install three medium base bulbs (L) up to 60 watts each or CFL or LED equivalent (not included) in accordance with the fixture Shade#G3993-2 for 84 specifications–DO NOT EXCEED THE MAXIMUM WATTAGE RATING! (NE PAS DEPASSER LA PUISSANCE NOMINALE MAXIMALE!) Your installation is now complete. Return power to the junction box and test the fixture.

Note : The illustration in the manual (Fig. 1) is for installation purposes only. It may or may not be identical to the fixture purchased. The fixture should be installed by a qualified electrician to ensure proper wiring and installation.
WARNING! SHUT THE POWER OFF AT THE FUSE OR CIRCUIT BREAKER.

INSTALLATION INSTRUCTIONS

  1. Shut off power at the fuse box or circuit breaker box and remove the old fixture including the mounting hardware.

  2. Carefully unpack your new fixture and lay out all the parts in a clean area. Take care not to misplace any small parts necessary for installation.
    ASSEMBLING THE FIXTURE (Fig.1)MINKA-LAVERY-3997-66A-3997-84-Beckonridge-3
-Light-Flush-Mount-FIG-3 \(1\)

  3. Screw center rod (H) to top of all thread (G1) of fixture body (I).

  4. Secure all thread (G) of the canopy (C) into center rod (H).

  5. Thread mounting screw (D) into pre-drilled holes in mounting plate (A) spaced the same distance apart as holes in the canopy (C). Length of mounting screws (D) may be adjusted if necessary. Attached mounting plate (A) to junction box (Not included) using junction box screws (B). The side of mounting plate marked “GND” must face out.
    CONNECTING THE WIRES (Fig. 2)MINKA-LAVERY-3997-66A-3997-84-Beckonridge-3
-Light-Flush-Mount-FIG-3 \(2\)

  6. Connect the electrical wires as shown in fig 2, making sure that all wire connectors are secured. If your junction box has a ground wire (green or bare copper), connect the fixture’s ground wire to it. Otherwise, connect the ground wire directly to the mounting plate (A) using the green screw (E) provided.

  7. Tuck wire connectors neatly into the junction box.
    COMPLETING THE INSTALLATION (Fig. 1)

  8. Place canopy (C) over the mounting plate (A) and secure w two finials (F) onto mounting screws (D).

  9. Unscrew the metal rings (K) from the sockets and place the glasses (J) over the sockets, then secure with the metal rings (K).

  10. Install (3) three medium base bulbs (L) up to 60 watts each or CFL or LED equivalent (not included) in accordance with the fixture specification—DO NOT EXCEED THE MAXIMUM WATTAGE RATING! (NE PAS DEPASSER LA PUISSANCE NOMINALE MAXIMALE!)
    Your installation is now complete. Return power to the junction box and test the fixture.
    Note : The illustration (Fig. 1) on this manual is f installation purposes only. It may or may not be identical to the fixture purchased.
    IMPORTANT : THE FIXTURE SHOULD BE INSTALLED BY A QUALIFIED ELECTRICIAN TO ENSURE PROPER WIRING AND INSTALLATION.

Hardware Bag

MINKA-LAVERY-3997-66A-3997-84-Beckonridge-3-Light-Flush-
Mount-FIG-3 \(3\) MINKA-
LAVERY-3997-66A-3997-84-Beckonridge-3-Light-Flush-Mount-FIG-3
\(4\)

  • A. Mounting plate*1
  • B. Junction Box Screw*2
  • C. Canopy *1
  • D. Mounting screw*2
  • E. Ground screw*1
  • F. Finial*2

Item#3997-66A/3997-84(Semi-Flush Mount)

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MINKA LAVERY User Manuals

Related Manuals