PROLED IP20 Flex Lighting Strip User Manual

June 5, 2024
PROLED

PROLED -logo FLEX STRIP IP20 / IP53 / IP68

PROLED IP20 Flex Lighting Strip-

User manual

Preface

Thanks for choosing the PROLED FLEX STRIP. Before installation and use, we strongly recommend you to read this manual carefully. If the Flex Strip has been damaged during transport, please report this to your supplier immediately. Please don’t take any action without contacting your supplier first.

Limited Warranty

In case of quality problems we provide free repair or replacement from the day of purchase, if this product has been used properly in accordance with the user’s manual, except in the following cases:

  1. Any defects caused by the wrong operation.
  2. Any damages caused by unauthorized removal, maintenance, modifying, incorrect connection, and replacement of chips.
  3. Any damages due to transportation, vibration, etc. after purchase.
  4. Any damages caused by earthquake, fire, lightning, pollution, and abnormal voltage.
  5. Any damages caused by negligence, inappropriate storing at high temperatures and humidity, or near harmful chemicals.
  6. Product has been updated

Safety Warnings

  1. Please don’t install this Flex Strip during thunderstorms, or intense magnetic or high-voltage electrical fields. Take care about correct connections to minimize the risk of damage to components or short circuits.
  2. Always be sure to mount this unit in an area with proper ventilation to avoid overheating.
  3. Check if the power supply fulfills the voltage and power requirements of the Flex Strip as well as the polarity.
  4. Make all connections only in powerless conditions and make sure that no short circuit is existing before switching on the Flex Strip.
    Please contact your local dealer for updates.

Product description

PROLED FLEX STRIP allows making different types of illumination. It can be used for the main illumination, background illumination, ambient illumination, etc. as well as inside or outside, or even underwater.

Cautions

Please follow below information using Flex Strips.

PROLED IP20 Flex Lighting Strip-fig1| PROLED IP20 Flex Lighting Strip-fig2
---|---
Do not bend sharply| Do not cover during working
PROLED IP20 Flex Lighting Strip-fig3| PROLED IP20 Flex Lighting Strip-fig4
Do not bend horizontally| Do not connect to a mains supply
PROLED IP20 Flex Lighting Strip-fig5| Do not expose to pressure

Safety cautions

  • Installation only according to local specifications
  • Installation only by professional staff
  • Use only Class 2 power supplies
  • Power supply must have the correct voltage. Voltage must correspond to voltage listed on Flex Strip
  • Use only cables which are specified for more than 80°C
  • Use the correct dimension of cables. Wrong cables can lead to overheating and eventually result in fire. Cable must be approved for the existing voltage and current
  • Use the Flex Strip only at an ambient temperature of -10 – 45°C
  • Do not stick IP20 & IP53 Flex Strips on conductive surfaces

Installation place

  1. Do not install the Flex Strip in an overheated ambient, for example near a radiator, or in a bad cooling surrounding.

  2. If the installation is in a high humidity surrounding, please use, suitable for the application, Flex Strip IP53 or
    IP68.

  3. Do not use the Flex Strip in an aggressive surrounding, for example containing sulfur, chloride, Brom, etc.
    a. Gas vapor can diffuse through the silicon cover and react with the LED surface. Due to this, the light output will be significantly lower and a temperature shift can’t be avoided. Furthermore, the resistance will rise, which results in a higher current.
    b. Organic materials, which contain N, P, S.
    Heavy metals like Sn, PB, Hg, Sb, Bi, As, etc.

Installation

  • Check the correct function of the Flex Strip, but in unrolled shape, before fixing it. Complaints after installation can not be accepted.
  • Switch off the mains supply and secure it against switching on.
  • Please check if the correct units will be installed, this means that the power supply must have the same voltage like the connected Flex Strip.
  • Please check if the power supply has enough power, for example, to compensate power loss due to long cables and if the correct cables are used to minimize voltage loss. It is suggested that the power supply has ca. 20% more power than the connected load.
  • When connecting the cables, please take care about the polarity.
  • Adhesive surface must be non-conductive. It is recommended to stick the Flex Strips into anodized aluminum profiles.
  • Flex Strip can only be bend sharply at areas with no electrical components. The minimum bending radius is 2 cm. Flex Strip is not allowed to be twisted.

PROLED IP20 Flex Lighting Strip-fig6

  • Installation must be made on a heat disposal underground, which is adequately dimensioned, to remove the heat of the desired Flex Strip. The underground must be free of greas, oil, silicone, dust, and dirt. We suggest Isopropanol for cleaning.
  • Installation on uneven, low heat-conductive grounding is not suggested as the lifetime will be shorted and make fixing difficult. These include wood, plasterboard, wallpaper, etc.
  • Avoid fixing over profile splice. Because of thermal expansion or shrinking damage to Flex Strip can happen. Divide the Flex Strip in this case and use flexible connections, for example, a wire strap.
  • Installation must be made on a heat disposal underground, which is adequately dimensioned, to remove the heat of the desired Flex Strip. The underground must be free of greas, oil, silicone, dust, and dirt. We suggest Isopropanol for cleaning.
  • Installation on uneven, low heat-conductive grounding is not suggested as the lifetime will be shorted and make fixing difficult. These include wood, plasterboard, wallpaper, etc.
  • Avoid fixing over profile splice. Because of thermal expansion or shrinking damage to Flex Strip can happen. Divide the Flex Strip in this case and use flexible connections, for example, a wire strap.

Installation steps:

  1. Remove the protection foil of the adhesive tapePROLED IP20 Flex Lighting Strip-fig7

  2. Place the Flex Strip in the profile and stuck it gently. Do not use any sharp or metallic tools.
    PROLED IP20 Flex Lighting Strip-fig8

  3. Cutaway the not needed part of the Flex Strip, with a scissor, at the marked cutting line.
    PROLED IP20 Flex Lighting Strip-fig9

  4. Please pay attention, that an already stuck Flex Strip should not be removed again. It is possible that electronical parts or soldering points will break, which isn’t covered by a guarantee or warranty.

  5. Rest pieces can be used for other project. Only connection cable must be soldered to the Flex Strip.

PROLED IP20 Flex Lighting Strip-fig10

Connection diagram

Following diagrams show the connection of Flex Strips. Please refer to the manual of your controller/dimmer for exact connection diagram.
Connection of monochromatic Flex Strips without dimmer

PROLED IP20 Flex Lighting Strip-fig11

Connection of monochromatic Flex Strips with dimmer

PROLED IP20 Flex Lighting Strip-fig12

Connection of RGB Flex Strips with Dimmer

PROLED IP20 Flex Lighting Strip-fig13

Soldering of cables at IP53 Flex Strips

If you have to solder a connection to a Flex Strip IP53, please work according to following steps.

PROLED IP20 Flex Lighting Strip-fig14| PROLED IP20 Flex Lighting Strip-fig15
---|---
Cut the Flex Strip on the marked cutting line.| Remove silicone from the soldering pads and Solder the cable correctly. Please take care about the correct polarity.
PROLED IP20 Flex Lighting Strip-fig16| PROLED IP20 Flex Lighting Strip-fig17
Cover the soldering point with acid-free silicone for example PROLED sealing glue L6396.| Cut a small piece of heat shrink tube.
PROLED IP20 Flex Lighting Strip-fig18| PROLED IP20 Flex Lighting Strip-fig19
Cover the soldering point with a heat shrink tube| Take care that the security foil of the adhesive tape can be removed.

Soldering of cables at IP68 Flex Strips

If you have to solder a connection to a Flex Strip IP68, please work according to following steps. Please be advised, that correctly sealed end caps have only a IP65 classification.

PROLED IP20 Flex Lighting Strip-fig20| PROLED IP20 Flex Lighting Strip-fig21
---|---
Cut the Flex Strip on the marked cutting line.| Remove the silicone from the soldering pads. Solder the cable correctly. Please take care about the correct polarity.
PROLED IP20 Flex Lighting Strip-fig22| PROLED IP20 Flex Lighting Strip-fig23
Cut a hole for the power cable into the end cap.| Move the end cap over the cable.
PROLED IP20 Flex Lighting Strip-fig24| PROLED IP20 Flex Lighting Strip-fig25
Pierce the tube outlet with the cap of the sealing glue, for example, PROLED L6396.| Screw the outlet funnel on the tube.
PROLED IP20 Flex Lighting Strip-fig26| PROLED IP20 Flex Lighting Strip-fig27
Cut the funnel diagonally.| Fill the end cap completely with the glue.
PROLED IP20 Flex Lighting Strip-fig28| Move the end cap over the strip, so that the soldering pads are covered.

Caution:
Please leave a new glued end cap minimum 24 h without movement for drying. Please be advised, that silicone is not maintenance-free. The glue must be checked regularly, but at least once a year, and must be replaced if needed.

Fixing of IP68 Flex Strips

For fixing Flex, Strip IP68 is possible with corresponding plastic clips.
If they can’t be used, the IP68 Flex Strip must be secured with suitable glue. The existing 3M tape is only applicable as installation help, but not for long-term fixing.
Following please see examples, of how they can be attached.

PROLED IP20 Flex Lighting Strip-fig29

Please note the permitted bending radius!

PROLED IP20 Flex Lighting Strip-fig30| Flex Strips have been installed before finishing the room. During painting, work paint has been placed on LED and caused a color shift.
---|---
PROLED IP20 Flex Lighting Strip-fig31| Placing of the strip wasn’t made equal over the whole length. Due to this, the light output is different in some positions.
PROLED IP20 Flex Lighting Strip-fig32| Supply cable wasn‘t placed correctly. Shadow of cables is visible on the wall.

Installation manual
02.22 Technical amendments reserved

MBN GmbH, Balthasar-Schaller-Str. 3, 86316 Friedberg – Germany
www.proled.com

Documents / Resources

| PROLED IP20 Flex Lighting Strip [pdf] User Manual
IP20, IP53, IP68, Flex Lighting Strip
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals