Westinghouse iGen2200 Inverter Generator Installation Guide

June 3, 2024
Westinghouse

Westinghouse Logo HIGH ALTITUDE KIT:
INSTALLATION GUIDEWestinghouse iGen2200 Inverter Generator -
Fig iGen2200 iGen2500
Works with 79cc and 98cc size Westinghouse Inverters
High Altitude Kit: Installation Guide Part A

iGen2200 Inverter Generator

This will show you how to install an altitude kit for operating your Westinghouse inverter generator at altitudes over 2000 feet.
Please reference Part A of this guide for instructions on the iGen2200 and iGen2500 models. If you have an iGen2500 manufactured before 3/2020 you will reference the instructions for the iGen2200.
Part B will be used for any iGen2500 manufactured after 03/2020 this can be confirmed by the serial number on your unit.

  1. Confirm the altitude you’ll be operating the generator and select the right carburetor jet for your application.

  2. To perform this installation, you’ll need a Phillips head screwdriver, a flat head screwdriver, a pair of needle nose pliers, a socket wrench, an 8mm socket, and a 10mm socket.

  3. Place the generator on a flat surface in a well ventilated area. First step is to make sure your generator is in the off position.Westinghouse iGen2200 Inverter Generator - Fig 3

  4. Next, you will use the carburetor drain hose to drain the gas out of the fuel tank.Westinghouse iGen2200 Inverter Generator - Fig 3

  5. Remove the 2 screws that secure the engine maintenance panel to the frame. Keep track of the screws and bolts as you disassemble the generator housing.Westinghouse iGen2200 Inverter Generator - Fig 5

  6. Slide off the spark plug access cover, and push on the maintenance panel to remove it.Westinghouse iGen2200 Inverter Generator - Fig 6

  7. Locate the clear plastic hose from the float that is exiting out the bottom of the generator, and place a gasoline safe container under it to catch the drained fuel.Westinghouse iGen2200 Inverter Generator - Fig 6

  8. Loosen the float bowl drain screw until fuel is seen draining from the float bowl. Allow any fuel to drain, then tighten the float bowl drain screw.Westinghouse iGen2200 Inverter Generator - Fig 8

  9. Continue with the removal of the generator cover. Remove the 3 bolts at the bottom of the engine access panel and the single bolt near the front air vents.Westinghouse iGen2200 Inverter Generator - Fig 9

  10. Remove the 3 screws at the top of the housing.Westinghouse iGen2200 Inverter Generator - Fig 8

  11. Remove the 2 screws at the top of the control panel and the 2 screws under the control panel.Westinghouse iGen2200 Inverter Generator - Fig 10

  12. a. Remove the rubber seal in the center of the engine control knob.
    b. Remove the screw.
    c. And remove the knob.Westinghouse iGen2200 Inverter Generator - Fig
11

  13. Pull the front panel off, leaving the wires behind the control panel attached. Using a pair of needle nose pliers, remove the clip located under the rubber fuel collector.Westinghouse iGen2200 Inverter Generator - Fig 12

  14. Remove the 6 screws that hold the muffler to the generator and remove the muffler.Westinghouse iGen2200 Inverter Generator - Fig 13

  15. Remove the 2 screws on the opposite side of the handle.Westinghouse iGen2200 Inverter Generator - Fig 14

  16. Finally remove the housing to gain access to the carburetor. Pull the spark plug wire off the spark plug.Westinghouse iGen2200 Inverter Generator - Fig 15

  17. Pull the breather tube off the carburetor.Westinghouse iGen2200 Inverter Generator - Fig 16

  18. Remove the screw in middle of the air cleaner and remove the foam filter.Westinghouse iGen2200 Inverter Generator - Fig 16

  19. Remove the bolt inside the air cleaner.Westinghouse iGen2200 Inverter Generator - Fig 18

  20. Remove the bolt on the right side that secures it to the engine mount.Westinghouse iGen2200 Inverter Generator - Fig 18

  21. Remove the 2 nuts that secure the air cleaner to the carburetor.Westinghouse iGen2200 Inverter Generator - Fig 20

  22. Remove the air cleaner assembly.Westinghouse iGen2200 Inverter Generator - Fig 21

  23. Remove the bolt from the bottom of the carburetor float bowl. There may be some leftover fuel in the carburetor so have a rag handy to clean any spills.Westinghouse iGen2200 Inverter Generator - Fig 20

  24. Remove the old jet, and install the new jet into the carburetor. As mentioned earlier, make sure you’re installing the proper jet for your model of generator and for the altitude. After you install the new jet, don’t throw away the old one.Westinghouse iGen2200 Inverter Generator - Fig 20

  25. If they are damaged, replace the o-ring where the bowl meets the carburetor, and the bolt seal on the bottom of the carburetor, with the parts supplied in the kit. Re-bolt the bowl onto the bottom of the carburetor.Westinghouse iGen2200 Inverter Generator - Fig 24

  26. To reassemble the generator, replace all the parts in the reverse order that they were removed. Time to check the installation. Move the generator to a wellventilated location, start the generator, and make sure it runs properly.

