General Information

Thank you for choosing a Petermann product.

Please read the user manual carefully before using the product for the first time!

The current understanding in modern occupational health and safety is that people in nursing professions
experience significant work-related physical strain. Back injuries are common. There are many situations in which a patient has to be transferred from a bed, a wheeled stretcher, ambulance stretcher, an X-Ray table or a wheelchair to a different stretcher or seat. The strain on the user and the patient / care- dependent can be reduced significantly through the use of sliding mats.

The use of transfer aids should be conditional upon the user having learned to use the equipment properly. The user has to decide for themselves what equipment is suitable to the patient’s situation and the intended sequence of movements.

The Lifting Mat is part of a product line which is used specifically to aid in the transfer of patients in home
care,hospitals and other health care facilities.

The product may only be used for the specified purpose and under the specified conditions.

The information in this user manual is for the patient who is being transferred and moved, as well as the user performing the transfer / position change.

Contact us if you require additional information or assistance using the Petermann product.

Product versions

Item no.: PM-4012 Lifting Mat with 4 grips
Item no. : PM-4016 Lifting Mat with 6 grips

Accessories

No accessories are available for this device.

Scope of delivery

Lifting  Mat User manual

If the product is used in accordance with the safety instructions, then the expected product service life is five years.

However, the effective service life may vary depending on the frequency and intensity of use and the number of washing and disinfection cycles.

Perform regular function checks on the product and be sure to observe the safety information (see item 2).

Safety information

WARNING indicates a potential danger which could lead to personal injury or material damage.

  • It is the responsibility of the organisation / the user to determine, on the basis of the circumstances
    (weight / health condition of the patient) and the capabilities of the user, whether several users may be required for the transfer and/or whether additional safety measures are required.

  • Never leave the patient unattended during the transfer process.

  • Observe the load handling regulations when performing patient lifting procedures.

  • Defective products may no longer be used.

  • Ensure that the transfers are performed by the users in a back-friendly manner.

  • Weight limits must be observed (200 kg).

  • Transfer products are subject to a natural ageing process. Inspect the equipment regularly to ensure proper functionality.

  • The use of non-standard cleaning agents or bleaching agents, alcohols, fabric softeners or other chemical laundry additives may lead to permanent deterioration of the product properties.

Symbols used

  • 60 Claundry
  • Do not bleach
  • Dry at low temperatures
  • Do not iren
  • Do not dry clean
  • Warning
  • Observe the user manual
  • Do not use fabric softener
  • max. load capacity see item 6
  • Manufacturer
  • Batch no./lot no..
  • Identification code
  • Conformity mark
  •   Item number
  • Medical device label

Function check

Transfer products are also subject to a natural ageing process. Inspect the equipment regularly and carefully, in particular before each use.

Visual inspection

Ensure that material, seams, handle loops and buckles are undamaged and in functional order.

Load test handles
Pull firmly on the handle loops – Check  material and seams

Load test buckles
Pull firmly on the closed buckle – Check buckle and seams

Sliding properties
Place the product on a firm surface Pull your hands over the product with pressure Good glide – easy gliding
Low glide: no gliding/moving pos

Defective products may no longer be used!

Using the product

Indication and fur the

Due to the wide range of possible applications, the indications cannot be tied to a specific clinical picture, since Lifting Mats are suitable for all applications involving people who require assistance.

  • Positioning in the bed of patients with severely restricted mobility.
  • Positioning in the bed of patients who are highly sensitive to pain.
  • Elevating/lifting patients at lower heights.
  • In case of leg fractures only the longer Lifting Mat (PM-4016) may be used for the transfers

This product may be reused.

Before reusing the product, be sure to perform a thorough function check (see item 2.2) as well as cleaning and disinfection of the product. (see item 5)

Contraindications

Contraindications cannot be tied to a specific clinical picture. Observe the safety information under item2.

  • In case of leg fractures only the longer Lifting Mat (PM-4016) may be used for the transfers

**Application risks

**

The product can be used in home care and other health care facilities as well as hospitals.

**Application illustration

**

Application

The Lifting Mat can be used to move a patient who is lying in bed towards the head of the bed and sideways.

Transfers from the bed to a shower stretcher and lifting a patient up from the floor are also possible.

Placement

  • Place the patient on their side.
  • Fold the Lifting Mat handles under the board.
  • Place the Lifting Mat against the patient’s back.
  • Place the patient on their back.
  • Pull the folded under handles out sideways.
  • The patient should be positioned in the centre of the Lifting Ma

Visit our website at www.pm-med.de or watch our comprehensive product videos on our YouTube channel.

Approved accessories, combination with other products

Peterman transfer aids are part of a comprehensive aid product range, which are effective and back friendl for the user and comfortable and supportive for the patients. Additional Peterman products may be used  according to the situation and clinical picture. Ask our experts. We are happy to

Product marking / CE

The Petermann Lifting Mat is a Class I Medical Device and meets the EU- Regulation 2017/745 of the European Parliament and Council dated 05.04.2017 for medical devices, hereinafter called MDR.

Petermann GmbH is certified in accordance with DIN EN ISO 13485 by TÜV Süd, Medical Devices – Quality management systems applicable to the design and development, production and distribution of aids for people of limited mobility

Cleaning, care and disinfection

Cleaning Desinfection (if necessary)
60° washing machine Recommended disinfectants for wipe disinfection:
  • Trionic® (DGHM/VAH approval, further information on request)
  • Mikrobac® Tissues*
  •  Mikrobac® forte
  • Bacillol® 30 Foam
  • Bacillol® 30 Tissues
  •  Bacillol® 30 Sensitive Tissues
  • Mikrobac® Virucidal Tissue*

Mild detergent
Do not use cleaning agents with bleaching ingredients or chemical laundry additives! Otherwise the product properties may deteriorate permanently.
Wash with similar colours only|

  • wipe with a cloth soaked in water after disinfection to avoid residues or layer build-up. Please always follow the manufacturer’s manuals for use when wiping disinfection

Recommended detergent for industrial washing machines: – – Maximo Liquid as singl
Low dryer temperatures (45° – 50° C)

Be sure to follow the care instructions on the label of each product as well as the manuals for use.

The inner reinforcing components must be removed!

Technical Data

Item n Materia Colour Load-bearing capacity
PM-4012 Polyamide, latexfrei red 200 kg
PM-4016 Polyamide, latexfrei red 200
PM-4012 Lifting Mat 1100 x 560 x 10 1240 g
PM-4016 Lifting Mat 1500 x 560 x 1 2100 g

The manufacturing of our products is subject to highest quality standards. Due to usual manufacturing variations published dimensions and further information concerning the condition of the product are defined as target production specifications. Deviations which might occur are monitored by professional quality management procedures and do not represent a reduction in performance of the respective product.

Warranty

  • The company Petermann warrants that the product is free from defects in material and workmanship.
  • The warranty period is 3 years. It does not cover defects attributable to abrasion, normal wear, improper use or improper cleaning.
  • The company Petermann is not liable for accidental or consequential injury or material damag

Disposal information

There are no specific disposal regulations for Lifting Mats, they can be disposed of in accordance with
applicable national and local regulations.

Petermann GmbH
Waldweg 3
D-91601 Dombühl
Phone: +49 (0) 9868-9339-0
Email: petermann@pm-med.de

Petermann GmbH
Waldweg 3
D-91601 Dombühl
Telefon: +49 (0) 9868-9339-0
E-Mail: petermann@pm-med.de

Company Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals