HORMANN MWB2 Wheel Locking System Instruction Manual

September 16, 2024
HORMANN

MWB2 Wheel Locking System

Specifications:

  • Product Name: IBS
  • Model Number: 1200024381
  • Version: 08.2024

Product Information:

The IBS system is designed for adjustment work and operation of
dock levellers. It includes sensors for intermediate stops and
platform positioning, with safety measures to prevent injury or
product damage.

Product Usage Instructions:

Safety:

  1. Read and follow the instructions carefully.

  2. Observe the instructions for the dock leveller and control
    system.

  3. Keep these instructions accessible at all times.

  4. Only allow authorized and instructed personnel to work on the
    product.

Adjustment:

  1. Determine the position X for the sensor holder as per the table
    provided.

  2. Reposition the sensor holder by moving it to the required
    position.

  3. Loosen the sensor and shift it in the holder for horizontal
    alignment.

Operation and Functional Progress:

Follow the brief instructions provided for operating the dock
leveller. Avoid driving over the dock leveller in the intermediate
stop to prevent injury and damage.

Maintenance:

  • Perform a function check as part of regular maintenance of the
    dock leveller.

Malfunctions and Troubleshooting:

Ensure all 3 sensors are set and switched correctly to maintain
trouble-free operation of the IBS system.

FAQ:

Q: What should I do if the warning lamp flashes during

operation?

A: If the warning lamp flashes, do not drive over the dock
leveller in the intermediate stop. The platform can only be loaded
to a limited extent in this position to avoid injury and
damage.

IBS

1200024381 / 08.2024

EN

Instructions for adjustment work and operating
IBS

Dissemination as well as duplication of this document and the use and communication of its content are prohibited unless explicitly permitted. Noncompliance will result in damage compensation obligations. All rights reserved in the event of patent, utility model or design model registration. Subject to changes.
HÖRMANN KG Verkaufsgesellschaft Upheider Weg 94 ­ 98 33803 Steinhagen Germany www.hoermann.com
ENGLISH

SAfEty

1

Safety

Dimensions and legend

If the instructions are not followed, this could result in

NL

Y

injury or damage to the product.

X

Read and follow the instructions carefully.

12

Observe the instructions for the dock leveller and the control 560 T/V.

Keep these instructions accessible at all times.

3

Only allow persons to work on the product who have

been authorised and instructed by the operator.

This applies to fitters, maintenance personnel and

operators.

2

Description

IBS is a semi-automatic intermediate stop when extending and retracting the telescopic lip. The equipment is suitable for Hörmann telescopic lip dock levellers with control 560 T/V.

3

Electrical connection

See the control documentation.

1, 2 Sensors for intermediate stop 3 Sensor for platform position X Position of the sensor holder Y Intermediate stop of extension range NL Dock leveller length (see data label)

4.1

Intermediate stop

4

Adjustment

Ensure that the following conditions are met when performing adjustment work: ­ The working area is cordoned off. ­ The control is secured against unauthorised operation. ­ The dock leveller is undamaged and in a proper state. ­ Cables are not kinked, squeezed or damaged. ­ The dock leveller is secured using the maintenance support.

Y Y
1. Measure the required extension range (Y) for the intermediate stop of the telescopic lip. ­ When installed at the factory, the intermediate stop is preset to an extension range of 100 mm. ­ Maximum extension range (Ymax) = distance between front edge platform and front edge buffer
2. Determine the position X for the sensor holder, see table “Determination of position X”.

Determination of position X Position X = extension range Y + table value

Dock leveller type*
HTL2 / HRT 60 kN
HTL2 100 kN
HTL2 ISO HTLV4

Length of lip (L)* 1000 1200 1000 1200
950 / 1150 1000

2000 200 — ­10 — 100 —

  • See data label

2

2500 700 500 490 290 400 —

Dock leveller length (NL)*

2750 3000 3500 4000

950

1200 1700 2200

750

1000 1500 2000

740

990

1490 1990

540

790

1290 1790

650

900

1400 1900

1205 1705 2205

4500 2700 2500 2490 2290 2400 2705

5000 3200 3000
— — — —

1200024381 / 08.2024

If the length of the dock leveller differs, use the following formula: X = Y + NL ­ L ­ type-dependent value Type-dependent values · HTL2 / HRT 60 kN: 800 · HTL2 100 kN: 1010 · HTL2 ISO: 950 · HTLV4: 795
The sensor holder is fastened using a magnet. To change the position, move the sensor holder.

Changing the position

ADjuStmEnt
+ –

8
7 6
5 4 3 2 1

Reposition the sensor holder. Measure the distance from the inside of the rear rail of the platform.

4.2

Platform position

The IBS system is installed at the factory in such a way that the platform is aligned horizontally in the intermediate stop. Chamfered alignment is possible.

24
Loosen the sensor. Shift the sensor in the holder.
Adjustment for horizontal position (factory setting) The values correspond to the sensor position on the scale of the holder.
Dock leveller length (NL)*

2000 2500 2750 3000 3500 4000 4500 5000

Type

HTL2 60 kN 4 2 4 3 6 5 4 4 ­ 5

HTL2 Jumbo*

———— 9

8

HTL2 100 kN

1 2 4 3 6­7 5­6 4­5 —

HRT

8 6 5 4­5 8 6 5 4­5

HTL2 ISO 2 2 4 3 6 5 4 —

HTLV4

— — — 7 6 11 9

  • Dock leveller in installation height > 750 mm

1200024381 / 08.2024

3

OPERAtIOn AnD funCtIOnAl PROGRESS

5

Operation and functional

progress

Note the brief instructions.

WARnInG
Danger of injury and damage when driving over the dock leveller in the intermediate stop.
The platform can only be loaded to a limited extent in the intermediate stop. The warning lamp flashes. Do not drive over the dock leveller in the
intermediate stop.

6

maintenance

6.1

Checking and maintenance

Perform a function check as part of the maintenance of the dock leveller.

6.2

malfunctions and troubleshooting

All 3 sensors must be set and switched correctly to ensure trouble-free operation of the IBS system.

12

5.1

Before the loading process

1. Press the Extend lip button. Keep the button pressed. The platform lifts. The lip extends to the preset length. The platform lowers. The warning lamp flashes. It is possible to access the dock leveller, e.g. to open vehicle doors.
2. Press the Lift platform button. Keep the button pressed until the platform is above the level of the loading surface. The warning light goes out.
3. Press the Extend lip button within the next second. Press and hold the button until the lip is extended as far as needed and no further.
4. Release the button.
The lip is lowered to the loading surface after approx. one second.

Correct the lip: In order to retract the lip again, use the Retract lip
button.

5.2

After the loading process

1. Press the Return or Retract lip button 1x. The platform lifts. The lip retracts to the preset length. The platform lowers. The warning lamp flashes. It is possible to access the dock leveller, e.g. to close vehicle doors.
2. Press the Return or Retract lip button 1x. The dock leveller will automatically move into the home position.

3

The sensor holder for sensor 1 and 2 must be at the bottom of the platform beam.
Sensor 3 must be able to detect the bolt of the hose clamp.

malfunction The lip does not stop in preset position

Sensor 1

The warning light on the control does not

2

switch on or off

The platform does not stop in preset

3

position

troubleshooting Check whether the sensor switches properly. Hold a
metal object in front of the sensor. When the sensor switches, the sensor LED lights up.
The sensor switches. Correct the position of the sensor.
The sensor does not switch. Perform the following measures:
­ Remove any contamination. ­ Check the connections. Correct if necessary. ­ Check the components for damages. Replace
defective components. ­ Fasten loosely hanging cables.

4

1200024381 / 08.2024