This product is a light fixture with a chain loop designed for indoor use. It comes with a mounting plate, canopy, rod, support cable, loop, quick link, and screws for installation. The fixture can accommodate one medium base bulb up to 60 watts or CFL/LED equivalent.

Product Usage Instructions

  1. Before installation, shut off power at the fuse box or circuit breaker box and remove the old fixture including the mounting hardware.
  2. Unpack the new fixture carefully and lay out all the parts in a clean area, taking care not to misplace any small parts necessary for installation.
  3. Secure rod (J) onto all thread (I) on the fixture body.
  4. Determine the desired hanging height and thread rods (F1, F2, and F3) to all threads on rod (J). Screw loop (H1) to rod (F1). Pass the wires carefully through each rod as you assemble.
  5. Attach quick link (G) to loop (H1) and loop (H2) on canopy (D). Carefully feed the wire through the loop (H1), quick link (G), and loop (H2).
  6. Attach mounting plate (A) to the junction box with mounting screws (B). The side of the mounting plate (A) with GND marked on it and two convex points must face out.
  7. Align the fixture to mounting plate (A) and attach hook (P) on the end of support cable (C) and a slot located on mounting plate (A). Carefully allow the support cable (C) to support the weight of the fixture while wiring.
  8. Connect the electrical wires as shown in Fig 2, making sure that all wire connectors are secured. If your junction box has a ground wire (green or bare copper), connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the mounting plate (A) using the green screw provided.
  9. Tuck the wire connectors neatly into the junction box.
  10. Slide canopy (D) over the mounting plate (A) and secure with screws (E).
  11. Install one medium base bulb (K) up to 60 watts each or CFL or LED equivalent (not included) in accordance with the fixture specification–DO NOT EXCEED THE MAXIMUM WATTAGE RATING!
  12. Your installation is now complete. Return power to the junction box and test the fixture.

INSTALLATION INSTRUCTIONS

Item# 2531-695 (New. 2022/04/29)
READ AND SAVE THESE INSTRUCTIONS

PREPARATION (Fig. 1)

  1. Shut of power at the fuse box or circuit breaker box and remove the old fixture including the mounting hardware.

  2. Carefully unpack your new fixture and lay out all the parts in a clean area. Take care not to misplace any small parts necessary for installation.
    ASSEMBLING THE FIXTURE WITH CHAIN LOOP (Fig.1 &Fig. 3)

  3. Secure rod (J) onto all thread (I) on the fixture body.

  4. Determine the desired hanging height and thread rods (F1, F2, and F3) to all threads on rod (J). Screw loop (H1) to rod (F1). Pass the wires carefully through each rod as you assemble.

  5. Attach quick link (G) to loop (H1) and loop (H2) on canopy (D). Carefully feed the wire through the loop (H1), quick link (G), and loop (H2).

  6. Attach mounting plate (A) to the junction box (not included) with mounting screws (B) (Size: #8-32N*L0.5”). The side of the mounting plate (A) with “GND” marked on it and two conve points must face out.

  7. The support cable is provided to support the weight of the fixture while wiring. Align the fixture to mounting plate (A) and attach hook (P) on the end of support cable (C) and a slot located on mounting plate (A). Carefully allow the support cable (C) to support the weight of the fixture while wiring.
    CONNECTING THE WIRES (Fig. 2)

  8. Connect the electrical wires as shown in fig 2, making sure that all wire connectors are secured. If your junction box has a ground wire (green or bare copper), connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the mounting plate (A) using the green screw provided.

  9. Tuck the wire connectors neatly into the junction box..
    COMPLETING THE INSTALLATION (Fig. 1)

  10. Slide canopy (D) over the mounting plate (A) and secure with screws (E).

  11. Install (1) one medium base bulb (K) up to 60 watts each or CFL or LED equivalent (not included) in accordance with the fixture specification—DO NOT EXCEED THE MAXIMUM WATTAGE RATING! (NE PAS DEPASSER LA PUISSANCE NOMINALE MAXIMALE!).

Your installation is now complete. Return power to the junction box and test the fixture.
Note : The illustration (Fig. 1) in this manual is for installation purposes only. It may or may not be identical to the fixture purchased.

Hardware Bag

  • A. Mounting Plate *1

  • B. Mounting Screw*2

  • D. Canopy *1

  • E. Screw*2

  • G. Quick Link*1

  • H. Loop*2

  • F1. ROD 12″*1

  • F2. ROD 12″*2

  • F3. ROD 6″*1