MEAN WELL XLC-25 Series 25W Multiple Stage Constant Power Constant Voltage LED Driver Owner’s Manual
- September 7, 2024
- MEAN WELL
Table of Contents
MEAN WELL XLC-25 Series 25W Multiple Stage Constant Power Constant
Voltage LED Driver
Product Specifications
- Model: XLC-25 series
- Power Output: 25W
- Input Voltage: 176-280 VDC
- Output Modes: Constant Power Mode, Constant Voltage Mode (12V/24V)
- Housing: Plastic with Class II and PFC design
- Compliance: UL 8750 Class 2 / Class P, CE ErP directive
- Additional Features: Flicker-free, Standby Power Consumption
Product Usage Instructions
Installation
- Ensure input power is within the specified range (176-280 VDC).
- Connect the driver to the LED lighting system according to the wiring diagram provided.
Output Mode Selection
- For XLC-25-S Series (Independent Type): Select output mode using dip switch settings.
- For XLC-25 Series (Built-in Type): Output mode can be adjusted via NFC settings.
Power Adjustment
- Choose between Constant Power Mode or Constant Voltage Mode based on your LED lighting requirements.
Safety Precautions:
- Ensure proper grounding during installation.
- Do not exceed the maximum load capacity of the driver.
Frequently Asked Questions (FAQ)
-
Q: Can this LED driver be used with outdoor lighting fixtures?
A: Yes, as long as the driver is installed in a suitable outdoor-rated enclosure to protect it from environmental elements. -
Q: How do I reset the output mode if I have selected the wrong setting?
A: To reset the output mode, power off the driver, make the necessary adjustments using the dip switches or NFC settings, and then power it back on.
25W Multiple-Stage Constant Power/Constant Voltage LED Driver
Features
- Constant power mode output with multiple stage selectable by dip switch or NFC setting(H-type)
- Constant voltage mode output (12V/24V)
- Plastic housing with class II and PFC design
- Meet UL 8750 Class 2 / Class P power unit
- Flicker free, complying with CE ErP directive
- Standby power consumption <0.5W
- Meet emergency lighting (EL) application
- Minimum dimming level 0.1% (DALI-2 DT6)
- Dimming functions: 3 in 1 dimming (Dim-to-off) DALI-2 + Push dimming
- 5 years warranty
Applications
- Recessed Light
- Down Light
- Panel Light
- Commercial Lighting
- Decorative Lighting
- LED strip lighting
- DALI digital Lighting
- GTIN CODE MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
XLC-25 Series is a 25W with constant power and constant voltage output LED
driver. It can operate from 100~305VAC and output current ranging between 300
mA to 1050 mA selectable by dip switch or NFC setting. Thanks to high
efficiency up to 88%, it is able to operate for -25°C ~85°C case temperature
under free air convection. XLC-25 is designed based on latest safety
regulations with 3 in 1 and DALI-2 dimming. XLC-25 can also be adjusted for
brightness with a push button as a simple way dimming, so it provides more
flexibility for LED Lighting application.
Model Encoding
Type | Function | Note |
---|---|---|
Blank | H type output current selectable by DIP-switch or NFC setting | In stock |
12, 24V Constant voltage output
B| H type output current selectable by DIP-switch or NFC with 3 in 1 dimming
DA2| H type output current selectable by DIP-switch or NFC with DALI-2 dimming
Note
- 12V/24V without dimming function.
- NFC current setting is available for XLC-25-H type only.
SPECIFICATION
MODEL | XLC-25-12- | XLC-25-24- |
---|
OUTPUT
| RATED VOLTAGE| 12V| 24V
RATED CURRENT| 2.1A| 1.05A
RATED POWER| Note.2| 25.2W| 25.2W
RIPPLE & NOISE (max.) **Note.3| 120mVp-p| 240mVp-p
VOLTAGE TOLERANCE Note.4| ±4.0%
LINE REGULATION| ±0.5%
LOAD REGULATION| ±2.0%
SETUP, RISE TIME Note.5**| 500ms, 100ms/230VAC, 1000ms, 100ms/115VAC
INPUT
| VOLTAGE RANGE| 100 ~ 305VAC| 141 ~ 400VDC| | |
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR| PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load
(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section)
TOTAL HARMONIC DISTORTION| THD<10%(@load≧50%/230VAC; @load≧75%/277VAC),
THD<15%(@load≧50%/115VAC) (Please refer to “TOTAL HARMONIC DISTORTION(THD)”
section)
EFFICIENCY (Typ.)| 86%| 88%
AC CURRENT| 0.35A / 115VAC| 0.18A / 230VAC| 0.15A/277VAC| |
INRUSH CURRENT(Typ.)| COLD START 10A(twidth=100 μ s measured at 50%
Ipeak) at 230VAC ; Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 71 units (circuit breaker of
type B) / 71 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA / 277VAC
PROTECTION
| OVER LOAD| 105 ~ 220% rated output power
Protection type:Hiccup mode , recovers automatically after fault condition is
removed
SHORT CIRCUIT| Hiccup mode, recovers automatically after fault condition
is removed
OVER VOLTAGE
| 13 ~ 16V| 26 ~ 32V
Shut down and latch off o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down output voltage, recovers automatically after
fault condition is removed
ENVIRONMENT
| WORKING TEMP.| Tcase=-25 ~ 85℃ (Please refer to “ OUTPUT LOAD vs
TEMPERATURE” section)
MAX. CASE TEMP.| Tcase=85℃
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X,
Y, Z axes
SAFETY & EMC
| ****
SAFETY STANDARDS
| ENEC BS EN/EN61347-1, BS EN/EN61347-2-13(EL) appendix J suitable for emergency installations(DC input 176-280VDC);
BS EN/EN62384 independent, GB19510.14, GB19510.1, EAC TP TC 004,UL8750(Class P); CSA C22.2 No. 250.13-12; approved;
Design refer to AS/NZS 61347-1, AS/NZS 61347-2-13
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC
ISOLATION RESISTANCE| I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
| Parameter| Standard| Test Level/Note
Conducted| BS EN/EN55015(CISPR15) ,GB/T 17743| —–
Radiated| BS EN/EN55015(CISPR15) ,GB/T 17743| —–
Harmonic Current| BS EN/EN61000-3-2 , GB17625.1| Class C @load≥50%
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY
| BS EN/EN61547
Parameter| Standard| Test Level/Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 2
EFT/Burst| BS EN/EN61000-4-4| Level 2
Surge| BS EN/EN61000-4-5| Level 3, 1KV/Line-Line
Conducted| BS EN/EN61000-4-6| Level 2
Magnetic Field| BS EN/EN61000-4-8| Level 2
Voltage Dips and Interruptions| BS EN/EN61000-4-11| 70% residual voltage for
10
period, 0% residual voltage for 0.5 periods
OTHERS
| FLICKER Note.6| PstLM ≤ 1, SVM ≤ 0.4
MTBF| 3949.8 K hrs min. Telcordia SR-332 (Bellcore) ; 338.5
Khrs min. MIL-HDBK-217F (25℃)
DIMENSION| 1474032mm,1074032mm (LWH)
PACKING| 141.6g; 60pcs/8.4Kg/0.58CUFT(for blank type); 160g;
50pcs/8.1Kg/0.57CUFT(for S-type)
NOTE|
-
All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
-
De-rating may be need under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
-
Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor.
-
Tolerance: includes set up tolerance, line regulation and load regulation.
-
Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
-
Flicker is measured at full load with the light source provided by MEAN WELL.
-
To fulfill requirement of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to the mains.
-
The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf))
-
The ambient temperature de-rating of 3.5℃/1000m with fanless models and 5℃/1000m with fan models for operating altitudes higher than 2000m(6500ft).
-
This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 70℃ or less.
-
For XLC(except -S) series: RCM is on a voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1.
For XLC-S series: RCM is on a voluntary basis. Non IC classification Independent LED control gear is not suitable for residential installations. -
Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information.
-
For more information, please contact with MEAN WELL sales.
※Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer .aspx
MODEL | XLC-25-H- |
---|
OUTPUT
| OPEN CIRCUIT VOLTAGE Note.2| 60V
DEFAULT CURRENT| 700mA
CURRENT ADJ.RANGE (BY DIP SWITCH OR NFC)| 0.3~1.05A
CONSTANT CURRENT REGION Note.3| 9~54V
RATED POWER Note.4| 25W
CURRENT RIPPLE| <4%
CURRENT TOLERANCE| ±5%
DIMMING RANGE| 0~100%
SETUP, RISE TIME Note.5,6| 500ms, 100ms/230VAC, 1000ms, 100ms/115VAC
INPUT
| VOLTAGE RANGE| 100~ 305VAC| 141 ~ 400VDC| |
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR| PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full
load
(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section)
**TOTAL HARMONIC DISTORTION**| THD<10%(@load≧50%/230VAC; @load≧75%/277VAC), THD<15%(@load≧50%/115VAC)
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
EFFICIENCY (Typ.) Note.7| 88%
AC CURRENT| 0.35A / 115VAC| 0.18A / 230VAC 0.15A/277VAC| |
INRUSH CURRENT(Typ.)| COLD START 10A(twidth=100 μ s measured at 50%
Ipeak) at 230VAC ; Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 71 units (circuit breaker of
type B) / 71 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA / 277VAC
STANDBY POWER CONSUMPTION Note.8| Standby power consumption<0.5W(Dimming
off)
PROTECTION
| SHORT CIRCUIT| Hiccup mode, recovers automatically after fault
condition is removed
OVER TEMPERATURE| Blank & B type: De-rating to lowest output level.
Recovers automatically after fault condition is removed.
DA2 type: Stage 1: De-rating to 75% loading; Stage 2: De-rating to 50%
loading. Recovers automatically after fault condition is removed.
ENVIRONMENT
| WORKING TEMP.| Tcase=-25 ~ 85℃ (Please refer to “ OUTPUT LOAD vs
TEMPERATURE” section)
MAX. CASE TEMP.| Tcase=85℃
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X,
Y, Z axes
SAFETY & EMC
| **SAFETY STANDARDS**| ENEC BS EN/EN61347-1, BS EN/EN61347-2-13(EL) appendix J suitable for emergency installations(DC input 176-280VDC);
BS EN/EN62384 independent, GB19510.14, GB19510.1, EAC TP TC 004,UL8750(Class P); CSA C22.2 No. 250.13-12 approved;
Design refer to AS/NZS 61347-1, AS/NZS 61347-2-13 ;
DALI STANDARDS| Comply with IEC62386-101,102,207
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC
ISOLATION RESISTANCE| I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
| Parameter| Standard| Test Level/Note
Conducted| BS EN/EN55015(CISPR15) ,GB/T 17743| —–
Radiated| BS EN/EN55015(CISPR15) ,GB/T 17743| —–
Harmonic Current| BS EN/EN61000-3-2 , GB17625.1| Class C @load≥50%
Voltage Flicker| BS EN/EN61000-3-3| —–
**EMC IMMUNITY| BS EN/EN61547
Parameter| Standard| Test Level/Note**
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 2
EFT/Burst| BS EN/EN61000-4-4| Level 2
Surge| BS EN/EN61000-4-5| Level 3, 1KV/Line-Line
Conducted| BS EN/EN61000-4-6| Level 2
Magnetic Field| BS EN/EN61000-4-8| Level 2
Voltage Dips and Interruptions
| ****
BS EN/EN61000-4-11
| 70% residual voltage for 10
period, 0% residual voltage for 0.5 periods
OTHERS
| FLICKER Note.9| PstLM ≤ 1, SVM ≤ 0.4
MTBF| 3949.8 K hrs min.| Telcordia SR-332 (Bellcore) ;| 338.5 Khrs min.|
MIL-HDBK-217F (25℃)
DIMENSION| 1474032mm,1074032mm (LWH)
PACKING| 141.6g; 60pcs/8.4Kg/0.58CUFT(for blank type); 160g;
50pcs/8.1Kg/0.57CUFT(for S-type)
NOTE|
- All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
- Output hiccups under no-load condition.
- Please refer to “DRIVER METHODS OF LED MODULE”.
- De-rating may be need under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
- Based on IEC 62386-101/102 DALI power on timing and interruption regulations, the set up time needs to test with a DALI controller w hich can support for DALI power on function, otherwise the startup time will be higher than 0.5 second.
- Efficiency is measured at 500mA/50V output set by dip-switch or NFC.
- Standby power consumption is measured at 230VAC.
- Flicker is measured at full load with the light source provided by MEAN WELL.
- The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf))
- For XLC(except -S) series: RCM is on a voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1. For XLC-S series: RCM is on a voluntary basis. Non IC classification Independent LED control gear is not suitable for residential installations.
- To fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without permanently connected to the mains.
- This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 70℃ or less.
- The ambient temperature de-rating of 3.5℃/1000m with fanless models and 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information.
- For more information, please contact with MEAN WELL sales. ※Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer .aspx
BLOCK DIAGRAM
DRIVING METHODS OF LED MODULE
- I-V Operating Area
XLC-25-H
CONSTANT POWER TABLE
XLC-25-H is a multiple-stage constant power driver, selection of output
current through DIP switch or NFC setting is exhibited below.
Vo| DIP S.W
Io
| 1| 2| 3
---|---|---|---|---
9~54V| 300mA| —-| —-| —-
9~54V| 350mA| —-| —-| ON
9~54V| 400mA| —-| ON| —-
9~50V| 500mA| —-| ON| ON
9~42V| 600mA| ON| —-| —-
9~36V| 700mA(default)| ON| —-| ON
9~28V| 900mA| ON| ON| —-
9~24V| 1050mA| ON| ON| ON
Note: The operating voltage range which show on this table is recommend to use.
NFC Function Description
- The output current of the NFC Mode LED driver can be adjusted using NFC via the mobile APP.
Operation Instruction:
Compatible phone
Install an NFC-compatible smart mobile device or phone with AndroidTM 4.1 or
IOS12 updates.
Steps for setting output current via NFC
- Download Meanwell APP on mobile device or mobile phone, and enable NFC function.
- Check the NFC antenna position of the mobile phone please.
- Enter Meanwell APP ->Top left menu –Installation Manual/APP->PowerNFC,approach the LED driver NFC sensing position and perform sensing.
- APP displays the functional parameters, and the relevant parameters are modified as required.
- Tap the APP write button and quickly move the phone antenna close to the NFC sensing position of the LED driver.
- The write completes when the mobile phone displays”Success”.
APP Function Description
- APP Interface:
To be used through APP available on Apple Store and Google Play Store for iOS and Android. Search: MEAN WELL on
Note:
- Current accuracy : the numerical error between the set current and the actual current is within 2%.
- Please turn off the input power supply to the LED driver when using NFC function.
DIMMING OPERATION
B type
3 in 1 dimming function
- Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-: 0 ~ 10VDC, or 10V PWM signal or resistance.
- Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers.
- Dimming source current from power supply: 100 A (typ.)μ
Applying additive 0 ~ 10VDC
Applying additive 10V PWM signal (frequency range 300Hz~3KHz):
Applying additive resistance: 0~100kΩ
Note
- Min. dimming level is about 8% and the output current is not defined when 0%< Iout<8%.
- The output current could drop down to 0% when dimming input is about 0kΩ or 0Vdc, or 10V PWM signal with 0% duty cycle.
DIMMING OPERATION
◎ DA2 type (DALI-2 digital dimming function)
※ Input wiring diagram
- PUSH dimming (primary side)
- The factory default dimming level is at 100%.
- If the push action lasts less than 0.05 sec., it will not lead to a change for the status of the driver.
- Up to 10 drivers can perform the PUSH dimming at the same time when utilizing one common push button. The maximum length of the cable from the push button to the last driver is 20 meters.
Action | Action duration | Function |
---|---|---|
Short Push | 0.1~1s | Turn ON-OFF the driver |
Double Click | Click twice in 1.5s | Set up the dimming level to 100% |
Long Push | 1.5~10s | Every Long Push changes the dimming direction, |
dimming up or down
OUTPUT LOAD vs TEMPERATURE
STATIC CHARACTERISTIC
LIFE TIME
TOTAL HARMONIC DISTORTION (THD)
XLC-25-H,Tcase at 75℃
POWER FACTOR (PF) CHARACTERISTIC
XLC-25-H,Tcase at 75℃
EFFICIENCY vs LOAD
XLC-25 series possess superior working efficiency that up to 88% can be
reached in field applications.
XLC-25-H,Tcase at 75℃
MECHANICAL SPECIFICATION
(XLC-25 Built-in Type)
MECHANICAL SPECIFICATION
(XLC-25-S Independent Type)
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>