freddox FD-VG90 Vacuometer User Manual
- June 1, 2024
- freddox
Table of Contents
freddox FD-VG90 Vacuometer
Specifications
- Product Name: VACUOMETER FD-VG90
- Accuracy: ±0.1
- Resolution: 0.01
- Battery Life: Up to 100 hours
- Maximum Overload Pressure: 1000 psi
- Operating Temperature: 0°C to 50°C
- Buzzer Alarm: Yes
- Inlet Port: 1/4 inch NPT
FUNCTION MANUAL OF DIGITAL VACUUM GAUGE
- The Freddox FD-VG90 is your solution for precise vacuum measurement within your circuits, ensuring moisture-free and optimal conditions before charging. This tool offers a high-quality sensor that guarantees accurate results.
- The Freddox Vacuometer achieves measurements with remarkable precision, accurate to 0.1 microns. Its built-in target alert function notifies you promptly once the desired vacuum level has been achieved.
- Designed with portability in mind, the FD-VG90 features a compact form and offers an extended battery life. It includes an automatic power-off function, making it an indispensable companion for your day-to-day operations.
FEATURES
- Measurement mode: Absolute pressure (ATM~0.1Pa)
- Vacuum Unit: Pa, mBar, mmHg, Micron
- Resolution: 0.1 Pa (maximum pressure)
- Target vacuum alert function available
- Portable design, battery power display
- In atmosphere condition, shown “—–” on LCD
TECHNICAL PARAMETER
Project | Description |
---|---|
Range | 99999Pa~0.1Pa, 740000~0.75 Micron |
Accuracy | 0.1Pa~1000Pa; Reading ± 5% (at 20°C) |
Resolution | 0.1Pa(<10Pa); 1Pa(<100Pa); 10Pa(<1000Pa) |
Unit | Pa, mBar, mmHg, mTorr, InHg, Microns |
Battery Life | 40 Hours (3 x AA Battery) |
Maximum Overload Pressure | 0.5 Mpa / 72 Psi |
Operating Temperature | -5~50°C (-23~122°F |
Buzzer Alarm | 90 db, shutdown after 10 seconds |
Inlet Port | 7 / 16” ~ 20UNF (1 / 4” SAE) |
OPERATING INSTRUCTIONS
-
TURN ON / OFF
Press “ON” to turn on. Press and hold to turn it off. -
UNIT SWITCH
Press “UNIT” to switch units. -
BACKLIGHT ON / OFF
Press “ON” to turn ON/OFF. To save battery power, the backlight will turn off automatically after 15 seconds. -
ALERT SETTINGS
When the vacuum pressure reaches the set pressure, an alert will be activated (screen flicker, buzzer beeps). Press any key to quit the alert or wait 35 seconds, alert will automatically stop.
TARGET VACUUM SETTING
- Press “SET” to activate the target vacuum set mode, and the LCD will flicker.
- Press “UNIT” to set the target vacuum. The chosen digit will flicker.
- Press “SET” to choose “0-9”.
- After the target vacuum is set, press “SAVE CAL” to save and activate monitor mode.
- After monitor mode is activated, the buzzer beeps periodically.
- In monitoring mode, if the vacuum pressure is lower than the set pressure, an alert will be activated.
- Press and hold “SET” to quit monitor mode.
VACUUM GAUGE CALIBRATION
- When the vacuum measured by the vacuum meter is deviated, calibration is needed.
- There are three kinds of calibration: Atmosphere calibration, Ultimate calibration and custom Calibration.
- When the vacuum gauge is in atmosphere condition and if LCD doesn’t show the following “- – – – -”, atmosphere calibration is needed.
- When ultimate vacuum data is different from standard vacuum gauge data, ultimate calibration is needed.
ATMOSPHERE CALIBRATION
Press and hold “SAVE CAL” to activate atmosphere calibration. LCD shown
“-CALI-” means calibration success.
ULTIMATE CALIBRATION
- Note: use this calibration only when the vacuum is around 0.5 Pa. Otherwise it may affect the accuracy of measurement.
- Press an old “SAVE CAL” + “SET” to activate ultimate calibration. If calibration succeeds, the LCD screen will show “CAL 1” otherwise a “ERROR” will be shown.
CUSTOM CALIBRATION
Note: To achieve a better measurement result, calibrating at high vacuum
conditions is recommended,
ENTERING CONFIGURATION MODE
Press and hold “UNIT” + “SET” when the vacuum gauge has just been turned on.
Configuration mode will be activated (LCD will show 1-HI)
ENTERING CUSTOM CALIBRATION MODE
Press “SET” and shift to the configuration function “2-LO”. Then press “SAVE
CAL” to confirm. Custom calibration mode will be activated. (LCD digit will
flicker).
-
CONNECT VACUUM GAUGE TO VACUUM PUP AND START VACUUM PUMP
Ensure the vacuum gauge is connected to the vacuum pump tightly, and start the vacuum pump. -
VACUUM DISPLAY ADJUST
Compare the vacuum display on the standard vacuum gauge and vacuum pump and adjust display data. Press “SET” to increase (press and hold to accelerate increase), press “UNIT” to decrease (press and hold to accelerate decrease). -
SAVE DATE
When the display on the vacuum pump is consistent with the standard gauge, save the calibration data and exit (press “ON” to end adjustment, now vacuum gauge returns to configuration mode, and LCD shows “2-LO”). **** -
RETURN TO WORKING MODE
Press “ON” to save and return to working mode, calibration is finished.
Manufacturer reserves the right to change any product specifications without notice.: BeijerRefAB_VacuumPumpInstructionManual_Freddox_23_EN
MORE INFORMATION
BEIJER REF AB
Stortorget 8
a215 37 Malmö
Sweden
Tel. +46 (0)40 611 21 50 For more information, please visit :
www.beijerref.com
Frequently Asked Questions
- Q: How do I change the battery in the VACUOMETER FD-VG90?
- A: To change the battery, carefully follow the instructions in the user manual. Make sure to use the specified type of battery for optimal performance.
- Q: Can I recalibrate the VACUOMETER FD-VG90?
- A: Yes, you can recalibrate the device following the recalibration instructions provided in the user manual. It is recommended to recalibrate periodically for accurate readings.