IMPORTANT SAFETY INSTRUCTION

  • WARNING
    Make certain power is OFF before starting installation or attempting any maintenance.

  • WARNING
    Risk of fire/electric shock. If not qualified, consult an electrician.

  • WARNING
    Risk of Electric Shock – Disconnect power at fuse or circuit breaker before installing or servicing.

  • WARNING
    Risk of Personal Injury – Fixture may become damaged and/or unstable if not installed properly.

    • Do not mount luminaire within 6” of a combustible surface.
    • Do not handle luminaire by the glass. Do not touch LEDs.
  • WARNING
    Risk of Burn – Disconnect power and allow fixture to cool before servicing.

    • Note: These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.
    • Note: This lighting fixture has been shipped complete with one of several mounting options. Please follow the installation instructions specific to the catalog part that you ordered.
    • Note: Care must be taken not to set lighting fixture down on optical lenses or lift the fixture in the lens area.
    • Note: Specifications and dimensions subject to change without notice.

IMPORTANT: Read carefully before installing fixture. Retain for future reference.

GENERAL

Upon receipt of the fixture, thoroughly inspect for any freight damage which should be brought to the attention of the delivery carrier. Compare the catalog description listed on the packing slip with the fixture label on the housing to assure you have received the correct material.

SAFETY

This fixture must be wired in accordance with the National Electrical Code and applicable local codes and ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedure under installation section.

APPLICATIONS

This lighting fixture is designed for outdoor lighting services, and should not be used in area of limited ventilation or inside high ambient temperature enclosures. It must be stored in a dry location prior to installation. Do not expose lighting fixture to rain, dust or other environmental conditions prior to installation and insertion of photo control or shorting cap (if so equipped). Do not install the fixture near combustible materials or locate next to airflow blocking surfaces within 6 inches. Best results will be obtained if installed and maintained according to the following recommendations.

INSTALLATION

Tools required
Allen Key (3/16”), Phillips screw driver, electrical wiring tools.

Applications

  • Minimum 90°C Supply Conductors when connections are made external to the unit
  • Rated for 40°C (104°F) ambient
  •  Suitable for wet location
  •  Wall mount luminaire only
  • Construction is suitable for down mount only
  •  Must be mounted above grade at minimum four feet or higher

Mounting (Figure 1.)

  1. Remove the mounting plate from the fixture by loosening the two set-screws.

  2. Remove the protective paper from the supplied pressure sensitive adhesive backed gasket.

  3. Align the gasket to the holes on the mounting plate and apply pressure to secure to the back of the mounting plate.

  4. Mount the gasket applied mounting plate to the junction box or wall with the gasket away from the luminaire and secure to structure. (Figure 1.)

  5. Slide the luminaire mounting bracket over the top lid of the mounting plate.

  6. Tighten the two set-screws to secure the luminaire to the mounting plate.

Wiring (Figure 2.)

  1. The application notes, included within the unit and instruction sheet indicate the proper minimum supply wire rating.
  2. Supply wiring is accessible within the unit when the LightSquare mounting plate is removed by unscrewing four screws.
  3.  The luminaire comes standard wired for universal 120-277V driver supplied (347V when ordered).
  4. Complete the connections per the diagram (Figure 2.) and the NEC or Canadian standards using approved methods and devices.

FCC Statement

Declaration of Conformity
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Warranties and Limitation of Liability
Please refer to www.cooperlighting.com/legal for our terms and conditions.

ABOUT COMPANY

  • Cooper Lighting Solutions
  • Canada Sales
    • 5925 McLaughlin Road
    • Mississauga, Ontario L5R 1B8
    • P: 905-501-3000
    • F: 905-501-3172
    • © 2021 Cooper Lighting Solutions
    • All Rights Reserved
    • Publication No. IB514021EN
  • Cooper Lighting Solutions is a registered trademark.All trademarks are property of their respective owners.
  • Product availability, specifications, and compliances are subject to change without notice

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

COOPER Lighting Solutions User Manuals

Related Manuals