High Altitude Kit: Installation Guide Part B

Westinghouse iGen2200 Inverter Generator - Fig 24

  1. Part B will be used for iGen2500 manufactured after 03/2020 this can be confirmed by the serial number on your unit.Westinghouse iGen2200 Inverter Generator - Fig 24

  2. Confirm the altitude you’ll be operating the generator and select the right carburetor jet for your application.Westinghouse iGen2200 Inverter Generator - Fig 24

  3. To perform this installation, you’ll need a Phillips head screwdriver, a standard sized flathead screwdriver, a small 1/8in by 3in flat head screwdriver, a pair of needle nose pliers, a socket wrench, an 8mm socket, and a 10mm socket.Westinghouse iGen2200 Inverter Generator - Fig 24

  4. Place the generator on a flat surface in a well ventilated area. First step is to make sure your generator is in the off position.Westinghouse iGen2200 Inverter Generator - Fig 29

  5. Next, you will use the carburetor drain hose to drain the gas out of the fuel tank.Westinghouse iGen2200 Inverter Generator - Fig 29

  6. Remove the 2 screws that secure the engine maintenance panel to the frame. Keep track of the screws and bolts as you disassemble the generator housing.Westinghouse iGen2200 Inverter Generator - Fig 29

  7. Slide off the spark plug access cover, and push on the maintenance panel to remove it.Westinghouse iGen2200 Inverter Generator - Fig 29

  8. Locate the clear plastic hose from the float that is exiting out the bottom of the generator, and place a gasoline safe container under it to catch the drained fuel.Westinghouse iGen2200 Inverter Generator - Fig 29

  9. Loosen the float bowl drain screw until fuel is seen draining from the float bowl. Allow any fuel to drain, then tighten the float bowl drain screw. Westinghouse iGen2200 Inverter Generator - Fig 29

  10. Continue with the removal of the generator cover. Remove the 3 bolts at the bottom of the engine access panel and the single bolt near the front air vents.Westinghouse iGen2200 Inverter Generator - Fig 35

  11. Remove the 3 screws at the top of the housing.Westinghouse iGen2200 Inverter Generator - Fig 35

  12. Remove the 2 screws at the top of the control panel and the 2 screws under the control panel.Westinghouse iGen2200 Inverter Generator - Fig 37

  13. a. Remove the rubber seal in the center of the engine control knob.
    b. Remove the screw.
    c. And remove the knob.Westinghouse iGen2200 Inverter Generator - Fig
37

  14. Pull the front panel off, leaving the wires behind the control panel attached.Westinghouse iGen2200 Inverter Generator - Fig 39

  15. Using a pair of needle nose pliers, remove the clip located under the rubber fuel collector.Westinghouse iGen2200 Inverter Generator - Fig 40

  16. Remove the 6 screws that hold the muffler to the generator and remove the muffler.Westinghouse iGen2200 Inverter Generator - Fig 41

  17. Remove the 2 screws on the opposite side of the handle.Westinghouse iGen2200 Inverter Generator - Fig 42

  18. Finally remove the housing to gain access to the carburetor.Westinghouse iGen2200 Inverter Generator - Fig 42

  19. Pull the spark plug wire off the spark plug.Westinghouse iGen2200 Inverter Generator - Fig 42

  20. Pull the breather tube off the carburetor.Westinghouse iGen2200 Inverter Generator - Fig 45

  21. Unclip and pull off the breather tube connected to muffler.Westinghouse iGen2200 Inverter Generator - Fig 45

  22. Slide off the black carbon canister and set it aside.Westinghouse iGen2200 Inverter Generator - Fig 47

  23. Remove bolt holding the carbon canister bracket and pull the bracket off.Westinghouse iGen2200 Inverter Generator - Fig 48

  24. Remove the bolt on the right side of the air cleaner box that secures it to the engine mount.Westinghouse iGen2200 Inverter Generator - Fig 49

  25. Remove the screw in middle of the air cleaner and remove the foam filter.Westinghouse iGen2200 Inverter Generator - Fig 50

  26. Remove the bolt inside the air cleaner.Westinghouse iGen2200 Inverter Generator - Fig 51

  27. Remove the 2 nuts that secure the air cleaner to the carburetor.Westinghouse iGen2200 Inverter Generator - Fig 52

  28. Remove the air cleaner assembly. Be sure the paper gasket between the air filter and carburetor is not damaged.Westinghouse iGen2200 Inverter Generator - Fig 53

  29. Remove the bolt from the bottom of the carburetor float bowl. There may be some leftover fuel in the carburetor so have a rag handy to clean any spills. Westinghouse iGen2200 Inverter Generator - Fig 54

  30. Use the small flathead screwdriver to carefully remove the jet. Make sure the main nozzle stays in the carburetor. If it falls out, replace it in the correct orientation.Westinghouse iGen2200 Inverter Generator - Fig 55

  31. Install the new jet into the carburetor. As mentioned earlier, make sure you’re installing the correct jet for your model of generator and for the altitude. After you install the new jet, don’t throw away the old one.Westinghouse iGen2200 Inverter Generator - Fig 57

  32. If they are damaged, replace the o-ring where the bowl meets the carburetor, and the bolt seal on the bottom of the carburetor, with the parts supplied in the kit. Re-bolt the bowl onto the bottom of the carburetor.Westinghouse iGen2200 Inverter Generator - Fig 57

  33. Reassemble the generator in reverse order it was taken apart. Time to check the installation. Move the generator to a well-ventilated location, start the generator, and make sure it runs properly.