- Never dispose of this equipment with household waste. Electrical and electronic products contain substances that can be harmful to the environment if not properly handled. The crossed-out waste bin symbol indicates separate collection of electrical devices, which must be separated from other urban waste. For correct environmental management, at the end of its useful life the equipment should be taken to the collection centers provided for this purpose.
- The parts that make it up can be recycled. Therefore, please respect the regulations in force regarding environmental protection.
- If you replace the equipment, the original equipment must be returned to your dealer or deposited at a specialized collection center.
- Violations are subject to the penalties and measures stipulated in environmental protection law
Naidoo Pro Control Wi-Fi by Arizona
Device for remote management and integration of units via Cloud services.
Control via the
“Arizona Cloud” app (available for iOS and Android). Wireless network
connection via Wi-Fi.
Power supplied by external source. Functionalities:
- Control of the different AC unit parameters.
- Communication via Wi-Fi Dual (2.4/5 GHz).
- Possibility of integration via Local API and Cloud API.
- Detection of errors during communication.
- Time scheduling of temperature and operation mode.
- Multi-user and multi-session.
- Port for integration via Modbus protocol or thermostat connection.
- Automatic mode change.
- Temperature limits for hot and cold.
- On/Off input
For more information about our products, visit airzonecontrol.com
DEVICE ELEMENTS
1Both the shape of the terminal on the Naidoo Pro device and the shape of the
cable may vary
depending on the compatible manufacturer.
RS-485 port
RS485 port for establishing Modbus communication with the device. The device
will work as a Modbus secondary.
Connection to the indoor unit
This terminal allows the device to communicate with the indoor air to water unit or the thermostat via the connection cable, allowing management of the following parameters:
- On/Off
- Operation mode
- Set-point temperature
As well as reading of room temperature reading and errors in the unit.
Note : Both the shape of the terminal on the Naidoo Pro device and the
shape of the cable may
vary depending on the compatible manufacturer
Factory reset
This button allows you to restore the device to factory settings by pressing
it continuously for
more than 10 seconds.
Digital input
Voltage free input. It can be used as a window contact, occupancy or similar
to turn the AC unit
on/off if the input changes value.
By default it will be disabled and configured as “normally open.”
Note : It is recommended that the wiring of the digital inputs be routed
through a separate
conduit.
Reset of the device
Allows you to reset the device without removing any previously set configuration parameters.
Power supply input
12 Vdc input that enables providing power to the Aidoo Pro device.
The 230 Vac – 12 Vdc power supply is supplied with the device.
Relay output (12 V) – Auxiliary heat
The relay activation logic depends on whether the air to water unit is
configured to work with
supply water temperature or room temperature. No additional configuration is
required in the
Aidoo
Aerothermal LWT mode
Circuit status| Relay
Circuit 1 y Circuit 2 OFF| OFF
Circuit 1 and/or Circuit 2 ON| ON
Circuit 1 and/or Circuit 2 on demand| ON
DHW ON| OFF
DHW OFF| OFF
Circuit 1 y Circuit 2 OFF| OFF
Circuit 1 and/or Circuit 2 ON| OFF
Circuit 1 and/or Circuit 2 on demand| ON
DHW ON| OFF
DHW OFF| OFF
Aidoo Pro air to water units can work with up to 2 zones and DHW depending on
the
characteristics of each air to water unit. If there is more than one zone,
they must all have the
same working settings.
Diagnostic LEDs
Meaning
| Connecting to a Wi-Fi network| Blinking| Green
Connected to a Wi-Fi network| Steady
Connected to the server| Steady| Blue
Not configured| Off| –
| Cloud Communications| Blinking| Red
| Microprocessor activity| Blinking| Green
| Power supply| Steady| Red
| Transmission of data to the indoor unit| Blinking| Red
| Reception of data from the indoor unit| Blinking| Green
Configuration of Naidoo Pro Accessories
AIDOO PRO FANCOIL – AIDOO PRO AEROTERMIA EQUIPMENTS
Perform the connection and configuration of the elements according to their
technical
specifications:
- AZAI6WSPFAN – Naidoo Pro Fancily
- AZAI6WSPXXX – Naidoo Pro for aerothermal equipment
Continue with the following steps to complete the solution.
Connection
Connect the INT port of the Naidoo Pro Fancily to the RS485 port of the Naidoo Pro.
Configuration
Open the Arizona Cloud application. In the sidebar menu, tap on Airfoils to
access advanced settings. Tap on the Bluetooth icon to search for devices and
select the one you want to configure.
Tap on Integrations and select the output port with Naidoo Pro Aerothermal.
Operation
Mode | Zone | Water production |
---|---|---|
Cool/Heat | On | On |
Cool/Heat | Comfort | Off |
Off | Off |
Advanced settings
To perform advanced configuration of the device, download the Arizona Cloud
app.
To access the advanced settings follow the steps described in the Arizona
Cloud support section.
AIRZONE CLOUD
Information
Alias. Allows you to assign an alias to identify each device.
Name. Name of the device.
MAC. MAC address of the device.
Version. Displays the webserver version of the device.
Wi-Fi. Network linked to the device.
IP address. Displays the IP address of the device.
Integration. Integrations available through the webserver. Allows you to
make the following
configurations depending on the integration selected:
Local
- Local API. Enables the option of integration with third parties via Local API.
- MDNS. Enables the MDNS service for device discovery within a local network.
Integration port:
- Modbus RS485. Edition of the Modbus ID and selection of communication speed.
Indoor unit “. Displays the following information for the indoor unit: manufacturer, thermostat units (configurable in °C or °F), zone temperature and return temperature. * Not available in Bluetooth configuration.
Airfoils settings in Naidoo PRO Aerothermal
Auto Mode (dual setpoint) **. Allows you to configure changing from automatic mode based on the setpoints defined for the cooling and heating mode. The configurable parameters are:
-
Setpoint differential. Establishes the minimum differential between cooling mode and
heating mode setpoints (by default 1 ºC / 2 ºF). -
Mode switching protection (min). Allows you to define the minimum operating time
before allowing a change of mode, by default 30 min.
Available only in air to water units that have Auto mode and that are
configured to work
with room temperature (TH).
Limits . By default it is disabled. Once it is enabled, it allows you
to set the maximum
temperature for heating mode and the minimum temperature for cooling mode.
Available only if the air to water unit is configured to work with room
temperature (TH).
Note : When temperature limits are enabled it will not be possible to use Auto mode.
Digital input *. Allows you to activate or deactivate this function and change:
-
Settings. Allows you to set the input as normally open or normally closed.
a. Activation by state : the state is persistent, if the input is activated the machine will be forced off until it changes state.
b. Activation by edge : the status is punctual, only the on/off is sent when the opening
or closing condition is met for the first time. -
Time to turn off (minutes). Displays a drop-down for selecting the time (in minutes)
that you want to elapse before turning off the equipment after receiving the signal. If
disabled, the equipment will automatically turn off after receiving the signal. -
Time to turn on (minutes). Allows you to select the time (in minutes) that must elapse with the signal deactivated before the equipment turns on again. This setting only turns on the equipment if it has previously been turned off. If it is disabled, the equipment must be switched on again manually
-
In air to water units with 2 water circuits, the digital input only affects to circuit 1.
Operation of the device
FUNCTIONALITIES
Operation modes
The manufacturer’s units can operate in both room temperature mode (TH) and in
water
supply temperature mode (LWT).
Room temperature mode is not currently functional in Arizona systems, and the
unit must
always be previously configured to function only in water supply mode (LWT).
The Naidoo device will be able to regulate the temperature in two circuits in
water supply
mode.
DHW control
The manufacturer’s units allow you to manage domestic hot water (DHW)
production status
control.
The “Powerful” function can be activated in DHW production status control,
which forces the
DHW to reach a temperature that has been preset in the configuration of the
unit. If DHW is
turned off, it will not be possible to activate this parameter
Status modes
The unit status can be selected from the Arizonan device, enabling on/off
control of the unit,
after having performed the necessary configuration and wiring. The unit status
can be controlled in both water supply mode and in domestic hot water
production mode (DHW).
The selectable status mode values are Cooling mode, Heating mode and Auto
mode. If the
unit is operating in Auto mode, its operation will depend on the outdoor
temperature and the
thermostat room temperature.
Set-point temperature
The unit temperature will depend on the operation mode:
-
The unit must be previously configured to function in LWT mode, so the water supply
temperature at which the unit is to operate must be selected. -
The DHW temperature can be selected within the ranges set by the unit’s own main
thermostat.
The temperature limits can be obtained via protocol for LWT mode and for DHW
production
status control, and they depend on the unit model.WW
PRIOR MANUFACTURER CONFIGURATION
The unit must be configured from the installer menu in order to function correctly:
-
Set the indoor unit address to address 1:
- Go to menu “17. HMI ADDRESS SET”.
- Set the parameters to the following values:
17.1 HMI SET = MASTER
17.2 HMI ADDRESS FOR BMS = 1
-
Set the unit to water supply mode (LWT):
-
Go to menu “5. TEMP. TYPE SETTING”.
-
Set the parameters to the following values
5.1 WATER FLOW TEMP = YES
5.2 ROOM TEMP = NON
5.3 DOUBLE ZONE = (NON for 1 circuit, YES for 2 circuits) -
Go to menu “6. ROOM THERMOSTAT”.
-
Set the parameters to the following values:
6.1 ROOM THERMOSTAT = NON
-
Note : Changes must be saved before exiting the menu.
Compatibilities Tool
HOW TO KNOW IF MY AC UNIT IS COMPATIBLE WITH AIRZONE
Visit airzonecontrol.com, then go to the “Control
solutions” menu and select Naidoo Pro
Once selected, click on “Consult compatibility”:
Select the brand and then the model of your indoor unit:
The compatibility list with the selected unit will appear. If your
manufacturer or indoor AC unit
does not appear in the list, do not hesitate to contact us.