  1. The main switch button(Button 1) controls the switch of the light and fan
  1. When the light or fan is turned off, press the main switch and the fan will run in the memory gear. The light will turn on the memory brightness; If the time difference between turning on and off the light is less than 8 seconds, the color temperature will change; The time difference is greater than 8 seconds, and the color temperature remains the same as the last memory.
  2. Turn on the light or fan, press the main switch to stop the fan and turn off the light; When the power is cut off and the lights are turned on again, the brightness and color temperature are in the state before turning off the lights; Press and hold this button for 3 seconds after turning on for 30 seconds to complete remote control code checking. Successful code matching, flashing light indicates.
  1. The forward and reverse buttons (button2)control the forward and reverse rotation of the fan
  1. When the forward direction is running and a reverse command is received, the fan stops for 5 seconds before starting the reverse.
  2. On the contrary, after the fan stops for 5 seconds, it starts to rotate forward.
  3. After reversing, run in the original gear.
  4. After pressing the front and back car switch buttons, the fan stops for 5 seconds and starts the reverse function. At this time, the fan will adjust the torque of the fan start and vibrate back and forth, which is a normal phenomenon.
  1. Fan gear control button(button3): divided into 7 gears: 6, 5, 4, 3, 2, 1, and off.
  1. Press the gear button when the fan is turned off, and the fan will run at the speed of the gear before turning off the fan.
  2. Fan gear control sequence: Right click to upshift, left click to downshift, maximum of 6 gears, minimum fan off.
  3. Each gear conversion time can respond in real-time, less than 3 seconds.
  4. Require the fan speed to be within 5% of the set speed range.
  1. Brightness and color temperature reuse key(Button4):
  1. Brightness: The brightness can only be adjusted when the LED light is turned on.
  2. To adjust from the darkest to the brightest or from the brightest to the darkest, press and hold for about 10 seconds.
  3. When the button is pressed for a long time (the remote control defines a maximum of 10 seconds), the brightness will gradually increase or decrease. When it reaches the brightest or darkest point, the control board will no longer receive adjustment instructions.
  4. Control pattern: gradually brighten ->gradually brighten ->reach maximum brightness; Gradually getting darker ->gradually getting darker ->reaching darker; When reaching the brightest or darkest, no longer adjust. After releasing the remote control, you can continue to adjust the brightness in reverse.
  5. The minimum power for dimming is 20% of the rated power of the light source. If the rated power of the light source is 18W, the minimum power for dimming is 18 * 20%=3.6W. (Power to light up when the fan is not turned on)
  6. Color temperature: The color temperature can only be adjusted when the LED light is turned on. There are three color temperatures available: white light, light yellow, and yellow light.
  7. The color temperature can be adjusted within 8 seconds of the LED light switching time difference. Press the button once to turn off the light and then press it again to turn it on. The color temperature will be adjusted within 8 seconds of the time difference between the two.
  1. Fan timing button(button5): The timing function is divided into three time periods: 1H, 2H, and 4H
  1. The timing can only be set when the fan is turned on.
  2. When the scheduled time is up, the fan and LED lights will be turned off.
  3. When operating the timed cancellation command or simultaneously turning off the fan and light, the timed setting will be cancelled.
  4. Control sequence: 1H (LED1 flashes once) ->2H (LED2 flashes once) – >4H (LED3 flashes once) ->Cancel timing Loop.
  1. Security launch function
    Press and hold the main switch for 5 seconds before the fan stops, the transmitter indicator light flashes 3 times, and the LED light continues to light up for 60 seconds before turning off.

  2. Other

  1. Control board receiving response distance: no partition, within 10 meters, in any direction.
  2. Power off to save the fan status. After re powering on, the fan is in the pre power off state.
  3. Power off to save the switch, brightness, and color temperature status of the light. After re powering on, the light is in the pre power state.
  4. The default factory state is to turn off the fan, and the light is on with maximum brightness.
  5. Code matching method: Press and hold the main switch button for 3 seconds after turning on for 30 seconds.
  6. The standby power is less than 1W.
  7. Fixed frequency testing mode, press and hold the main switch and color temperature keys before powering on, the indicator light will flash, and enter the fixed frequency testing mode.

FCC Information and Copyright

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

15.19 Labelling requirements.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
FCC RF warning statement: the device has been evaluated to meet general RF exposure requirement , The device can be used in portable exposure condition without restriction.

Shenzhen C D Electronics Co Ltd Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals