Instruction Manual
Application
Wall luminaire for many lighting tasks on or in buildings.
A luminaire with antique glass diffuser for brilliant light.
Product description
Luminaire made of aluminium alloy,
aluminium and stainless steel
BEGA Unidure® coating technology
Antique glass
Wall mounting with a mounting plate made of stainless steel, Steel grade
number 1.4301 Mounting plate with 2 fixing
holes o 5mm 70mm spacing
1 cable entry for mains supply cable
up to o 10,5mm
Connecting terminals 2.5′ Earth conductor connection Lampholder E 27
Safety class I
Protection class IP 44
Protected against granular foreign bodies
1 mm and splash water Impact strength IK02 Protection against mechanical
impacts < 0.2 joule
– Safety mark
– Conformity mark Weight: 2.2 kg
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Lamp
Luminaire with screw base E 27
Lamp output max. 60 W
This product contains light source of energy efficiency class E
Supplied lamp
BEGA LED lamp 13 584
LED Retrofit 7 W · 805 lm · 3000 K
Luminaire efficiency: 46%
Additional BEGA LED lamps are available for this luminaire:
13 586 LED 7 W · 805 lm · 3000 K dimmable
13 588 LED 8 W · 1055 lm · 3000 K
13 590 LED 12 W · 1400 lm · 3000 K
13 592 LED 12 W · 1400 lm · 3000 K dimmable
Radio-controlled version (Zigbee 3.0):
13 555 LED 9 W · 805 lm · 2700 K dimmable
13 556 LED 9 W · 805 lm · 2700 – 6500 K dimmable · tunable white
13 557 LED 9.5 W · 805 lm · 2700 – 6500 K dimmable · tunable white · RGBW
Detailed technical and lighting data for the lamps can be found in the data sheets on our website.
Installation
Undo screw at wall box and remove the mounting plate.
Lead the mains supply cable through the cable entry of the mounting plate.
Note position of application of the mounting plate “arrow down”.
Fix the mounting plate with enclosed or any other suitable fixing material
onto the mounting surface.
Make the earth conductor connection and the electrical connection.
Make earth conductor connection between luminaire housing and mounting plate.
Note position of application of the luminaire “arrow down”.
Place the luminaire onto the mounting plate, adjust and fix it.
Open luminaire:
Undo cone adaptor at luminaire roof.
Insert lamp.
In case a compact fluorescent lamp is used the outer lampholder sleeve can be
shifted upwards to cover the lamp base completely.
Assemble luminaire top.
Revamping Maintenance
Disconnect the electrical installation.
Open the luminaire and clean.
Use only solvent-free cleansers.
Change the lamp. Close the luminaire.
When cleaning please do not use high pressure cleaners.
Spares
LED lamp 3000K
Spare glass
Lampholder
LED lamp 3000K | 13 584 |
---|---|
Spare glass | 14 000 341 |
Lampholder | 63 000 355 |
BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com
www.bega.com