MEAN WELL IRM-15 Series Mount Green Power Module Owner’s Manual

October 30, 2023
MEAN WELL

IRM-15 Series Mount Green Power Module
Owner’s ManualMEAN WELL IRM 15 Series Mount Green Power Module -
Icon

Features

  • 2.06″x1.07″compact size
  • Universal input 85-305VAC
  • No load power consumption<0.1W
  • EMI Class B without additional components
  • Wide operating temp. range -30-70°C
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • Isolation Class II
  • Pass LPS
  • 3 years warranty

Applications

  • Industrial electrical equipment
  • Mechanical equipment
  • Factory automation equipment
  • Hand-held electronic device

GTIN CODE
MW Search. https://www.meanwell.com/serviceGTIN.aspx

Description

IRM-15 is a 15W miniature (52.427.224mm) AC-DC module-type power supply, ready to be soldered onto the PCB boards of various kinds of electronic instruments or industrial automation equipment’s. This product allows the universal input voltage range of 85-305VAC. The 94V-0 flame retardant plastic case and potted with silicone enhance the heat dissipation and meet the anti- vibration demand up to 5G;
moreover, it provides the fundamental resistance to dust and moisture.
With the high efficiency up to 83% and the extremely low no-load power consumption below 0.1W, IRM-15 series fulfills the worldwide regulation for the low power consumption requirement for electronics. The entire series is a Class II design (no FG pin), incorporating the built-in EMI filtering components, enabling the compliance with BS EN/EN55032 Class B; the supreme EMC features keep the end electronic units from electromagnetic interference.
Model Encoding

MEAN WELL IRM 15 Series Mount Green Power Module - Model
Incoding

SPECIFICATION

MODEL| IRM-15-3.3| IRM-15-5| IRM-15-12| IRM-15-15| IRM-15-24
---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 3.3V| 5V| 12V| 15V| 24V
RATED CURRENT| 3.5A| 3A| 1.25A| 1A| 0.63A
CURRENT RANGE| 0 ∼ 3.5A| 0 ∼ 3A| 0 ∼ 1.25A| 0 ∼ 1A| 0 ∼ 0.63A
RATED POWER| 11.55W| 15W| 15W| 15W| 15.12W
RIPPLE & NOISE (max.) Note.2| 200mVp-p| 200mVp-p| 200mVp-p| 200mVp-p| 200mVp-p
VOLTAGE TOLERANCE Note.3| ±2.5%| ±2.5%| ±2.5%| ±2.5%| ±2.5%
LINE REGULATION| ±0.5%| ±0.5%| ±0.3%| ±0.3%| ±0.3%
LOAD REGULATION| ±1%| ±1%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 1000ms, 20ms/230VAC
1000ms, 20ms/115VAC at full load
HOLD UP TIME (Typ.)| 40ms1230VAC
10ms/115VAC at full load
INPUT| VOLTAGE RANGE| 85 ∼ 305VAC
120 ∼ 430VDC
FREQUENCY RANGE| 47 ∼ 440Hz
EFFICIENCY (Typ.)| 74%| 78%| 82%| 82%| 83%
AC CURRENT (Typ.)| 0.35N115VAC 0.2A
230VAC 0.17Al277VAC
INRUSH CURRENT (Typ.)| COLD START 20N115VAC 40A/230VAC
LEAKAGE CURRENT| <0.25mA/277VAC
PROTECTION| OVERLOAD| 115%-190% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| 3.8 -4.95V| 5.75 – 6.75V| 13.8 -16.2V| 17.25 – 20.25V| 27.6 – 32.4V
Protection type: Shutoff o/p voltage, clamping by zener diode
ENVRONIENT| WORKING TEMP.| -30 – +70°C (Refer to °Derating Curve,
WORKING HUMIDITY| 20-90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 – +85°C, 10- 95% RH
TEMP. COEFFICIENT| ±0.03%1°C (0 -50°C )
VIBRATION| 10 – 500Hz, 5G 10mintIcycle, period for 60min. each along X, Y, Z axes
SOLDERING TEMPERATURE| Wave soldering: 265T2,5s (max.); Manual soldering: 390QC,3s (max.)
OPERATING ALTITUDE Nowa| 2000 meters
SAFETY &
EMC (Note.5)| SAFETY STANDARDS| IEC62368-1, UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004, BSMI CNS14336-1 approved
WITHSTAND VOLTAGE| IIP-OIP:3KVAC
ISOLATION RESISTANCE| I/P-0/P:100M Ohms / 500VDC /25 Cl 70% RH
EMC EMISSION| Parameter| Standard| Test Level/ Note
Conducted| BS EN/EN55032(CISPR32), CNS13438| Class B
Radiated| BS EN/EN55032(CISPR32), CNS13438| Class B
Harmonic Current (Note 5)| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3|
EMC IMMUNITY| BS EN/EN55035, BS EN/EN61000-6-2
Parameter| Standard| Test Level /Note
ESD| BS EN/EN61 000-4-2| Level 3, 8KV air; Level 2, 4KV contact, criteria A
Radiated Susceptibility| BS EN/EN61 000-4-3| Level 3, criteria A
EFT/Burest| BS EN/EN61000-4-4| Level 3, criteria A
Surge| BS EN/EN61000-4-5| Level 4,2KV/L-N, aiteria A
Conducted| BS EN/EN61 000-4-6| Level 3, criteria A
Magnetic Field| BS EN/EN61 000-4-8| Level 4, criteria A
Voltage Dips and interruptions| BS EN/EN61000-4-11| >95% dip O. 5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS| MTBF| 10656.2K hrs min. Telcordia SR-332 (Bell core) ; 970.3K hrs min. MIL-HDBK-217F (25°C)
DIMENSION| 52.427.224mm (LWH)
PACKING| 0.05Kg/240pcs/13Kg10.94CUFT
NOTE| 1. All parameters NOT specie ly mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 29MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 01 of & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The ambient temperature derating of 3.5t/1000m with fan less models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500f)
5. The power supply is considered as an independent unit ,but the final equipment still need to re-confirm that the whole system complies with the EMC cirectives. For guidance on how to perform these EMC tests, please refer to ‘EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
※ Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Block Diagram

MEAN WELL IRM 15 Series Mount Green Power Module - Block
Diagram

Derating Curve Output Derating VS Input Voltage

MEAN WELL IRM 15 Series Mount Green Power Module - Derating
Curve| MEAN WELL IRM 15
Series Mount Green Power Module - Input Voltage

Mechanical Specification

MEAN WELL IRM 15 Series Mount Green Power Module -
Figure

Installation Manual

Please refer to: http://www.meanwell.com/manual.html

https://www.meanwell.com/Upload/PDF/PCB_EN.pdf

File Name: IRM-15-SPEC
2023-02-20

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals