Product Specifications

  • Model: LPV-35 series
  • Output:
    • LPV-35-5: 5V, 5A, 30W
    • LPV-35-12: 12V, 3A, 36W
    • LPV-35-15: 15V, 2.4A, 36W
    • LPV-35-24: 24V, 1.5A, 36W
    • LPV-35-36: 36V, 1A, 36W
  • Input Voltage Range: 90 ~ 264VAC, 127 ~ 370VDC
  • Frequency Range: 47 ~ 63Hz
  • Efficiency: 77% – 85%
  • Operating Temperature: -30°C to +70°C
  • IP Rating: IP67
  • Safety Standards: Ul1310 class 2, CAN/CSA No. 223-M91, BIS IS15885, IEC62368-1, EAC TP TC 004, BS EN/EN62368-1

Product Usage Instructions

Installation

  1. Ensure the input voltage matches the specified range.
  2. Connect the AC/N (Blue) and AC/L (Brown) wires to the corresponding terminals.
  3. Connect the +V (Red) and -V (Black) wires to the output terminals.
  4. Mount the power supply in the recommended direction for optimal performance.

Operation

  1. After installation, apply power within the specified input voltage and frequency range.
  2. Check for proper output voltage based on the model you are using.
  3. Avoid overloading the power supply beyond the rated current.

Maintenance

Regularly check for any abnormal noise or heating during operation. Ensure proper ventilation around the power supply unit to prevent overheating.

Features

  • Constant voltage design
  • Universal AC input / Full range
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • Fully encapsulated with IP67 level (Note.8)
  • Fully isolated plastic case
  • Class II power unit, no FG
  • Class 2 power unit
  • Pass LPS
  • Suitable for LED related fixtures or appliance (such as LED Decoration or Advertisement devices) (Note.12)
  • 100% full load burn-in test
  • Low cost, high reliability
  • 2 years warranty

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

SPECIFICATION

MODEL| LPV-35-5| LPV-35-12| LPV-35-15| LPV-35-24| LPV-35-36
---|---|---|---|---|---

OUTPUT

| DC VOLTAGE| 5V| 12V| 15V| 24V| 36V
RATED CURRENT| 5A| 3A| 2.4A| 1.5A| 1A
CURRENT RANGE| 0 ~ 6A (Note.7)| 0 ~ 3A| 0 ~ 2.4A| 0 ~ 1.5A| 0 ~ 1A
RATED POWER| 30W| 36W| 36W| 36W| 36W
RIPPLE & NOISE (max.) **Note.2| 80mVp-p| 120mVp-p| 120mVp-p| 150mVp-p| 150mVp-p
VOLTAGE TOLERANCE Note.3| ±6.0%| ±5.0%
LINE REGULATION| ±1.0%
LOAD REGULATION| ±4.0%| ±2.0%
SETUP, RISE TIME| Note.6| 500ms, 20ms / 230VAC 500ms, 20ms / 115VAC at full load
HOLD UP TIME (Typ.)**| 50ms/230VAC           16ms/115VAC at full load

INPUT

| VOLTAGE RANGE| Note.4| 90 ~ 264VAC           127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 77%| 84%| 84%| 85%| 85%
AC CURRENT (Typ.)| 1.1A/115VAC 0.7A/230VAC
INRUSH CURRENT(Typ.)| COLD START 55A(twidth=510μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| 0.25mA / 240VAC

PROTECTION

| OVERLOAD| 110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| 5.75 ~ 6.75V| 13.8 ~ 16.2V| 17.25 ~ 20.25V| 27.6 ~ 32.4V| 41.4 ~ 48.6V
Protection type : Shut down o/p voltage, re-power on to recover

ENVIRONMENT

| WORKING TEMP.| -30 ~ +65℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

SAFETY & EMC

| SAFETY STANDARDS| Ul1310 class 2, CAN/CSA No. 223-M91, BIS IS15885(Note 13), IEC62368-1, EAC TP TC 004, IP67, BS EN/EN62368-1 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC
ISOLATION RESISTANCE| I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2 Class A, BS EN/EN61000-3-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020

OTHERS

| MTBF| 5170.3K hrs min.       Telcordia SR-332 (Bellcore) ; 743.5Khrs min.| MIL-HDBK-217F (25℃)|
DIMENSION| 1484030mm (LWH)
PACKING| 0.34Kg; 40pcs/14.6Kg/0.70CUFT

NOTES:

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.

  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

  3. Tolerance: includes set up tolerance, line regulation and load regulation.

  4. Derating may be needed under low input voltage. Please check the static characteristics for more details.

  5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
    complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

  6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.

  7. LPV-35-5 can provide 6A of output current continuously. Based on the requirement of UL1310 class 2, the output current is only certified up to 5A for the test report of LPV-35-5

  8. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute.

  9. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).

  10. Products sourced from the Americas regions may not have the TUV/BIS/CCC logo. Please contact your MEAN WELL sales for more information.

  11. For any application note and IP water proof function installation caution, please refer our user manual before using.
    https://www.meanwell.com/Upload/PDF/LED_EN.pf

  12. This product is not intended for LED lighting luminaire applications in the EU. (In the EU the LPF/NPF/XLG series are recommended.)

  13. Products sourced from the China regions may not have the BIS logo, please contact your MEAN WELL sales for more information.
    Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.asox

Mechanical Specification

MEAN-WELL-LPV-35-12-Single-Output-Switching-Power-Supply-
fig-1

Recommend Mounting Direction

MEAN-WELL-LPV-35-12-Single-Output-Switching-Power-Supply-
fig-2

Block Diagram

MEAN-WELL-LPV-35-12-Single-Output-Switching-Power-Supply-
fig-3

Derating Curve

MEAN-WELL-LPV-35-12-Single-Output-Switching-Power-Supply-
fig-4

Static Characteristics

MEAN-WELL-LPV-35-12-Single-Output-Switching-Power-Supply-
fig-5

Frequently Asked Questions (FAQ):

Q: What should I do if the power supply overheats?

A: If the power supply overheats, immediately disconnect it from the power source and allow it to cool down before attempting operation.

Q: Can I use the LPV-35 series power supply outdoors?

A: Yes, the IP67 rating allows for safe outdoor usage, but ensure proper protection from direct exposure to elements like rain or snow.

Q: What is the maximum number of units I can connect to a circuit breaker?

A: You can connect up to 4 units with a circuit breaker of type B or up to 7 units with a circuit breaker of type C at 230VAC.