CANARM SD24-F1 Standard Exhaust Fans Instruction Manual
- June 9, 2024
- CANARM
Table of Contents
SD24-F1 Standard Exhaust Fans
Instruction Manual
STANDARD
EXHAUST FANS
operation Instructions and Parts manual
READ AND SAVE THESE INSTRUCTIONS
SD24-F1 Standard Exhaust Fans
WARRANTY
CANARM Ltd. warrants every new fan to be free of defects in material and
workmanship, to the extent that, within a period of one year from the date of
purchase CANARM Ltd. shall either repair or replace at CANARM’s option, any
unit or part thereof, returned freight prepaid, and found to be defective.
This warranty does not include any labour or transportation costs incidental
to the removal and reinstallation of the unit at the user’s premises.
Components repaired or replaced are warranted through the remainder of the
original warranty period only.
This warranty applies to the original purchaser-user only; it is null and void
in case of alteration, accident, abuse, neglect, and operation not in
accordance with instructions.
NOTICE: No warranty claims will be honored by CANARM Ltd. unless prior
authorization is obtained.
Standard Exhaust Fans
INSTRUCTION MANUAL FOR STANDARD EXHAUST FANS
Read Instructions complete before Installation & save for reference
Congratulations on the purchase of your quality built direct drive, wall
exhaust ventilation fan. All of these models use totally enclosed motors with
thermal over load protection. Variable speed motors are high efficiency
motors which save on electrical costs and can be run as a single speed motor.
The motors are mounted on heavy gauge welded steel rod motor mounts that have
a Bright Zinc finish. Fans come fully assembled and 100% of fans are tested
for proper operation before shipping.
These are general Instructions which cover our singled, variable and two
sped standard fans, as well as our singled sped explosion’s Proof models.
STANDARD FANS:
These models have a rugged, welded steel box housing with a powder coated
finish and aluminum or plastic exhaust louvers that are supported by long life
nylon bushings. The louvers open automatically when the fan starts up and
close when the fan stops
Fan Size | A | B | C | D (c/c) | E | N | Framing |
---|---|---|---|---|---|---|---|
8″ | 13 1/4″ | 11″ | 4″ | 12″ | 10 3/4″ | 2 | 11 X 11 |
10″ | 15 1/4″ | 11″ | 4″ | 14″ | 12 3/4″ | 2 | 13 X 13 |
12″ | 17 1/4″ | 17″ | 6″ | 16″ | 14 3/4″ | 3 | 15 X 15 |
14″ | 19 1/4″ | 17″ | 6″ | 18″ | 16 3/4″ | 3 | 17 X 17 |
16″ | 21 1/4″ | 17″ | 6″ | 20″ | 18 3/4″ | 4 | 19 X 19 |
18″ | 23 1/4″ | 15″ | 6″ | 22″ | 20 3/4″ | 4 | 21 X 21 |
20″ | 25 1/4″ | 18″ | 6″ | 24″ | 22 3/4″ | 5 | 23 X 23 |
24″ | 29 1/4″ | 18″ | 6″ | 28″ | 26 3/4″ | 5 | 27 X 27 |
30″ | 35 1/4″ | 19″ | 6″ | 34″ | 32 3/4″ | 16 | 33 X 33 |
36″ | 41 1/4″ | 18″ | 6″ | 40″ | 38 3/4″ | 20 | 39 X 39 |
42″ | 47 1/4″ | 18″ | 6 3/4″ | 46″ | 44 3/4″ | 24 | 45 X 45 |
48″ | 53 1/4″ | 19″ | 6 3/4″ | 52″ | 50 5/8″ | 26 | 51 X 51 |
EXPLOSION PROOF FANS:
Explosion proof fans are equipped with single speed explosion proof motors and
aluminum blades so sparks cannot occur if a metal object obstructs the blade
path. Explosion proof fans have the same quality welded steel box housing and
heavy gauge welded guard as the standard fans. These fans should be used to
ventilate hazardous areas. Locations are considered hazardous if the
atmosphere contains or may contain gas, vapor, or dust in explosive
quantities.
The motor ambient temperature Is not to exceed +40˚c or -25˚c unless the motor
nameplate specifically Permits another value. the following table Indicate
which hazardous classifications canard explosion’s Proof fans do and do not
meet.
Canard explosion proof fans do meet the following hazardous classifications.
class 1, division 1 (gases, vapors)
group c Acetaldehyde, cyclopropane, Dirichlet, Ethylene, isoprene
group d Acetone, acrylonitrile, ammonia, benzene, butane, ethylene dichloride,
gasoline, hexane, methane, methanol, naphtha, propane, propylene styrene,
toluene, vinyl, acetate, vinyl chloride, xylene class 2, division 1
(combustible dusts)
group f Carbon black, coke or coal dust group g Flour, starch or grandest|
Canard explosion proof fans do not meet the following hazardous
classifications.
class 1, division 1 (gases, vapors)
group a Acetylene
group b Butadiene, ethylene oxide, hydrogen, propylene oxides 2, division 1
(combustible dusts)
group e Aluminum, magnesium and other metal dusts with similar characteristics
---|---
INSTALLATION
Installation is fast and simple. A sturdy framed wall opening should be
prepared in advance to the size indicated for your fan in the charts above.
With lag bolts for wooden frames or nut, bolt and lock washers for steel
frames, secure the fan using the four mounting holes provided, one in each
corner of the fan.
ELECTRICAL CONNECTIONS
warning: be sure Power Is off at the electrical Panel before wiring.
warning: all electrical work should be Performed by a Qualified
electrician.
These fans are supplied with single, two or variable speed motors. Single and
two speed motors are 120V only. Variable speed motors are dual voltage. All
dual voltage motors are pre-wired at 240V in our factory. Rewire motor as per
motor nameplate if running fan at 120V. Please see the motor nameplate for
wiring diagram. Make electrical connections in motor connection box as per
the motor nameplate. Two speed fans require a two speed control or 3 position
toggle switch to change from high/ low/off. See wiring diagram with control
for 2 speed wiring instructions.
If your unit contains the Emhart Motor please follow these wiring
diagrams:
OPERATION
warning: variable sped fans should have the minimum sped set to open
louvers at least one Inch for Proper motor cooling and to Prevent motor
failure.
All fans are direct drive. Fans with variable speed motors can be operated as
an energy efficient single speed fan or in variable operation with the proper
controller. As mentioned above two speed fans require a two speed control or
3 position toggle switch to change from high speed to low and off.
warning: guarding should be used If fans are mounted lower than seven feet
(2 metres) off floor or ground level.
ACCESSORIES
Canard provides a complete line of manual and thermostatic controls. Canard also offers wall mount exhaust shutter kits, replacement shutter sets, and weather protection hoods.
MAINTENANCE
MOTORS ARE EQUIPPED WITH AUTOMATIC OVERLOAD PROTECTION AND MAY RESTART WITHOUT WARNING. ALWAYS DISCONNECT FROM POWER BEFORE ATTEMPTING SERVICE. Motor, blade and louvers should be kept clean of any buildup to prevent premature motor failure and to achieve proper performance. Automatic louvers should be kept operating freely. As with all mechanical equipment scheduled inspections should include checking that all hardware is secure and blade set screws are tight.
canard ltd.
2157 PARKEDALE AVE. PO BOX 367
BROCKVILLE, ONTARIO K6V 5V6
TELEPHONE: 613-342-5424
FAX: 1-800-263-4598
canard lee.
2555 RUE BERNARD LEFEBVRE
LAVAL, QUEBEC H7C 0A5
TELEPHONE: 450-665-2535
FAX: 450-665-0910
Arthur manufacturing facility
7686 CONCESSION 16, RR4
ARTHUR, ONTARIO N0G 1A0
TELEPHONE: 519-848-3910
FAX: 519-848-3948
SD_FANS_M_M0019 – 09/21/22