MEAN WELL LOP-400-12 5×3 Low Profile Open Frame Power Supply Instruction Manual

May 15, 2024
MEAN WELL

MEAN WELL LOP-400-12 5×3 Low Profile Open Frame Power Supply

Product Information

Specifications

MODEL DC VOLTAGE CURRENT RATED POWER OUTPUT
LOP-400-12 12V 23CFM Peak(3sec.) 600W, 399.6W Convection, 249.6W Ripple &

Noise (max.): 120mVp-p, Voltage Adj. Range:
11.4~12.6V
LOP-400-15| 15V| 33.3A| Peak(3sec.) 600W, 400.5W, 250.5W| Ripple & Noise (max.): 150mVp-p, Voltage Adj. Range:
14.3~15.8V

Product Usage Instructions

  • Setup and Installation
    • Ensure the input voltage range is compatible with your power source (80 ~ 264VAC, 113 ~ 370VDC).
    • Connect the output terminals of the power supply to your device following the correct polarity.
  • Power On/Off
    • To power on the unit, switch the power supply to the ON position. To turn it off, switch to the OFF position.
  • Troubleshooting
    • If you encounter any issues with the power supply, refer to the user manual for troubleshooting steps.

FAQs

  • Q: What is the input voltage range for the power supply?
    • A: The input voltage range is 80 ~ 264VAC and 113 ~ 370VDC.
  • Q: How do I adjust the output voltage?
    • A: The main output voltage can be adjusted within specific ranges mentioned in the specifications table.

MODEL| LOP-400-12| LOP-400-15| LOP-400-18| LOP-400-24| LOP-400-27| LOP-400-36| LOP-400-48| LOP-400-54
---|---|---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 12V| 15V| 18V| 24V| 27V| 36V| 48V| 54V
CURRENT| Peak(3sec.)| 50A| 40A| 33.3A| 25A| 22.2A| 16.7A| 12.5A| 11.1A
23CF M| 33.3A| 26.7A| 22.2A| 16.7A| 14.9A| 11.2A| 8.4A| 7.5A
Convection| 20.8A| 16.7A| 13.9A| 10.5A| 9.3A| 7.1A| 5.3A| 4.75A
RATED POWER| Peak(3sec.)| 600W| 600W| 599.4W| 600W| 599.4W| 601.2W| 600W| 599.4W
23CF M| 399.6W| 400.5W| 399.6W| 400.8W| 402.3W| 403.2W| 403.2W| 405W
Convection| 249.6W| 250.5W| 250.2W| 252W| 251.1W| 255.6W| 254.4W| 256.5W
RIPPLE & NOISE (max.) Note.2| 120mVp-p| 150mVp-p| 180mVp-p| 200mVp-p| 200mVp-p| 250mVp-p| 250mVp-p| 250mVp-p
VOLTAGE ADJ. RANGE

(MAIN OUTPUT)

| 11.4~12.6V| 14.3~15.8V| 17.1~18.9V| 22.8~25.2V| 25.6 ~ 28.4V| 34.2 ~37.8V| 45.6 ~50.4V| 52 ~58V
VOLTAGE TOLERANCE Note.3| ±3.0%| ±3.0%| ±3.0%| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
SETUP, RISE TIME| 1000ms, 30ms/230VAC         1500ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)| 30ms@250W load , 16ms@400W load
INPUT| VOLTAGE RANGE Note.4| 80 ~ 264VAC         113 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR| PF>0.95/230VAC PF>0.98/115VAC at full load
EFFICIENCY (Typ.)| 94%| 94.5%| 95%| 94.5%| 95%| 95%| 95%| 95%
AC CURRENT (Typ.)| 4.2A/115VAC         2.1A/230VAC
INRUSH CURRENT (Typ.)| COLD START 40A/115VAC         80A/230VAC
LEAKAGE CURRENT| Earth leakage current < 500μA(rms) @ 264VAC , touch current < 70μA(rms) @ 264VAC
PROTECTION| ****

OVERLOAD

| 105 ~ 150% rated output power, Protection type: Hiccup after 3 sec, recovers automatically after fault condition is removed


OVER VOLTAGE

| 13.2 ~ 15.6V| 16.5 ~ 19.5V| 19.8 ~ 23.4V| 26.4 ~ 31.2V| 29.7 ~ 35.1V| 39.6 ~ 46.8V| 52.8 ~ 62.4V| 59.4 ~ 67.5V
Protection type: Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Protection type: Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION| ****

EXTERNAL FAN SUPPLY

| 12V@0.5A for driving a fan / 12V@0.2A for without fan ; 23CFM

tolerance -15% ~+15% at main output 20% rated current

REMOTE SENSE| The remote sensing compensates for voltage drop on the load wiring up to 0.5V
POWER GOOD / POWER FAIL

(optional)

| 500ms>PG>10ms ; The TTL signal goes high with 10ms to 500ms delay after power set up ; The TTL signal goes low at least 1ms before Vo below 90% of rated value ; TTL(0 ~ 1V), TTH(2 ~ 5V)
ENVIRONMENT| WORKING TEMP.| -40 ~ +80℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, and Z axes

Features

MEAN-WELL-LOP-400-12-5×3-Low-Profile-Open-Frame-Power-Supply-fig-1
\(1\)

  • MEAN WELL Patent Number: ZL 202223277512.1
  • 5″×3″ compact size with low profile (27.5mm)
  • 80~264Vac input with PFC, No load power consumption<0.5W
  • Global certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1/-2-16)
  • 150%peak load @ 3s
  • 250W convection, 400W with FAN 23CM forced-cooled
  •  Suitable for Class I or Class I installations
  • Overvoltage category I (OVC Ш)
  • -40 ~ +80°C wide range operation temperature
  • High efficiency up to 95%
  •  Protections: Short circuit / Overload / Over voltage / Over temperature
  • Extremely low leakage current
  • Operating altitude up to 5000 meters
  • Built-in 12V/0.5A for external FAN
  • Built-in Remote sense
  • 3 years warranty

Applications

  • Industrial automation machinery
  • Industrial control system
  • Mechanical and electrical equipment
  • Electronic instruments, types of equipment or apparatus
  • Power sourcing equipment of PoE
  • Medical devices

GTIN CODE

Description

  • LOP-400 is a 400W highly reliable green PCB type low profile power supply with a high power density (24.6W/in’) on the 5″ by 3″ footprint.
  • It accepts 80~264VAC input and offers various output voltages between 12V and 54V. The working efficiency is up to 95% and the extremely low no-load power consumption is down below 0.5W.
  • LOP-400 can be used for both Class I (with FG) and Class II (no FG) system design. LOP-400 is equipped with complete protection functions;
  • It is complied with the international safety regulations such as IEC/BS EN/EN/UL62368-1, IEC/BS EN/EN60335-1, IEC/BS EN/EN61558-1/-2-16,
  • TEC/BS EN/EN60601-1.LOP-400 serves as a high-price-to-performance power supply solution for various industrial applications.
  • The extremely low leakage current is less than 500 mA. In addition, it conforms to the international medical regulations (2*MOPP) and EMC BS EN/EN55011, perfectly fitting all kinds of BF-rated “patient contact” medical system equipment.

Model Encoding

MEAN-WELL-LOP-400-12-5×3-Low-Profile-Open-Frame-Power-Supply-fig-1
\(2\)

SPECIFICATION

MODEL| LOP-400-12| LOP-400-15| LOP-400-18| LOP-400-24| LOP-400-27| LOP-400-36| LOP-400-48| LOP-400-54
---|---|---|---|---|---|---|---|---











OUTPUT

| DC VOLTAGE| 12V| 15V| 18V| 24V| 27V| 36V| 48V| 54V


CURRENT

| Peak(3sec.)| 50A| 40A| 33.3A| 25A| 22.2A| 16.7A| 12.5A| 11.1A
23CF M| 33.3A| 26.7A| 22.2A| 16.7A| 14.9A| 11.2A| 8.4A| 7.5A
Convection| 20.8A| 16.7A| 13.9A| 10.5A| 9.3A| 7.1A| 5.3A| 4.75A


RATED POWER

| Peak(3sec.)| 600W| 600W| 599.4W| 600W| 599.4W| 601.2W| 600W| 599.4W
23CF M| 399.6W| 400.5W| 399.6W| 400.8W| 402.3W| 403.2W| 403.2W| 405W
Convection| 249.6W| 250.5W| 250.2W| 252W| 251.1W| 255.6W| 254.4W| 256.5W
RIPPLE & NOISE (max.) Note.2| 120mVp-p| 150mVp-p| 180mVp-p| 200mVp-p| 200mVp-p| 250mVp-p| 250mVp-p| 250mVp-p
VOLTAGE ADJ. RANGE

