AIRZONE MU AZ6 Electronic Central Card Acuazone User Manual

June 3, 2024
AIRZONE

AIRZONE-logo

AIRZONE MU AZ6 Electronic Central Card Acuazone

Enironmental policy

  • Never dispose of this equipment with household waste. Electrical and electronic products contain substances that can be harmful to the environment if not properly handled. The crossed-out waste bin symbol indicates separate collection of electrical devices, which must be separated from other urban waste. For correct environmental management, at the end of its useful life the equipment should be taken to the collection centers provided for this purpose.
  • The parts that make it up can be recycled. Therefore, please respect the regulations in force regarding environmental protection.
  • If you replace the equipment, the original equipment must be returned to your dealer or deposited at a specialized collection center.
  • Violations are subject to the penalties and measures stipulated in environmental protection law.

Airzone Interfaces

AIRZONE BLUEFACE ZERO

Screensaver

AIRZONE-MU-AZ6-Electronic-Central-Card-Acuazone-fig-1

Main screen

AIRZONE-MU-AZ6-Electronic-Central-Card-Acuazone-fig-2

  • Note: If the system has Webserver, weather information will also appear.
  • Note: The Indoor Air Quality (IAQ) is measured by the particle sensor in the return. Three air qualities will be differentiated according to the volume of suspended particles: Good, Medium and Low. Only available for CE6 Flexa 4.0 systems.
  • Note: Not available for RA6 RadianT systems.

HVAC control

On/Off. Pressing the icon turns the zone in which the thermostat is located on or off.
23.5° Set-point temperature. Using the – and + signs that appear when you press on the temperature, you can select the desired set-point temperature, in steps of 0.5°C.
The temperature range permitted in heating mode is: 15-30°C. In cooling mode: 18-30°C. These vary depending on the level of efficiency (Eco-Adapt) that has been selected on the master interface.
Efficiency indicator. Depending on the working temperature, the Blueface zero thermostat displays a range of colors based on the system’s level of efficiency:

  • Green: very efficient.
  • Yellow: efficient.
  • Orange: inefficient.
  • Red: very inefficient.

Eco-Adapt function
This sets your system’s level of energy efficiency and adapts the temperatures to progressively more efficient values, establishing limits according to the degree of energy savings selected:

  • Off. The temperature range is the range permitted by the system.
  • Manual. Sets the temperature limits in the zones according to those defined in the master thermostat.AIRZONE-MU-AZ6-Electronic-Central-Card-Acuazone-fig-5

User settings
Select language/country Change brightness

Information. This parameter offers information about:

  • Zone: firmware, zone, association, actuator or communications status.
  • System: firmware, settings and information on system and installation controllers.
  • Devices: indicates the elements connected to the system.
  • Webserver: settings, IP address and MAC.

Warnings.

Fan speed
The default setting is Automatic mode, imposing airflow based on the number of zones on demand. Depending on the type of installation, it will be possible to select the speed manually from the master thermostat.AIRZONE-MU-AZ6
-Electronic-Central-Card-Acuazone-fig-6

Zone navigation

AIRZONE-MU-AZ6-Electronic-Central-Card-Acuazone-fig-7

The “All the zones” option allows you to control all the zones at the same time, communicating the changes to all of them. Press the name of a zone to control it remotely from the thermostat. When the system detects a temperature error in a specific zone, the zone displays the error code instead of the room temperature (see Incidents section). Remote zone navigation icons:

  • Return to the zone navigation list.
  • Return to the main screen.

Operation mode
This is managed from the master thermostat, press to access the selection menu. The available modes are as follows:

Stop. The HVAC system remains shut down regardless of the status of the rest of the zones. In addition, all terminal elements (grilles, dampers, etc.) will be closed.
Cooling. In this operation mode, the system only operates with the AC unit in cooling mode when any of the zones associated to the system is generating demand (set-point temp. < room temp.).
Heating. In this operation mode, the system only operates with the AC unit in heating mode when any of the zones associated to the system is generating demand (set-point temp. > room temp.).
Ventilation. In this operation mode, the system only operates with the AC unit in ventilation mode when any of the zones associated to the system is ON.
*Dry. In this operation mode, the system only operates with the AC unit in dry mode, refreshing the environment and prioritizing the operation to reduce humidity, when any of the zones is generating demand (set-point temp. < room temp.).
Note:** This mode is ideal for days when humidity is high: it reduces the occurrence of water particles on the grilles.

Zone settings
Press on the icons to access the parameters:

  • Sleep mode. Sleep mode is an eco-timer for switching off the zone. The selectable values are:
  • Off. The timer is off.
  • 30. Activates the timer and after 30 minutes, the zone is switched off.
  • 60. Activates the timer. After 30 minutes, the zone changes its temperature by one degree and 60 minutes after activation, the zone switches off.
  • 90. Activates the timer. After 30 minutes, the zone changes its temperature by one degree. 60 minutes after activation, the zone changes its temperature by another degree. 90 minutes after activation, the zone switches off.
  • Anti-freezing. Prevents the room temperature in the zone from dropping below 12°C, even if the zone is off. (In Stop mode it will not be activated).
  • Lite settings. In this parameter, you can define the base set-point temperature for the zone where the Airzone Lite thermostat is installed. You can also configure the wired Lite thermostat to act as a wireless thermostat: after a few seconds (during which it indicates the status of the zone), it will switch off.

Note: To access the Lite settings parameter, from any Airzone Blueface zero thermostat you must access the zone controlled by your Lite thermostat using the Zone navigation option. Depending on your installation and the configuration of your system, you can manage the following parameters:

  • Grille angle. Allows you to define an inclination on the Airzone smart grilles in the zone for
  • cooling and heating modes. The options are 40°, 45°, 50° and 90° (90° by default).
  • Control stages. Allows you to select the element you wish to heat or cool the zone.
  • Air. Only the air stage works.
  • Radiant. Only the radiant stage works.
  • Combined. The system combines the use of the air and radiant stages to reach the comfort temperature quickly and efficiently. This is the default setting.
  • Adjust slats. Define the inclination type of the horizontal and vertical slats on the systems where this function is available.
  • Q-Adapt. Allows you to define the airflow control algorithm that best fits the duct installation. The options available are:
  • Maximum: the system operates at maximum speed regardless of the number of zones.
  • Power: the system operates at a higher speed than in Standard mode to ensure airflow is increased.
  • Standard: the system changes speed depending on the number of zones.
  • Silence: the system operates at a lower speed than in Standard mode to improve noise reduction.
  • Minimum: the system operates at minimum speed regardless of the number of zones.

Note: In case of having a 0-10 V gateway; the algorithm, in addition, will take into account the minimum and maximum voltage values set by your installer in this menu.

Purification. Use this option to select the purification operation mode:

  • Auto. Purification is activated when the system is in air demand and, in addition, the Indoor Air Quality (IAQ) measured by the particle sensor is not Good. The zone will automatically stop purification when the zone has had a Good IAQ measurement for more than 5 minutes.
  • On. Purification is always on whenever there is air demand.
  • Off. Purification is not activated.

AIRZONE BLUEFACE ZERO PARAMETERS

The available parameters may vary depending on your system or

installation. Identify your system from the Airzone Blueface Zero thermostat, access:AIRZONE-MU-AZ6-Electronic-Central-Card-Acuazone-
fig-20

AIRZONE THINK

ScreensaverAIRZONE-MU-AZ6-Electronic-Central-Card-Acuazone-
fig-21

Main screen
Access the main screen by pressing “Airzone” from the screensaver:AIRZONE-
MU-AZ6-Electronic-Central-Card-Acuazone-fig-22

  • Only in the case of a wireless Think thermostat
  • Communication frequency: 868 MHz Maximum radiated power: 0 dBm
    • Note: If the system has Webserver, weather information will also appear.
    • Note: The Indoor Air Quality (IAQ) is measured by the particle sensor. Three air qualities will be differentiated according to the volume of suspended particles: Good, Medium and Low. Only available for CE6 Flexa 4.0 systems.
    • Note: Not available for RA6 RadianT systems.

HVAC control

  • On/Off. Pressing the icon turns the zone in which the thermostat is located on or off.
    23° Set-point temperature. Select the set-point temperature using the control bar (by pressing or sliding). You can select the desired set-point temperature in steps of 0.5°C. Slide to set the temperature with a larger range. The temperature range permitted in heating mode is: 15-30°C. In cooling mode: 18-30°C. These vary depending on the level of efficiency (Eco-Adapt) that has been selected on the master interface.

Operation mode
This indicates the mode in which the system is working. If your Airzone Think thermostat is a master thermostat, access the settings menu to change the operation mode. The available modes are as follows:

  • Stop. The HVAC system remains shut down regardless of the status of the rest of the zones. In addition, all terminal elements (grilles, dampers, etc.) will be closed.
  • Cooling. In this operation mode, the system only operates with the AC unit in cooling mode when any of the zones associated to the system is generating demand (set-point temp. < room temp.).
  • Heating. In this operation mode, the system only operates with the AC unit in heating mode when any of the zones associated to the system is generating demand (set-point temp. > room temp.).
  • Ventilation. In this operation mode, the system only operates with the AC unit in ventilation mode when any of the zones associated to the system is ON.
  • *Dry.** In this operation mode, the system only operates with the AC unit in dry mode, refreshing the environment and prioritizing the operation to reduce humidity, when any of the zones is generating demand (set-point temp. < room temp.).

Note: This mode is ideal for days when humidity is high: it reduces the occurrence of water particles on the grilles.

Fan speed
If your Airzone Think thermostat is a master thermostat, access the settings menu to change the fan speed. The default setting is Automatic mode, imposing airflow based on the number of zones on demand. Depending on the type of installation, it will be possible to select the speed manually from the master thermostat.AIRZONE-MU-AZ6-Electronic-Central-Card-Acuazone-
fig-23

Settings menu

From this menu you can access the following options:

  • Mode. If your Airzone Think thermostat is a master thermostat, select the operation mode the system is using. (See Operation mode section).
  • Speed. If your Airzone Think thermostat is a master thermostat, select the fan speed the AC unit is using. (See Fan speed section).
  • Sleep mode. Sleep mode is an eco-timer for switching off the zone. The selectable values are:
    • Off. The timer is off.
    • 30. Activates the timer and after 30 minutes, the zone is switched off.
    • 60. Activates the timer. After 30 minutes, the zone changes its temperature by one degree and 60 minutes after activation, the zone switches off.
    • 90. Activates the timer. After 30 minutes, the zone changes its temperature by one degree. 60 minutes after activation, the zone changes its temperature by another degree. 90 minutes after activation, the zone switches off.

Zone navigation (Not available on 3.5.0 or later version). Access the different zones of your system to modify the set-point temperature, switch the zone on or off and view all the information about it.

Purification. Use this option to select the purification operation mode:

  • Auto. Purification is activated when the system is in air demand and, in addition, the Indoor Air Quality (IAQ) measured by the particle sensor is not Good. The zone will automatically stop purification when the zone has had a Good IAQ measurement for more than 5 minutes.
  • On. Purification is always on whenever there is air demand.
  • Off. Purification is not activated.

AIRZONE THINK PARAMETERS

AIRZONE-MU-AZ6-Electronic-Central-Card-Acuazone-fig-24

  • Not available in version 3.5.0 or higher.

AIRZONE LITE

AIRZONE-MU-AZ6-Electronic-Central-Card-Acuazone-fig-25

Note: To access the Lite settings parameter, from any Airzone Blueface zero thermostat you must access the zone controlled by your Lite thermostat using the Zone navigation option. (See Zone settings section).

Important: After 10 seconds of inactivity, the wireless Lite thermostat will turn off all its LEDs to save battery power. A first press on shows the zone status (On/Off, operation mode and temperature). After this first press you can change the desired parameter (On/Off or temperature).

Basic functions

  • On/Off. Pressing the icon turns the zone in which the thermostat is located on or off. This button also indicates the system’s operation mode. It has a range of colors:
    • Purple: the system is shut down; the operation mode is Stop.
    • Red: the operation mode is Heating.
    • Blue: the operation mode is Cooling.
    • Green: comfort; the set-point temperature has been reached.

If the button shows a steady light, the controller is switched on. If the button is blinking, the controller is off. The button remains steady for 10 seconds to show its status, and then it turns off.

23° Set-point temperature. Using the buttons you can raise or lower the set-point temperature by up to 3°C (in steps of 1°C) with regard to the base set-point temperature defined in Lite settings parameter of the Blueface zero thermostat. (See Zone settings section). The LED lights indicate the set-point temperature. In the event that the temperature limit is exceeded, the temperature adjustment icons will flash, indicating that you have reached the limit.

CHANGE OF BATTERY

  • When the low battery icon appears on the display, the battery must be replaced. Note: In the case of wireless Lite thermostats, a “Lite low battery” warning message will appear on Blueface zero thermostats.
    To replace the battery, separate the thermostat from its base and replace the battery (CR2450).AIRZONE-MU-AZ6-Electronic-Central-Card-Acuazone-
fig-28

Important: The use of batteries from leading brands is recommended, similar to those provided. A battery of lesser quality may have a reduced life. Remember to place the old battery in an appropriate recycling bin.

Note: Remember to remove the anti-vandalism system (if installed) before removing the thermostat from the wall.

Incidents

In the case of Airzone Blueface zero and Think thermostats, a warning will appear on the screen. Depending on the system, devices and functionalities available, the following warnings may appear:

WARNINGS

  • Anti-freezing. This is displayed if the function is enabled.
  • Active window. Indicates that the air conditioning has been suspended in the zone due to an open window. Only available in systems that have enabled the control of windows.
  • DHW. Domestic hot water activated. If your system integrates DHW management control in its production unit and this is activated, this message will appear on your Blueface zero and the air conditioning in that zone will be suspended.
  • Low battery. Low battery warning.
  • Occupancy. It indicates no occupancy has been detected in the zone for the last 5 minutes. Therefore, the Sleep mode is activated (the zone will switch off after 90 minutes). Only available for systems with occupancy control.
  • Dew. This warning indicates there is a risk of condensation and the zone where the thermostat is located has been turned off, turning on the dehumidifier (if it is installed) and activating the
  • On/Off relay of the main control board. Only available for systems with radiant stage in cooling mode.
  • Active dew protection. It indicates there is a risk of condensation in the radiant stage and the air stage has been activated to avoid its creation.
  • Low battery Lite (Blueface zero only). Low battery warning. You will know the zone the warning comes from by pressing on the icon in the main screen.
  • Dew Lite (Blueface zero only). It indicates there is a risk of condensation and the zone where the Lite thermostat is located has been turned off. Press the icon in the main screen to know which zone is affected.
  • Dew protection Lite (Blueface zero only). It indicates there is a risk of condensation in the radiant stage and the air stage has been activated to avoid its creation in zone where the Lite thermostat is.
  • Preparing. This warning indicates that the heating/cooling battery is outside the temperature limits configured, and therefore ventilation will be deactivated until the working temperature required to satisfy demand is reached.
  • Low valve battery. Low battery warning for valve.
  • NTC2 alarm. Measurement error in the temperature probe
  • Filter maintenance. This indicates that filter maintenance should be performed.

ERRORS

In the case of any of the following errors, please contact your installer:

Communication errors

  • 1. Thermostat – Main control board / Zone Module
  • 2. Main control board – Zone Module
  • 8. Lite thermostat – Main control board
  • 9. Gateway – Airzone system
  • 10. BACnet gateway – Main control board
  • 11. Gateway – Indoor unit
  • 12. Webserver – Airzone system
  • 13. Control module of radiant elements – Main control board
  • 14. Expansion module – Main control board
  • 15. Consumption meter – Main control board
  • 17. Lutron gateway – Main control board
  • 18. Dehumidifier module – Main control board
  • 19. Alarm jumper error – Main control board
  • C-02. Production control board – Main control board
  • C-09. Air to water gateway – Production control board
  • C-11. Air to water gateway – Air to water unit
  • V01. AZX6CM1VALR Module – Main control board
  • V02. AZX6CM1VALR Module – AZX6AC1VALR Head
  • AC unit error. Anomaly in the AC unit

Purification errors

  • IAQ1. Loss of communication between the main control board and the ionization processor
  • IAQ2. Loss of communication between the particle sensor and the main control board
  • IAQ3. Zone module with ionization not connected
  • IAQ4. Actuator connected directly without ionizer

Other errors

  • 3. Motorized element not connected to the actuator output
  • 4. Unusual behavior of the motorized element
  • 5. Open circuit in the temperature probe
  • 6. Short circuit in temperature probe
  • 16. Measuring error in consumption meter
  • F05-H. Heat battery temperature sensor is opened
  • F05-C. The cold battery temperature sensor is opened
  • F06-H. The heat battery temperature sensor is short-circuited
  • F06-C. The cold battery temperature sensor is short-circuited
  • F0506-HC. Heat or cold battery temperature sensor is opened or short-circuited
  • R05. The control module of the radiant elements temperature sensor is opened
  • R06. The control module of the radiant elements temperature sensor is short-circuited

Airzone Lite errors

  • In the case of Airzone Lite thermostats, if the On/Off icon blinks rapidly in red, it means communication with the main control board has been lost. On Acuazone (DI6) systems, this means loss of communication between the main control board and de zone module.
  • Only in Acuazone (DI6) systems, if the On/Off icon  blinks rapidly in purple means loss of communication with the zone module.
  • airzonecontrol.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals