Ceiling and wall luminaire for indoor use
Bega 67 984 Ceiling and Wall Luminaires - fig 1

Instructions for use

Application
Ceiling and wall luminaire · indoor luminaire made of hand-blown opal glass, satin matt and metal housing, for all lighting tasks.
They are ideal for places where a soft and uniform lighting distribution is required. Luminaire with a high protection class.
Lamp
Luminaire with screw base E 27
Lamp output max. 75 W
This product contains light sources of energy
efficiency classes E, F
Supplied lamp
BEGA LED lamp 13548
LED 7 W · 805 lm · 2700 K dimmable
Supplied lamp
BEGA LED lamp 13586
LED 7 W · 805 lm · 3000 K dimmable
Luminaire efficiency: 61.5%
Detailed technical and lighting data for the lamps can be found in the data sheets on our website.

Product description

Luminaire made of aluminium alloy
Finish Colour white
Hand-blown opal glass, satin matt, with sliding-bolt closure 2 mounting holes ø 5.5 mm
Distance apart 65 x 112,5 mm
1 cable entry for mains supply cable up to ø 10.5 mm max. 3 x 1.5@
Connection terminal 2.5@
Earth conductor connection
Lampholder E 27
Safety class I
Protection class IP 44
Protected against granular foreign bodies
≥ 1 mm and splash water
– Safety mark
** – Conformity mark
Weight:** 1.1 kg

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the
luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Installation

Lead the mains supply cable through the cable entry into the luminaire housing.
For wall installation note position of application of luminaire »arrow down«.
Fix luminaire housing with enclosed or any other suitable fixing material on to the mounting surface.
It is imperative to use the enclosed gaskets.
Make earth conductor connection.
Push silicone sleeves over the lines and make electrical connection to the terminal.
Insert lamp.
Insert the opal glass into sliding bolt glass closure and turn clock-wise up to the stop.
Place glass to the luminaire housing and observe that the holding springbolts fit into the notches of the glass.
Turn the glass clockwise until it is locked.
Thus, you reach a safe and vibration-resistant holding of the glass.
To release the glass from the luminaire housing, turn it counter-clockwise.

Relamping · Maintenance

Disconnect from main supply.
Unscrew glass from luminaire housing by turning it counter-clockwise.
Clean glass and luminaire regularly with solvent-free cleansers from dirt.
Change the lamp.
Screw in glass by turning it clockwise beyond the stop.

Accessory · Trim rings

For this luminaire metal trim rings in 4 surfaces are optional available.
Trim rings are accessories and must be ordered separately.

Item Part. No
Colour white 13 054
Stainless steel 13 055
Chrome 13 056
Brass 13 057

Spares

Spare glass 11 002 874 .0R G
LED lamp 2700 K 13 548
LED lamp 3000 K 13 586
Lampholder 63 000 187
Reflector 76 000 678

BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden