BEGA 67 682.1 Wall Luminaire

Wall luminaire for indoor use

BEGA-67-682.1-Wall-Luminaire-FIG-1

Instructions for use

Application
Wall luminaire · indoor luminaire made of hand-blown opal glass, satin matt and metal housing. For all lighting tasks in interior applications. Luminaire with a high protection class.

Product description

  • Die-cast aluminium and aluminium housing, finish Colour white
  • Hand-blown opal glass, satin matt
  • Silicone gasket 2 mounting holes ø 5.5 mm
  • Distance apart 340 x 56 mm 2 cable entries for through-wiring for mains cable up to ø 10,5 mm max. 5 x 1.5@ Connection terminal 2.5@
  • Earth conductor connection 2-pole connecting terminal for digital control
  • LED power supply unit 220-240 V x 0/50-60 Hz
  • DC 176-264 V DALI-controllable
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect temperature-sensitive components
  • Safety class I
  • Protection class IP 44
  • Protected against granular foreign bodies ≥ 1 mm and splash water
  • Impact strength IK03
  • Protection against mechanical impacts < 0.35 joule r – Safety mark c  – Conformity mark
  • Weight: 1.7 kg

This product contains light sources of energy efficiency classes D

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 10.4 W
  • Luminaire connected wattage 12.5 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 45 °C

67 682.1 K27

  • Module designation 2x LED-0551/927
  • Colour temperature 2700 K
  • Colour rendering index CRI > 90
  • Module luminous flux 1540 lm
  • Luminaire luminous flux 1084 lm
  • Luminaire luminous efficiency 86,7 lm / W

67 682.1 K3

  • Module designation 2x LED-0551/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 1590 lm
  • Luminaire luminous flux 1120 lm
  • Luminaire luminous efficiency 89,6 lm / W

Installation

  • LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Loosen screw of the lateral cover and take off the glass from the luminaire housing.
  • Lead the mains supply cable through the cable entry into the luminaire housing.
  • Fix the luminaire housing with enclosed or any other suitable fixing material onto the mounting surface.
  • Make sure to use the gaskets supplied. Make earth conductor connection.
  • Push silicone sleeves over the lines and make electrical connection.
  • For digital control please use the connecting terminal DA, DA.
  • In case this terminal is not used the luminaire will be operated at full light output.
  • Position glass into the base plate and fix it with the screw and the cover.

Cleaning  Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.

Replacement of the LED module
The designation of the LED module is noted on a label in the luminaire. The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools. Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module. Inspect and, if necessary, replace the luminaire gaskets. Defective glass must be replaced. Close the luminaire.

Spares

  • Spare glass 11 002 798 .0R G
  • LED power supply unit DEV-0388/370
  • LED module 2700 K LED-0551/927
  • LED module 3000 K LED-0551/930
  • Gasket glass 81 000 277 .1
  • Gasket 83 001 249

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com