CANARM SD24-F1 Standard Exhaust Fans Instruction Manual

June 9, 2024
CANARM

CANARM logo SD24-F1 Standard Exhaust Fans
Instruction Manual

STANDARD
EXHAUST FANS
operation Instructions and Parts manual
READ AND SAVE THESE INSTRUCTIONS

SD24-F1 Standard Exhaust Fans

CANARM SD24 F1 Standard Exhaust Fans - fig

WARRANTY

CANARM Ltd. warrants every new fan to be free of defects in material and workmanship, to the extent that, within a period of one year from the date of purchase  CANARM Ltd. shall either repair or replace at CANARM’s option, any unit or part thereof, returned freight prepaid, and found to be defective.
This warranty does not include any labour or transportation costs incidental to the removal and reinstallation of the unit at the user’s premises.
Components repaired or replaced are warranted through the remainder of the original warranty period only.
This warranty applies to the original purchaser-user only; it is null and void in case of alteration, accident, abuse, neglect, and operation not in accordance with instructions.
NOTICE: No warranty claims will be honored by CANARM Ltd. unless prior authorization is obtained.

Standard Exhaust Fans

INSTRUCTION MANUAL FOR STANDARD EXHAUST FANS
Read Instructions complete before Installation & save for reference
Congratulations on the purchase of your quality built direct drive, wall exhaust ventilation fan. All of these models use totally enclosed motors with thermal over load  protection. Variable speed motors are high efficiency motors which save on electrical costs and can be run as a single speed motor. The motors are mounted on heavy gauge  welded steel rod motor mounts that have a Bright Zinc finish. Fans come fully assembled and 100% of fans are tested for proper operation before shipping.
These are general  Instructions which cover our singled, variable and two sped standard fans, as well as our singled sped explosion’s Proof models.

STANDARD FANS:
These models have a rugged, welded steel box housing with a powder coated finish and aluminum or plastic exhaust louvers that are supported by long life nylon bushings. The louvers open automatically when the fan starts up and close when the fan stopsCANARM SD24 F1 Standard Exhaust Fans -
fig1

Fan Size A B C D (c/c) E N Framing
8″ 13 1/4″ 11″ 4″ 12″ 10 3/4″ 2 11 X 11
10″ 15 1/4″ 11″ 4″ 14″ 12 3/4″ 2 13 X 13
12″ 17 1/4″ 17″ 6″ 16″ 14 3/4″ 3 15 X 15
14″ 19 1/4″ 17″ 6″ 18″ 16 3/4″ 3 17 X 17
16″ 21 1/4″ 17″ 6″ 20″ 18 3/4″ 4 19 X 19
18″ 23 1/4″ 15″ 6″ 22″ 20 3/4″ 4 21 X 21
20″ 25 1/4″ 18″ 6″ 24″ 22 3/4″ 5 23 X 23
24″ 29 1/4″ 18″ 6″ 28″ 26 3/4″ 5 27 X 27
30″ 35 1/4″ 19″ 6″ 34″ 32 3/4″ 16 33 X 33
36″ 41 1/4″ 18″ 6″ 40″ 38 3/4″ 20 39 X 39
42″ 47 1/4″ 18″ 6 3/4″ 46″ 44 3/4″ 24 45 X 45
48″ 53 1/4″ 19″ 6 3/4″ 52″ 50 5/8″ 26 51 X 51

EXPLOSION PROOF FANS:

Explosion proof fans are equipped with single speed explosion proof motors and aluminum blades so sparks cannot occur if a metal object obstructs the blade path.  Explosion proof fans have the same quality welded steel box housing and heavy gauge welded guard as the standard fans. These fans should be used to ventilate hazardous  areas. Locations are considered hazardous if the atmosphere contains or may contain gas, vapor, or dust in explosive quantities.
The motor ambient temperature Is not to exceed +40˚c or -25˚c unless the motor nameplate specifically Permits  another value. the following table Indicate which hazardous classifications canard explosion’s Proof fans do and do not meet.

Canard explosion proof fans do meet the following hazardous classifications.
class 1, division 1 (gases, vapors)
group c Acetaldehyde, cyclopropane, Dirichlet, Ethylene, isoprene
group d Acetone, acrylonitrile, ammonia, benzene, butane, ethylene dichloride, gasoline, hexane,  methane, methanol, naphtha, propane, propylene styrene, toluene, vinyl, acetate, vinyl chloride, xylene class 2, division 1 (combustible dusts)
group f Carbon black, coke or coal dust group g Flour, starch or grandest| Canard explosion proof fans do not meet the following hazardous classifications.
class 1, division 1 (gases, vapors)
group a Acetylene
group b Butadiene, ethylene oxide, hydrogen, propylene oxides 2, division 1 (combustible dusts)
group e Aluminum, magnesium and other metal dusts with similar characteristics
---|---

CANARM SD24 F1 Standard Exhaust Fans - Exhaust Fans

INSTALLATION

Installation is fast and simple. A sturdy framed wall opening should be prepared in advance to the size indicated for your fan in the charts above.
With lag bolts for wooden frames or nut, bolt and lock washers for steel frames, secure the fan using the four mounting holes provided, one in each corner of the fan.

ELECTRICAL CONNECTIONS

warning: be sure Power Is off at the electrical Panel before wiring.

warning: all electrical work should be Performed by a Qualified electrician.
These fans are supplied with single, two or variable speed motors. Single and two speed motors are 120V only. Variable speed motors are dual voltage. All dual voltage motors  are pre-wired at 240V in our factory. Rewire motor as per motor nameplate if running fan at 120V. Please see the motor nameplate for wiring diagram. Make  electrical connections in motor connection box as per the motor nameplate. Two speed fans require a two speed control or 3 position toggle switch to change from high/ low/off. See wiring diagram with control for 2 speed wiring instructions.
If your unit contains the Emhart Motor please follow these wiring diagrams:CANARM SD24 F1 Standard Exhaust Fans -
Motor

OPERATION

warning: variable sped fans should have the minimum sped set to open louvers at least one Inch for Proper motor cooling and to Prevent motor failure.
All fans are direct drive. Fans with variable speed motors can be operated as an energy efficient single speed fan or in variable operation with the proper controller. As  mentioned above two speed fans require a two speed control or 3 position toggle switch to change from high speed to low and off.
warning: guarding should be used If fans are mounted lower than seven feet (2 metres) off floor or ground level.

ACCESSORIES

Canard provides a complete line of manual and thermostatic controls. Canard also offers wall mount exhaust shutter kits, replacement shutter sets, and weather protection hoods.

MAINTENANCE

MOTORS ARE EQUIPPED WITH AUTOMATIC OVERLOAD PROTECTION AND MAY RESTART WITHOUT WARNING. ALWAYS DISCONNECT FROM POWER BEFORE ATTEMPTING SERVICE. Motor, blade and louvers should be kept clean of any buildup to prevent premature motor failure and to achieve proper performance. Automatic louvers should be kept operating freely. As with all mechanical equipment scheduled inspections should include checking that all hardware is secure and blade set screws are tight.

CANARM logo
canard ltd.
2157 PARKEDALE AVE. PO BOX 367
BROCKVILLE, ONTARIO K6V 5V6
TELEPHONE: 613-342-5424
FAX: 1-800-263-4598
canard lee.
2555 RUE BERNARD LEFEBVRE
LAVAL, QUEBEC H7C 0A5
TELEPHONE: 450-665-2535
FAX: 450-665-0910
Arthur manufacturing facility

7686 CONCESSION 16, RR4

ARTHUR, ONTARIO N0G 1A0
TELEPHONE: 519-848-3910
FAX: 519-848-3948
SD_FANS_M_M0019 – 09/21/22