(MAIN OUTPUT)

| 11.4~12.6V| 14.3~15.8V| 17.1~18.9V| 22.8~25.2V| 25.6 ~ 28.4V| 34.2 ~37.8V| 45.6 ~50.4V| 52 ~58V
VOLTAGE TOLERANCE Note.3| ±3.0%| ±3.0%| ±3.0%| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
SETUP, RISE TIME| 1000ms, 30ms/230VAC         1500ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)| 30ms@250W load , 16ms@400W load





INPUT

| VOLTAGE RANGE Note.4| 80 ~ 264VAC         113 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR| PF>0.95/230VAC PF>0.98/115VAC at full load
EFFICIENCY (Typ.)| 94%| 94.5%| 95%| 94.5%| 95%| 95%| 95%| 95%
AC CURRENT (Typ.)| 4.2A/115VAC         2.1A/230VAC
INRUSH CURRENT (Typ.)| COLD START 40A/115VAC         80A/230VAC
LEAKAGE CURRENT| Earth leakage current < 500μA(rms) @ 264VAC , touch current < 70μA(rms) @ 264VAC



PROTECTION

| ****

OVERLOAD

| 105 ~ 150% rated output power, Protection type: Hiccup after 3 sec, recovers automatically after fault condition is removed


OVER VOLTAGE

| 13.2 ~ 15.6V| 16.5 ~ 19.5V| 19.8 ~ 23.4V| 26.4 ~ 31.2V| 29.7 ~ 35.1V| 39.6 ~ 46.8V| 52.8 ~ 62.4V| 59.4 ~ 67.5V
Protection type: Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Protection type: Shut down o/p voltage, recovers automatically after temperature goes down




FUNCTION

| ****

EXTERNAL FAN SUPPLY

| 12V@0.5A for driving a fan / 12V@0.2A for without fan ; 23CFM

tolerance -15% ~+15% at main output 20% rated current

REMOTE SENSE| The remote sensing compensates for voltage drop on the load wiring up to 0.5V
POWER GOOD / POWER FAIL

(optional)

| 500ms>PG>10ms ; The TTL signal goes high with 10ms to 500ms delay after power set up ; The TTL signal goes low at least 1ms before Vo below 90% of rated value ; TTL(0 ~ 1V), TTH(2 ~ 5V)




ENVIRONMENT

| WORKING TEMP.| -40 ~ +80℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along the X, Y, and Z axes

MEAN-WELL-LOP-400-12-5×3-Low-Profile-Open-Frame-Power-Supply-fig-1
\(7\)

Block Diagram

MEAN-WELL-LOP-400-12-5×3-Low-Profile-Open-Frame-Power-Supply-fig-1
\(3\)

Derating Curve

MEAN-WELL-LOP-400-12-5×3-Low-Profile-Open-Frame-Power-Supply-fig-1
\(4\)

AMBIENT TEMPERATURE (℃)

Cooling Max. Output Power
Free air convection 250W
Force-cooled with external Fan 400W

Output Derating VS Input Voltage

MEAN-WELL-LOP-400-12-5×3-Low-Profile-Open-Frame-Power-Supply-fig-1
\(5\)

Mechanical Specification

MEAN-WELL-LOP-400-12-5×3-Low-Profile-Open-Frame-Power-Supply-fig-1
\(6\)

AC Input Connector (CN1): JST B3P-VH or equivalent

Pin No. Assignment Mating Housing Terminal
1 AC/L JST VHR or equivalent JST SVH-21T-P1.1 or equivalent
2 No Pin
3 AC/N

FAN Connector(CN2): TKP 8812-2 or equivalent

Pin No. Assignment Mating Housing Terminal
1 DC COM TKP 2502

or equivalent

| TKP 8811

or equivalent

2| +12V

Note:

  • Class Ⅰ System: Mounting holes marked with have to be connected to safety earth.
  • Class Ⅱ System: Unnecessary to connect with Safety Earth.
    • HS1,HS2,HS3,HS4 can not be shorted

DC Output Connector

Assignment Output Terminals
-V M3.5 Pan HD screw in 2 positions Torque to 8 lbs-in(90cNm)max.

+V

Installation Manual