MEAN WELL LRS-50 Series 50W Single Output Switching Power Supply Instruction Manual

October 27, 2023
MEAN WELL

LRS-50 Series 50W Single Output Switching Power Supply
Instruction Manual

LRS-50 Series 50W Single Output Switching Power Supply

50W Single Output Switching Power Supply

Features

  • Universal AC input / Full range
  • Withstand 300VAC surge input for 5 second
  • No load power consumption<0.3W
  • Miniature size and 1U low profile
  • High operating temperature up to 70°C
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • Compliance to IEC/BS EN/EN 60335-1(PD3) and IEC/BS EN/EN61558-1, -2-16 for household appliances
  • Operating altitude up to 5000 meters (Note.8)
  • Withstand 5G vibration test
  • High efficiency, long life and high reliability
  • LED indicator for power on
  • Over voltage category III
  • 100% full load burn-in test
  • 3 years warranty

Description

LRS-50 series is a 50W single-output enclosed type power supply with 30mm of low profile design. Adopting the full range 85-264VAC input, the entire series provides an output voltage line of 3.3V, 5V, 12V, 15V, 24V, 36V and 48V. In addition to the high efficiency up to 90%, the design of metallic mesh case enhances the heat dissipation of LRS-50 that the whole series operates from -30°C through 70°C under air convection without a fan. Delivering an extremely low no load power consumption (less than 0.2W), it allows the end system to easily meet the worldwide energy requirement. LRS-50 has the complete protection functions and 5G anti-vibration capability; it is complied with the international safety regulations such as TUV BS EN/EN62368-1, BS EN/EN60335-1,BS EN/EN61558-1/-2-16, UL62368-1 and GB4943. LRS-50 series serves as a high price-to-performance power supply solution for various industrial applications.

Applications

  • Industrial automation machinery
  • Industrial control system
  • Mechanical and electrical equipment
  • Electronic instruments, equipments or apparatus
  • Household appliances

GTIN CODE

MW Search https:Awatmeanwell.comiseMceGTIN.asax

Model Encoding

SPECIFICATION

MODEL| LRS-50-3.3| LRS-50-5| LRS-50-12| LRS-50-15| LRS-50-24| LRS-50-36| LRS-50-48
---|---|---|---|---|---|---|---









OUTPUT

| DC VOLTAGE| 3.3V| 5V| 12V| 15V| 24V| 36V| 48V
RATED CURRENT| 10A| 10A| 4.2A| 3.4A| 2.2A| 1.45A| 1.1A
CURRENT RANGE| 0 ~ 10A| 0 ~ 10A| 0 ~ 4.2A| 0 ~ 3.4A| 0 ~ 2.2A| 0 ~ 1.45A| 0 ~ 1.1A
RATED POWER| 33W| 50W| 50.4W| 51W| 52.8W| 52.2W| 52.8W
RIPPLE & NOISE (max.) Note.2| 80mVp-p| 80mVp-p| 120mVp-p| 120mVp-p| 150mVp-p| 200mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE| 2.97 ~ 3.6V| 4.5 ~ 5.5V| 10.2 ~ 13.8V| 13.5 ~ 18V| 21.6 ~ 28.8V| 32.4 ~ 39.6V| 43.2 ~ 52.8V
VOLTAGE TOLERANCE Note.3| ±3.0%| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION **Note.4| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION Note.5| ±2.0%| ±1.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 1000ms, 30ms/230VAC         2000ms,30ms/115VAC at full load
HOLD UP TIME (Typ.)**| 30ms/230VAC       12ms/115VAC at full load





INPUT

| VOLTAGE RANGE| 85 ~ 264VAC         120 ~ 373VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 80%| 83%| 86%| 88%| 88%| 89%| 90%
AC CURRENT (Typ.)| 0.95A/115VAC          0.56A/230VAC
INRUSH CURRENT (Typ.)| COLD START 45A/230VAC
LEAKAGE CURRENT| <0.75mA / 240VAC



PROTECTION

| ****

OVER LOAD

| 110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed


OVER VOLTAGE

| 3.8 ~ 4.45V| 5.9~ 7.3V| 13.8 ~ 17.2V| 18.7 ~25.75V| 28.8 ~ 36.6V| 41.4 ~ 51.6V| 55.2 ~ 67.8V
Protection type : Shut down o/p voltage, re-power on to recover





ENVIRONMENT

| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY| Ⅲ; Compliance to BS EN/EN61558, BS EN/EN50178, BS EN/EN60664-1, BS EN/EN62477-1; altitude up to 2000 meters




SAFETY & **EMC**

(Note 9)

| ****

SAFETY STANDARDS

| UL62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16,CCC GB4943.1, BSMI CNS14336-1, EAC TP TC 004, AS/NZS 60950.1(by CB),KC K60950-1(for LRS-50-12/24 only), BIS IS13252(Part1): 2010/IEC 60950-1: 2005 approved
WITHSTAND VOLTAGE| I/P-O/P:4KVAC I/P-FG:2KVAC  O/P-FG:1.25KVAC
ISOLATION  RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2,-3, GB/T 9254, BSMI CNS13438, EAC TP TC 020,KC KN32,KN35(for LRS-50-12/24 only)
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020,KC KN32,KN35(for LRS-50-12/24 only)


OTHERS

| MTBF| 3149.8K hrs min.Telcordia SR-332 (Bellcore) ;  561.6Khrs min. MIL-HDBK-217F (25℃)
DIMENSION| 998230mm (LWH)
PACKING| 0.23Kg; 60pcs/14.8Kg/0.88CUFT

Note

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. Line regulation is measured from low line to high line at rated load.
  5. Load regulation is measured from 0% to 100% rated load.
  6. Length of set up time is measured at cold first Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
  7. 3V,5V when the load factor 0~50%, the switching power less is reduced by burst operation, which will cause ripple and ripple noise to go beyond the specifications.
  8. The ambient temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m(6500ft).
  9. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMl testing of component power supplies.”(as available on http://www.meanwell.com)

※ Product Liability Disclaimer: For detailed information, please refer to https://[www.meanwell.com/serviceDisclaimer.aspx](http://www.meanwell.com/serviceDisclaimer.aspx)

Block DiagramMEAN WELL LRS-50 Series 50W Single Output Switching Power
Supply fig 3

Derating Curve

Static Characteristics

Mechanical Specification

MEAN WELL LRS-50 Series 50W Single Output Switching Power Supply
fig

Pin No.

| Assignment| Pin No.|

Assignment

---|---|---|---
1| AC/L| 4| DC OUTPUT -V
2| AC/N| 5| DC OUTPUT +V
3| Fig ≅| |

Installation **Manual
** Please refer to : http://www.meanwell.com/manual.html

https://www.meanwell.com/Upload/PDF/Enclosed_Type_EN.pdf

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals